1.
Clin Chem Lab Med ; 62(7): 1411-1420, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38217085

RESUMO

OBJECTIVES: Lymphocyte subsets are the predictors of disease diagnosis, treatment, and prognosis. Determination of lymphocyte subsets is usually carried out by flow cytometry. Despite recent advances in flow cytometry analysis, most flow cytometry data can be challenging with manual gating, which is labor-intensive, time-consuming, and error-prone. This study aimed to develop an automated method to identify lymphocyte subsets. METHODS: We propose a knowledge-driven combined with data-driven method which can gate automatically to achieve subset identification. To improve accuracy and stability, we have implemented a Loop Adjustment Gating to optimize the gating result of the lymphocyte population. Furthermore, we have incorporated an anomaly detection mechanism to issue warnings for samples that might not have been successfully analyzed, ensuring the quality of the results. RESULTS: The evaluation showed a 99.2 % correlation between our method results and manual analysis with a dataset of 2,000 individual cases from lymphocyte subset assays. Our proposed method attained 97.7 % accuracy for all cases and 100 % for the high-confidence cases. With our automated method, 99.1 % of manual labor can be saved when reviewing only the low-confidence cases, while the average turnaround time required is only 29 s, reducing by 83.7 %. CONCLUSIONS: Our proposed method can achieve high accuracy in flow cytometry data from lymphocyte subset assays. Additionally, it can save manual labor and reduce the turnaround time, making it have the potential for application in the laboratory.


Assuntos
Citometria de Fluxo , Subpopulações de Linfócitos , Subpopulações de Linfócitos/classificação , Subpopulações de Linfócitos/citologia , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Automação Laboratorial , Reprodutibilidade dos Testes , Humanos
2.
World J Microbiol Biotechnol ; 40(7): 222, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38811387

RESUMO

In this study, it was aimed to investigate bacterial contamination in apheresis platelet suspensions (APS) by automated blood culture system and flow cytometry method (FCM).33 spiked APS each using 11 bacterial strains (5 standard strains, 6 clinical isolates), were prepared in three different dilutions (1-10, 10-50, 50-100 cfu/mL), incubated in two different temperatures (35-37 °C and 22-24 °C) and different incubation times (18-96 h) evaluated by FCM. This three different dilutions were also inoculated into special platelet culture bottles (BacT/ALERT® BPA) and loaded into the blood culture system. Additionally 80 APSs routinely prepared in the Transfusion Center were evaluated by both FCM and the blood culture system. Platelets were lysed by freeze-thaw method.All spiked samples were positive with BacT/ALERT® BPA in 12-18 h. In 96 h incubation at 22-24 °C, the presence of bacteria was detected by FCM in all other samples (31/33) except low dilutions (1-10 and 10-100 CFU/ml) of K.pneumoniae standard strain. In the 35-37 °C, the presence of bacteria was detected by FCM in all samples (33/33) after 48 h of incubation. In routine APS one sample detected as positive (Bacillus simplex) with BacT/ALERT® BPA and no positivity was detected by FCM.The freeze-thaw method, which we have optimized for the lysis of platelets, is very practical and can be easily applied. The BacT/ALERT® system has been found to be very sensitive in detecting bacterial contamination in PSs. Flow cytometry method has been found to be successful, fast, easy to use and low cost in detecting bacterial contamination in PSs.


Assuntos
Plaquetas , Segurança do Sangue , Citometria de Fluxo , Segurança do Sangue/instrumentação , Segurança do Sangue/métodos , Plaquetas/microbiologia , Citometria de Fluxo/normas , Remoção de Componentes Sanguíneos , Hemocultura/normas , Bactérias/isolamento & purificação , Humanos , Sensibilidade e Especificidade
3.
Br J Haematol ; 196(2): 374-379, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34476808

