Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.121
Filtrar
Mais filtros

Coleção SES
Intervalo de ano de publicação
1.
Gastroenterology ; 165(2): 473-482.e2, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37121331

RESUMO

BACKGROUND & AIMS: Several studies have compared primary endoscopic ultrasound (EUS)-guided biliary drainage to endoscopic retrograde cholangiopancreatography (ERCP) with insertion of metal stents in unresectable malignant distal biliary obstruction (MDBO) and the results were conflicting. The aim of the current study was to compare the outcomes of the procedures in a large-scale study. METHODS: This was a multicenter international randomized controlled study. Consecutive patients admitted for obstructive jaundice due to unresectable MDBO were recruited. Patients were randomly allocated to receive EUS-guided choledocho-duodenostomy (ECDS) or ERCP for drainage. The primary outcome was the 1-year stent patency rate. Other outcomes included technical success, clinical success, adverse events, time to stent dysfunction, reintervention rates, and overall survival. RESULTS: Between January 2017 and February 2021, 155 patients were recruited (ECDS 79, ERCP 76). There were no significant differences in 1-year stent patency rates (ECDS 91.1% vs ERCP 88.1%, P = .52). The ECDS group had significantly higher technical success (ECDS 96.2% vs ERCP 76.3%, P < .001), whereas clinical success was similar (ECDS 93.7% vs ERCP 90.8%, P = .559). The median (interquartile range) procedural time was significantly shorter in the ECDS group (ECDS 10 [5.75-18] vs ERCP 25 [14-40] minutes, P < .001). The rate of 30-day adverse events (P = 1) and 30-day mortality (P = .53) were similar. CONCLUSION: Both procedures could be options for primary biliary drainage in unresectable MDBO. ECDS was associated with higher technical success and shorter procedural time then ERCP. Primary ECDS may be preferred when difficult ERCPs are anticipated. This study was registered to Clinicaltrials.gov NCT03000855.


Assuntos
Colestase , Neoplasias , Humanos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Duodenostomia , Ducto Colédoco , Neoplasias/etiologia , Endossonografia/métodos , Stents/efeitos adversos , Drenagem/efeitos adversos , Drenagem/métodos , Ultrassonografia de Intervenção/métodos
2.
Am J Gastroenterol ; 119(4): 671-681, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37934190

RESUMO

INTRODUCTION: The study aimed to develop international consensus recommendations on the safe use of lumen-apposing metal stents (LAMSs) for on- and off-label indications. METHODS: Based on the available literature, statements were formulated and grouped into the following categories: general safety measures, peripancreatic fluid collections, endoscopic ultrasound (EUS)-biliary drainage, EUS-gallbladder drainage, EUS-gastroenterostomy, and gastric access temporary for endoscopy. The evidence level of each statement was determined using the Grading of Recommendations Assessment, Development, and Evaluation methodology.International LAMS experts were invited to participate in a modified Delphi process. When no 80% consensus was reached, the statement was modified based on expert feedback. Statements were rejected if no consensus was reached after the third Delphi round. RESULTS: Fifty-six (93.3%) of 60 formulated statements were accepted, of which 35 (58.3%) in the first round. Consensus was reached on the optimal learning path, preprocedural imaging, the need for airway protection and essential safety measures during the procedure, such as the use of Doppler, and measurement of the distance between the gastrointestinal lumen and the target structure. Specific consensus recommendations were generated for the different LAMS indications, covering, among others, careful patient selection, the preferred size of the LAMS, the need for antibiotics, the preferred anatomic location of the LAMS, the need for coaxial pigtail placement, and the appropriate management of LAMS-related adverse events. DISCUSSION: Through a modified international Delphi process, we developed general and indication-specific experience- and evidence-based recommendations on the safe use of LAMS.


Assuntos
Endossonografia , Uso Off-Label , Humanos , Consenso , Estudos Retrospectivos , Stents/efeitos adversos , Endoscopia Gastrointestinal , Drenagem/métodos
3.
Br J Surg ; 111(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38198159