RESUMO

High-sensitivity multicolour flow cytometry (MFC)-based B-lymphoblastic leukaemia (B-ALL) measurable residual disease (BMRD) assay is increasingly being used in clinical practice. Herein, we describe six consistently present low-level populations immunophenotypically mimicking abnormal B-ALL blasts in 441 BMRD samples from 301 children. These included CD19+ CD123+ plasmacytoid dendritic cells differentiating from lymphoid precursors, CD10+ transitional B cells with CD10+ /CD38dim-to-negative/CD20bright/CD45bright phenotype, CD19+ natural killer (NK) cells, CD73bright/CD10+ mesenchymal stromal/stem cells, CD73bright/CD34+ endothelial cells, and a CD34+ CD38dim-to-negative/CD10- /CD20bright/CD45bright subset of mature B cells. We provide the proportions, comprehensive immunophenotype, and practical clues for proper identification of these low-level populations. Knowledge regarding the presence and immunophenotype of these mimics is essential for accurate interpretation in high-sensitivity MFC-BMRD analysis.


Assuntos
Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Neoplasia Residual/diagnóstico , Leucemia-Linfoma Linfoblástico de Células Precursoras B/diagnóstico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Artefatos , Biomarcadores Tumorais , Tomada de Decisão Clínica , Gerenciamento Clínico , Citometria de Fluxo/normas , Humanos , Imunofenotipagem/normas , Quimioterapia de Indução , Leucemia-Linfoma Linfoblástico de Células Precursoras B/etiologia , Leucemia-Linfoma Linfoblástico de Células Precursoras B/terapia , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
5.
Rev Med Virol ; 31(3): e2181, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33152146

RESUMO

This study aimed to assess the diagnostic test accuracy (DTA) of severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) serological test methods and the kinetics of antibody positivity. Systematic review and meta-analysis were conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline. We included articles evaluating the diagnostic accuracy of serological tests and the kinetics of antibody positivity. MEDLINE through PubMed, Scopus, medRxiv and bioRxiv were sources of articles. Methodological qualities of included articles were appraised using QUADAS-2 while Metandi performs bivariate meta-analysis of DTA using a generalized linear mixed-model approach. Stata 14 and Review Manager 5.3 were used for data analysis. The summary sensitivity/specificity of chemiluminescence immunoassay (CLIA), enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay (LFIA) were 92% (95% CI: 86%-95%)/99% (CI: 97%-99%), 86% (CI: 82%-89%)/99% (CI: 98%-100%) and 78% (CI: 71%-83%)/98% (95% CI: 96%-99%), respectively. Moreover, CLIA-based assays produced nearly 100% sensitivity within 11-15 days post-symptom onset (DPSO). Based on antibody type, the sensitivity of ELISA-total antibody, CLIA-IgM/G and CLIA-IgG gauged at 94%, 92% and 92%, respectively. The sensitivity of CLIA-RBD assay reached 96%, while LFIA-S demonstrated the lowest sensitivity, 71% (95% CI: 58%-80%). CLIA assays targeting antibodies against RBD considered the best DTA. The antibody positivity rate increased corresponding with DPSO, but there was some decrement when moving from acute phase to convalescent phase of infection. As immunoglobulin isotope-related DTA was heterogeneous, our data have insufficient evidence to recommend CLIA/ELISA for clinical decision-making, but likely to have comparative advantage over RT-qPCR in certain circumstances and geographic regions.


Assuntos
Teste Sorológico para COVID-19/normas , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática/normas , Citometria de Fluxo/normas , Medições Luminescentes/normas , SARS-CoV-2/patogenicidade , Anticorpos Antivirais/sangue , COVID-19/epidemiologia , COVID-19/imunologia , COVID-19/virologia , Teste Sorológico para COVID-19/métodos , Convalescença , Humanos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Índice de Gravidade de Doença
6.
Int J Mol Sci ; 23(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35055086

RESUMO

Chimeric-antigen-receptor (CAR)-T-cell therapy is already widely used to treat patients who are relapsed or refractory to chemotherapy, antibodies, or stem-cell transplantation. Multiple myeloma still constitutes an incurable disease. CAR-T-cell therapy that targets BCMA (B-cell maturation antigen) is currently revolutionizing the treatment of those patients. To monitor and improve treatment outcomes, methods to detect CAR-T cells in human peripheral blood are highly desirable. In this study, three different detection reagents for staining BCMA-CAR-T cells by flow cytometry were compared. Moreover, a quantitative polymerase chain reaction (qPCR) to detect BCMA-CAR-T cells was established. By applying a cell-titration experiment of BCMA-CAR-T cells, both methods were compared head-to-head. In flow-cytometric analysis, the detection reagents used in this study could all detect BCMA-CAR-T cells at a similar level. The results of false-positive background staining differed as follows (standard deviation): the BCMA-detection reagent used on the control revealed a background staining of 0.04% (±0.02%), for the PE-labeled human BCMA peptide it was 0.25% (±0.06%) and for the polyclonal anti-human IgG antibody it was 7.2% (±9.2%). The ability to detect BCMA-CAR-T cells down to a concentration of 0.4% was similar for qPCR and flow cytometry. The qPCR could detect even lower concentrations (0.02-0.01%). In summary, BCMA-CAR-T-cell monitoring can be reliably performed by both flow cytometry and qPCR. In flow cytometry, reagents with low background staining should be preferred.


Assuntos
Antígeno de Maturação de Linfócitos B/metabolismo , Citometria de Fluxo , Reação em Cadeia da Polimerase , Receptores de Antígenos Quiméricos/metabolismo , Linfócitos T/metabolismo , Antígeno de Maturação de Linfócitos B/genética , Biomarcadores , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Imunofenotipagem , Imunoterapia Adotiva/métodos , Imunoterapia Adotiva/normas , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Reação em Cadeia da Polimerase em Tempo Real , Receptores de Antígenos Quiméricos/genética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Linfócitos T/imunologia
7.
Br J Haematol ; 193(5): 922-927, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33161592

RESUMO

Given its myeloid-restricted expression, myeloperoxidase (MPO) is typically used for lineage assignment (myeloid vs. lymphoid) during acute leukaemia (AL) diagnostics. In the present study, a robust flow cytometric definition for MPO positivity was established based on the standardised EuroFlow protocols, the standardised Acute Leukaemia Orientation Tube and 1734 multicentre AL cases (with confirmed assay stability). The best diagnostic performance was achieved by defining MPO positivity as ≥20% of the AL cells exceeding a lymphocyte-based threshold. The methodology employed should be applicable to any form of standardised flow cytometry.


Assuntos
Citometria de Fluxo/normas , Imunofenotipagem/normas , Leucemia , Proteínas de Neoplasias , Peroxidase , Doença Aguda , Feminino , Humanos , Leucemia/diagnóstico , Leucemia/enzimologia , Leucemia/imunologia , Masculino , Proteínas de Neoplasias/sangue , Proteínas de Neoplasias/imunologia , Peroxidase/sangue , Peroxidase/imunologia
8.
Cytometry A ; 99(1): 60-67, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33197114

RESUMO

Data management is essential in a flow cytometry (FCM) shared resource laboratory (SRL) for the integrity of collected data and its long-term preservation, as described in the Cytometry publication from 2016, ISAC Flow Cytometry Shared Resource Laboratory (SRL) Best Practices (Barsky et al.: Cytometry Part A 89A(2016): 1017-1030). The SARS-CoV-2 pandemic introduced an array of challenges in the operation of SRLs. The subsequent laboratory shutdowns and access restrictions brought to the forefront well-established practices that withstood the impact of a sudden change in operations and illuminated areas that need improvement. The most significant challenges from a data management perspective were data access for remote analysis and workstation management. Notably, lessons learned from this challenge emphasize the importance of safeguarding collected data from loss in various emergencies such as fire or natural disasters where the physical hardware storing data could be directly affected. Here, we describe two data management systems that have been successful during the current emergency created by the pandemic, specifically remote access and automated data transfer. We will discuss other situations that could arise and lead to data loss or challenges in interpreting data. © 2020 International Society for Advancement of Cytometry.