RESUMO

BACKGROUND: Differentiation between adenomas and carcinomas of the ampulla of Vater is crucial for therapy and prognosis. This was a systematic review of the literature on the accuracy of diagnostic modalities used to differentiate between benign and malignant ampullary tumours. METHODS: A literature search was conducted in PubMed, Embase, CINAHL, and the Cochrane Library. Studies were included if they reported diagnostic test accuracy information among benign and malignant ampullary tumours, and used pathological diagnosis as the reference standard. Risk of bias was assessed using Quality Assessment on Diagnostic Accuracy Studies (QUADAS) 2 and QUADAS-C. RESULTS: Ten studies comprising 397 patients were included. Frequently studied modalities were (CT; 2 studies), endoscopic ultrasonography (EUS; 3 studies), intraductal ultrasonography (IDUS; 2 studies), and endoscopic forceps biopsy (3 studies). For CT, the reported sensitivity for detecting ampullary carcinoma was 44 and 95%, and the specificity 58 and 60%. For EUS, the sensitivity ranged from 63 to 89% and the specificity between 50 and 100%. A sensitivity of 88 and 100% was reported for IDUS, with a specificity of 75 and 93%. For forceps biopsy, the sensitivity ranged from 20 to 91%, and the specificity from 75 to 86%. The overall risk of bias was scored as moderate to poor. Data were insufficient for meta-analysis. CONCLUSION: To differentiate benign from malignant ampullary tumours, EUS and IDUS seem to be the best diagnostic modalities. Sufficient high-quality evidence, however, is lacking.


Assuntos
Carcinoma , Humanos , Biópsia , Estudos Transversais , Endoscopia , Endossonografia
4.
Curr Opin Gastroenterol ; 40(4): 299-304, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38606810

RESUMO

PURPOSE OF REVIEW: This review aims to discuss recent advancements in the endoscopic management of early esophageal adenocarcinoma (T1 EAC). RECENT FINDINGS: Patients with high-risk EAC (defined by the presence of deep submucosal invasion, and/or lymphovascular invasion, and/or poor differentiation) have a higher risk of lymph node metastases than those with low-risk EAC. However, more recent, endoscopically-focused studies report a lower risk of lymph node metastases and distant metastases for high-risk EAC than previously assumed. Instead of referring all high-risk EAC patients for esophagectomy after a radical endoscopic resection, an alternative approach involving regular upper endoscopy with endoscopic ultrasound may allow for detection of intra-luminal recurrence and lymph node metastases at an early and potentially curable stage. SUMMARY: Endoscopic resection of mucosal and submucosal EAC might prove to be safe and curative for selected cases in the future, when followed by a strict follow-up protocol. Despite the promising results of preliminary studies, there is an ongoing need for personalized strategies and new risk stratification methods to decide on the best management for individual patients with high-risk T1 EAC.


Assuntos
Adenocarcinoma , Neoplasias Esofágicas , Esofagoscopia , Medicina de Precisão , Humanos , Neoplasias Esofágicas/patologia , Neoplasias Esofágicas/terapia , Neoplasias Esofágicas/cirurgia , Adenocarcinoma/patologia , Adenocarcinoma/terapia , Adenocarcinoma/cirurgia , Medicina de Precisão/métodos , Esofagoscopia/métodos , Esofagectomia/métodos , Endossonografia , Metástase Linfática , Estadiamento de Neoplasias , Recidiva Local de Neoplasia/prevenção & controle
5.
Pancreatology ; 24(1): 88-92, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38036413

RESUMO

AIM: High-intensity focused ultrasound (HIFU) is a novel minimally invasive local treatment of solid tumors. Endoscopic ultrasound-guided HIFU (EUS-HIFU) using mechanical effects would have potential benefits, including precise detection of target lesions and enhance drug delivery. The aim of this study is to develop EUS-HIFU device and to prove our concept in porcine model using a locally injected phase change nano droplet (PCND) as the sensitizer. METHOD: A phospholipid PCND contained volatile perfluoro-carbon liquids. The prototype HIFU apparatus comprised a small (20 × 20 mm) transducer with center frequency of 2.1 MHz, attachable to a linear EUS transducer. Under general anesthetic, a single porcine received EUS-guided injection of PCND. The HIFU transducer was placed laparotomically in the stomach, and the liver was ablated through the gastric wall. RESULTS: PCND was injected successfully and a distinct lesion was generated at the HIFU transducer focus only in injected areas that received HIFU exposure at 4.7 kW/cm2 at a duty cycle of 5 % (mean temporal intensity, 0.245 kW/cm2) for 30 s. The generated lesions were mechanically fractionated in macroscopic view. CONCLUSION: The concept of transluminal HIFU ablation using novel EUS-HIFU system was proved in a porcine animal model. This novel treatment system has great potential for future cancer treatment although further investigation in more animals and different organs are warranted.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias , Animais , Suínos , Endossonografia , Fígado , Ultrassonografia de Intervenção
6.
Pancreatology ; 24(4): 649-660, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38714387