Assuntos
COVID-19/epidemiologia , Gerenciamento de Dados/tendências , Citometria de Fluxo/tendências , Laboratórios/tendências , Teletrabalho/tendências , COVID-19/prevenção & controle , Gerenciamento de Dados/normas , Citometria de Fluxo/normas , Humanos , Laboratórios/normas , Teletrabalho/normas
9.
Cytometry A ; 99(1): 51-59, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33197144

RESUMO

The COVID-19 pandemic has dramatically affected shared resource lab (SRL) staff in-person availability at institutions globally. This article discusses the challenges of ensuring reliable instrument performance and quality data output while facility staff and external service provider on-site presence is severely limited. Solutions revolve around the adoption of remote monitoring and troubleshooting platforms, provision of self-service troubleshooting resources specific to facility instruments and workflows, development of an assistance contact policy, and ensuring efficiency of limited in-person staff time. These solutions employ software and hardware tools that are already in use or readily available in the SRL community, such as remote instrument access tools, video hosting and conferencing platforms, and ISAC shared resources. © 2020 International Society for Advancement of Cytometry.


Assuntos
COVID-19/epidemiologia , Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Laboratórios/normas , Controle de Qualidade , Teletrabalho/normas , COVID-19/prevenção & controle , Citometria de Fluxo/tendências , Humanos , Laboratórios/tendências , Teletrabalho/tendências , Webcasts como Assunto/normas , Webcasts como Assunto/tendências , Fluxo de Trabalho
10.
Cytometry A ; 99(1): 90-99, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33118310

RESUMO

In March 2020, with lockdown due to the coronavirus pandemic underway, the Francis Crick Institute (the Crick) regeared its research laboratories into clinical testing facilities. Two pipelines were established, one for polymerase chain reaction and the other for Serology. This article discusses the Cricks Flow Cytometry Science Technology Platform (Flow STP) role in setting up the Serology pipeline. Pipeline here referring to the overarching processes in place to facilitate the receipt of human sera through to a SARs-CoV-2 enzyme-linked immunosorbent assay result. We examine the challenges that had to be overcome by a research laboratory to incorporate clinical diagnostics and the processes by which this was achieved. It describes the governance required to run the service, the design of the standard operating procedures (SOPs) and pipeline, the setting up of the assay, the validation required to show the robustness of the pipeline and reporting the results of the assay. Finally, as the lockdown started to ease in June 2020, it examines how this new service affects the daily running of the Flow STP. © 2020 The Authors. Cytometry Part A published by Wiley Periodicals LLC on behalf of International Society for Advancement of Cytometry.


Assuntos
Adaptação Psicológica , COVID-19/diagnóstico , Citometria de Fluxo/normas , Laboratórios/normas , SARS-CoV-2/isolamento & purificação , COVID-19/sangue , COVID-19/epidemiologia , Ensaio de Imunoadsorção Enzimática/normas , Ensaio de Imunoadsorção Enzimática/tendências , Citometria de Fluxo/tendências , Humanos , Laboratórios/tendências , Reprodutibilidade dos Testes
11.
Cytotherapy ; 23(1): 77-87, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32718876

RESUMO

BACKGROUND AIMS: Adoptive cellular therapy with immune effector cells (IECs) has shown promising efficacy against some neoplastic diseases as well as potential in immune regulation. Both inherent variability in starting material and variations in cell composition produced by the manufacturing process must be thoroughly evaluated with a validated method established to quantify viable lymphocyte subtypes. Currently, commercialized immunophenotyping methods determine cell viability with significant errors in thawed products since they do not include any viability staining. We hereby report on the validation of a flow cytometry-based method for quantifying viable lymphocyte immunophenotypes in fresh and cryopreserved hematopoietic cellular products. METHODS: Using fresh or frozen cellular products and stabilized blood, we report on the validation parameters accuracy, uncertainty, precision, sensitivity, robustness and contamination between samples for quantification of viable CD3+, CD4+ T cells, CD8+ T cells, CD3-CD56+CD16+/- NK cells, CD19+ B cells and CD14+ monocytes of relevance to fresh and cryopreserved hematopoietic cellular products using the Cytomics FC500 cytometer (Beckman Coulter). RESULTS: The acceptance criteria set in the validation plan were all met. The method is able to accommodate the variability in absolute numbers of cells in starting materials collected or cryopreserved from patients or healthy donors (uncertainty of ≤20% at three different concentrations), stability over time (compliance over 3 years during regular inter-laboratory comparisons) and confidence in meaningful changes during cell processing and manufacturing (intra-assay and intermediate precision of 10% coefficient of variation). Furthermore, the method can accurately report on the efficacy of cell depletion since the lower limit of quantification was established (CD3+, CD4+ and CD8+ cells at 9, 8 and 8 cells/µL, respectively). The method complies with Foundation for the Accreditation of Cellular Therapy (FACT) standards for IEC, FACT-Joint Accreditation Committee of ISCT-EBMT (JACIE) hematopoietic cell therapy standards, International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use Q2(R1) and International Organization for Standardization 15189 standards. Furthermore, it complies with Ligand Binding Assay Bioanalytical Focus Group/American Association of Pharmaceutical Scientists, International Council for Standardization of Hematology/International Clinical Cytometry Society and European Bioanalysis Forum recommendations for validating such methods. CONCLUSIONS: The implications of this effort include standardization of viable cell immunophenotyping of starting material for cell manufacturing, cell selection and in-process quality controls or dosing of IECs. This method also complies with all relevant standards, particularly FACT-JACIE standards, in terms of enumerating and reporting on the viability of the "clinically relevant cell populations."


Assuntos
Linfócitos B/classificação , Criopreservação , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Subpopulações de Linfócitos T/classificação , Adulto , Linfócitos B/metabolismo , Humanos , Imunofenotipagem , Masculino , Reprodutibilidade dos Testes
12.
Malar J ; 20(1): 57, 2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33478496

RESUMO

Drug-resistant Plasmodium is a frequent global threat in malaria eradication programmes, highlighting the need for new anti-malarial drugs and efficient detection of treatment failure. Plasmodium falciparum culture is essential in drug discovery and resistance surveillance. Microscopy of Giemsa-stained erythrocytes is common for determining anti-malarial effects on the intraerythrocytic development of cultured Plasmodium parasites. Giemsa-based microscopy use is conventional but laborious, and its accuracy depends largely on examiner skill. Given the availability of nucleic acid-binding fluorescent dyes and advances in flow cytometry, the use of various fluorochromes has been frequently attempted for the enumeration of parasitaemia and discrimination of P. falciparum growth in drug susceptibility assays. However, fluorochromes do not meet the requirements of being fast, simple, reliable and sensitive. Thus, this review revisits the utility of fluorochromes, notes previously reported hindrances, and highlights the challenges and opportunities for using fluorochromes in flow cytometer-based drug susceptibility tests. It aims to improve drug discovery and support a resistance surveillance system, an essential feature in combatting malaria.


Assuntos
Antimaláricos/farmacologia , Citometria de Fluxo/métodos , Fluorescência , Testes de Sensibilidade Parasitária/métodos , Plasmodium falciparum/efeitos dos fármacos , Eritrócitos/parasitologia , Citometria de Fluxo/normas , Corantes Fluorescentes/normas , Testes de Sensibilidade Parasitária/normas , Coloração e Rotulagem
13.
J Clin Lab Anal ; 35(11): e23834, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34636443

RESUMO

BACKGROUND: Flow cytometry is a powerful technique that provides information regarding cell properties. In this study, we evaluated the analytical performance of a new flow cytometer, the 10-color BD FACSLyricTM , which could help doctors obtain reliable test results prior to clinical research. METHODS: We used SpheroTM Rainbow Calibration Particles and the SpheroTM Nano Fluorescent Particle Size Standard Kit to validate the fluorescence sensitivity and linearity. The Beckman Coulter IMMUNO-TROL Cell was used as the quality control to evaluate the accuracy and reproducibility of surface markers detected by the flow cytometer. Furthermore, BD Calibrate APC Beads and CS&T Research Beads were applied to calculate the carry-over contamination rate and assess the instrument stability. RESULTS: A linear regression equation between the molecules of equivalent soluble fluorochrome and fluorescence detection limit showed a good linear fit (R2  > 0.99). The minimum bead size detected by side scatter was 0.22 µm. The coefficient of variation percentage of each fluorescence channel was below 2%, and the carry-over contamination rate of the cytometer was under 0.2%. After running the BD FACSLyricTM cytometer continuously for 8 h, the median fluorescence index of particles remained close to that at the time of cytometer startup. CONCLUSIONS: The 10-color BD FACSLyricTM cytometer showed good performance in the evaluation performed in this study and may be trusted to provide accurate results for clinical research.


Assuntos
Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Animais , Humanos , Limite de Detecção , Modelos Lineares , Subpopulações de Linfócitos/citologia , Reprodutibilidade dos Testes
14.
J Clin Lab Anal ; 35(1): e23586, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32969530

RESUMO

BACKGROUND: Automated flow cytometry-based urine analyzer is increasingly being used to identify and enumerate cells and particles in urine specimens. It measures electrical conductivity which could be transformed to osmolality. Using this machine, all urine specimens could be screened for osmolality without requiring a separate dedicated device. We evaluated the performance of the new instrument, the UF-5000 (Sysmex Corporation), in the measurement of urine osmolality. METHODS: The precision of urine osmolality measurement by the UF-5000 was evaluated for 20 days and 4 times a day for 2 concentrations. The linearity and detection capability were evaluated according to the Clinical and Laboratory Standards Institute guidelines. For comparison, 270 random urine specimens from patients were tested simultaneously using the UF5000 and the OsmoPro micro-osmometer (Advanced instruments). RESULTS: The laboratory-based coefficient variations were less than 5%. Urine osmolality using the UF-5000 has a verified linear range (y = 1.097x + 16.91, R2  = .997). Within the comparison analysis, the mean difference was not large (-7.72%) but each differences were largely dispersed with 95% limits of agreement (LoA) from -70.5 to 55.06%, and the mean absolute difference -28.3 mOsm/kg with 95% LoA from -295.13 to 238.45 mOsm/kg. Cohen's kappa value was 0.54 (95% CI, 0.45-0.63). CONCLUSIONS: The UF-5000 measured conductivity and generated an acceptable quantitative analysis of urine osmolality. When compared with the results of the freezing point depression method used by the OsmoPro, a percentage of the measured urine osmolality by the UF-5000 was outside the allowable limit.


Assuntos
Automação Laboratorial , Citometria de Fluxo , Urinálise , Automação Laboratorial/métodos , Automação Laboratorial/normas , Condutividade Elétrica , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Humanos , Concentração Osmolar , Urinálise/métodos , Urinálise/normas , Urina/química , Urina/citologia
15.
Int J Mol Sci ; 22(15)2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-34361020

RESUMO

A stochastic model of the flow cytometer measurement process was developed to assess the nature of the observed coefficient of variation (CV%) of the mean fluorescence intensity (MFI) from a population of labeled microspheres (beads). Several sources of variability were considered: the total number of labels on a bead, the path through the laser beam, the optical absorption cross-section, the quantum yield, the numerical aperture of the collection optics, and the photoelectron conversion efficiency of the photomultiplier (PMT) cathode. The variation in the number of labels on a bead had the largest effect on the CV% of the MFI of the bead population. The variation in the path of the bead through the laser beam was minimized using flat-top lasers. The variability in the average optical properties of the labels was of minor importance for beads with sufficiently large number of labels. The application of the bead results to the measured CV% of labeled B cells indicated that the measured CV% was a reliable measure of the variability of antibodies bound per cell. With some modifications, the model can be extended to multicolor flow cytometers and to the study of CV% from cells with low fluorescence signal.


Assuntos
Linfócitos B/citologia , Citometria de Fluxo/normas , Microesferas , Análise de Variância , Citometria de Fluxo/métodos , Humanos , Reprodutibilidade dos Testes , Processos Estocásticos
16.
Eur J Immunol ; 49(10): 1457-1973, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31633216

RESUMO

These guidelines are a consensus work of a considerable number of members of the immunology and flow cytometry community. They provide the theory and key practical aspects of flow cytometry enabling immunologists to avoid the common errors that often undermine immunological data. Notably, there are comprehensive sections of all major immune cell types with helpful Tables detailing phenotypes in murine and human cells. The latest flow cytometry techniques and applications are also described, featuring examples of the data that can be generated and, importantly, how the data can be analysed. Furthermore, there are sections detailing tips, tricks and pitfalls to avoid, all written and peer-reviewed by leading experts in the field, making this an essential research companion.


Assuntos
Alergia e Imunologia/normas , Separação Celular/métodos , Separação Celular/normas , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Consenso , Humanos , Fenótipo
17.
Transfusion ; 60(5): 1032-1041, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32237236

RESUMO

BACKGROUND: Great deformability allows red blood cells (RBCs) to flow through narrow capillaries in tissues. A number of microfluidic devices with capillary-like microchannels have been developed to monitor storage-related impairment of RBC deformability during blood banking operations. This proof-of-concept study describes a new method to standardize and improve reproducibility of the RBC deformability measurements using one of these devices. STUDY DESIGN AND METHODS: The rate of RBC flow through the microfluidic capillary network of the microvascular analyzer (MVA) device made of polydimethylsiloxane was measured to assess RBC deformability. A suspension of microbeads in a solution of glycerol in phosphate-buffered saline was developed to be used as an internal flow rate reference alongside RBC samples in the same device. RBC deformability and other in vitro quality markers were assessed weekly in six leukoreduced RBC concentrates (RCCs) dispersed in saline-adenine-glucose-mannitol additive solution and stored over 42 days at 4°C. RESULTS: The use of flow reference reduced device-to-device measurement variability from 10% to 2%. Repeated-measure analysis using the generalized estimating equation (GEE) method showed a significant monotonic decrease in relative RBC flow rate with storage from Week 0. By the end of storage, relative RBC flow rate decreased by 22 ± 6% on average. CONCLUSIONS: The suspension of microbeads was successfully used as a flow reference to increase reproducibility of RBC deformability measurements using the MVA. Deformability results suggest an early and late aging phase for stored RCCs, with significant decreases between successive weeks suggesting a highly sensitive measurement method.


Assuntos
Deformação Eritrocítica/fisiologia , Eritrócitos/citologia , Eritrócitos/fisiologia , Dispositivos Lab-On-A-Chip/normas , Técnicas Analíticas Microfluídicas , Bancos de Sangue/normas , Velocidade do Fluxo Sanguíneo/fisiologia , Preservação de Sangue/efeitos adversos , Preservação de Sangue/métodos , Preservação de Sangue/normas , Criopreservação , Contagem de Eritrócitos/instrumentação , Contagem de Eritrócitos/métodos , Contagem de Eritrócitos/normas , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Hemólise , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/normas , Estudo de Prova de Conceito , Reprodutibilidade dos Testes , Fatores de Tempo , Armazenamento de Sangue/métodos
18.
Acta Haematol ; 143(2): 140-145, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31330512

RESUMO

BACKGROUND: Myelodysplastic syndromes (MDS) and idiopathic cytopenia of undetermined significance (ICUS) are heterogeneous hematological disorders characterized by hematopoietic dysplasia and/or chromosomal aberrancy. OBJECTIVES: This study aimed to evaluate the diagnostic value of flow cytometry standardized using the European LeukemiaNet (ELN) for MDS and ICUS by analyzing samples obtained from patients with cytopenia based on morphological examination, cytogenetic analysis, and flow cytometry. METHODS: We retrospectively analyzed bone marrow samples aspirated from 253 consecutive patients (median age: 66 years [range: 1-92]) to identify the cause of cytopenia. RESULTS: Sixty patients presented with MDS, and 16 with ICUS. MDS subtypes were distributed as follows: MDS with single-lineage dysplasia (n = 10); MDS with multi-lineage dysplasia (n = 10); MDS with ringed sideroblasts (n = 4); MDS with excess blasts-1 (n = 9); MDS with excess blasts-2 (n = 13), MDS unclassified (n = 5); 5q-syndrome (n = 6); and MDS/myeloproliferative neoplasms (n = 3). Four representative ELN indexes were used. Two or more ELN MDS indexes were in the abnormal range in 35 MDS cases (58.3%) and 4 ICUS cases (25.0%). CONCLUSIONS: Morphological examination remains the standard for MDS diagnosis. Considering the low incidence of genetically proven ICUS (20.2-27.5%), the low sensitivity of ELN MDS indexes for ICUS is considered a valuable alternative.


Assuntos
Células da Medula Óssea/metabolismo , Citometria de Fluxo/normas , Síndromes Mielodisplásicas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Células da Medula Óssea/citologia , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
19.
BMC Vet Res ; 16(1): 230, 2020 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-32631319

RESUMO

BACKGROUND: In the poultry industry, quantitative analysis of chicken T cell proliferation is important in many biological applications such as drug screening, vaccine production, and cytotoxicity assessment. Several assays have been established to evaluate this immunological response in chicken cells. However, these assays have some disadvantages including use of radioactive labels ([3H]-Thymidine assay), necessity of DNA denaturation or digestion (BrdU incorporation assay), lack of sensitivity and underestimation of anti-proliferative effects (MTT assay), and modulation of activation molecules and cell viability reduction (CFSE assay). Overcoming these limitations, the EdU proliferation assay is sensitive and advantageous compared to [3H]-Thymidine radioactive labels in studies on cell proliferation in vitro and allows simultaneous identification of T cell populations. However, this assay has not been established using primary chicken cells to evaluate T cell proliferation by flow cytometry. RESULTS: Here, we established an assay to evaluate the proliferation of primary chicken splenocytes based on the incorporation of a thymidine analog (EdU) and a click reaction with a fluorescent azide, detected by a flow cytometer. We also established a protocol that combines EdU incorporation and immunostaining to detect CD4+ and CD8+ proliferating T cells. By inducing cell proliferation with increasing concentrations of a mitogen (Concanavalin A), we observed a linear increase in EdU positive cells, indicating that our protocol does not present any deficiency in the quantity and quality of reagents that were used to perform the click reaction. CONCLUSIONS: In summary, we established a reliable protocol to evaluate the proliferation of CD4+ and CD8+ chicken T cells by flow cytometry. Moreover, as this is an in-house protocol, the cost per sample using this protocol is low, allowing its implementation in laboratories that process a large number of samples.


Assuntos
Galinhas , Citometria de Fluxo/veterinária , Linfócitos T/citologia , Animais , Proliferação de Células , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Timidina/análogos & derivados , Timidina/química
20.
J Clin Lab Anal ; 34(9): e23361, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32430992

RESUMO

BACKGROUND: Multiparameter flow cytometry is the preferred method to determine immunophenotypic features of cells present in a wide variety of sample types. Standardization is key to avoid inconsistencies and subjectivity of interpretations between clinical diagnostic laboratories. Among these standardization requirements, synchronization between different flow cytometer instruments is indispensable to obtain comparable results. This study aimed to investigate whether two widely used flow cytometers, the FACSCanto II and LSRFortessa, can be effectively synchronized utilizing calibration bead-based synchronization. METHOD: Two FACSCanto II and two LSRFortessa flow cytometers were synchronized with both multicolor hard-dyed and single-fluorochrome-conjugated surface-dyed beads according to the manufacturer's instructions. Cell staining was performed on five whole-blood samples obtained from healthy controls and were analyzed upon synchronization with the respective synchronization protocols. RESULTS: Comparability criteria (defined as <15% deviation from the reference instrument) were met with both bead sets when synchronizing different FACSCanto II or LSRFortessa instruments. However, we observed that the criteria could not be met when synchronizing FACSCanto II with LSRFortessa instruments with multicolor hard-dyed beads. By utilizing single-fluorochrome-conjugated surface-dyed beads to determine and adjust PMT voltages, the accepted comparability criteria were successfully met. The protocol has been validated using five different eight-parameter stained samples. CONCLUSION: We show that FACSCanto II and LSRFortessa instruments can effectively be synchronized using single-fluorochrome-conjugated surface-dyed beads in case deviation criteria cannot be met using multicolor hard-dyed beads. Synchronization with single-fluorochrome-conjugated surface-dyed beads results in decreased deviations between instruments, allowing comparability criteria to become stricter.


Assuntos
Serviços de Laboratório Clínico/normas , Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Corantes Fluorescentes/química , Imunofenotipagem/normas , Calibragem , Citometria de Fluxo/métodos , Voluntários Saudáveis , Humanos