RESUMO

BACKGROUND AND AIMS: Solid pancreatic masses are sampled through tissue acquisition by endoscopic ultrasound (EUS). Inadequate samples may significantly delay diagnosis, increasing costs and carrying risks to the patients. AIM: assess the diagnostic adequacy of tissue acquisition using contrast-enhanced harmonic endoscopic ultrasound (CEH-EUS) compared to conventional EUS. METHODS: Five databases (PubMed, Embase, CENTRAL, Scopus and Web of Science) were searched in November 2023. Studies comparing diagnostic adequacy, accuracy and safety using CEH-EUS versus conventional EUS for tissue acquisition of solid pancreatic masses were included. Risk of bias was assessed using the Risk of Bias tool for randomized controlled trials (RoB2) and the Risk Of Bias In Non-Randomized Studies - of Interventions (ROBINS-I) tool for non-randomized studies, level of evidence using the GRADE approach, Odds Ratios (RR) with 95 % Confidence Intervals (CI) calculated and pooled using a random-effects model. I2 quantified heterogeneity. RESULTS: The search identified 3858 records; nine studies (1160 patients) were included. OR for achieving an adequate sample was 1.467 (CI: 0.850-2.533), for randomized trials 0.902 (CI: 0.541-1.505), for non-randomized 2.396 (CI: 0.916-6.264), with significant subgroup difference. OR for diagnostic accuracy was 1.326 (CI: 0.890-1977), for randomized trials 0.997 (CI: 0.593-1.977) and for non-randomized studies 1.928 (CI: 1.096-3.393), significant subgroup difference (p = 0.0467). No differences were observed for technical failures or adverse events. Heterogeneity was low, risk of bias "low" to "some concerns" for most outcomes, mostly moderate for non-randomized studies. CONCLUSION: Non-randomized studies indicated differences in favor of contrast-enhanced EUS, randomized studies showed no difference in diagnostic adequacy, accuracy or sensitivity when using CEH-EUS.


Assuntos
Meios de Contraste , Endossonografia , Humanos , Endossonografia/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Pâncreas/diagnóstico por imagem
7.
Pancreatology ; 24(3): 357-362, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38369393

RESUMO

BACKGROUND AND AIM: Endoscopic ultrasound (EUS)-guided endoscopic necrosectomy is an effective and minimally invasive treatment for walled-off pancreatic necrosis (WON). This study investigated the factors affecting the time interval of EUS-guided WON necrosectomy. METHODS: Patients who received EUS-guided necrosectomy in the Endoscopy Center of the First Affiliated Hospital of Chongqing Medical University in the past 5 years were retrospectively analyzed. Data including general information, etiology, blood biochemical indexes, physical signs, CT severity grade, location, size, solid necrotic ratio, type and number of stents, and immediate necrosectomy were collected to explore the relationships between these factors and the interval of endoscopic necrosectomy. RESULTS: A total of 51 WON patients were included. No significant correlation has been noted between the endoscopic debridement interval and the following indexes, including the patients' general information, the etiology of pancreatitis, blood biochemical indexes (leukocyte count, neutrophil percentage, C-reactive protein), preoperative fever, and WON's location and size, type and number of stents, and whether immediate necrosectomy. However, there were significant differences between the debridement interval and the modified CT Severity Index (MCTSI) (p < 0.001), the solid necrotic ratio of WON (p < 0.001) before the intervention, postoperative fever (p = 0.038), C-reactive protein increasing (p = 0.012) and fever before reintervention (p = 0.024). CONCLUSIONS: The EUS-measured solid necrotic ratio, the MCTSI, postoperative fever, C-reactive protein increase, and fever before reintervention in patients affect the time interval of EUS-guided endoscopic necrosectomy in WON patients. These five indicators may be promisingly effective in predicting and managing endoscopic necrosectomy intervals.


Assuntos
Pancreatite Necrosante Aguda , Humanos , Pancreatite Necrosante Aguda/terapia , Estudos Retrospectivos , Proteína C-Reativa , Endossonografia , Stents , Endoscopia Gastrointestinal , Resultado do Tratamento , Ultrassonografia de Intervenção , Drenagem , Necrose
8.
Pancreatology ; 24(1): 152-159, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37981524

RESUMO

BACKGROUND: Main-duct (MD-) and mixed-type (MT-) IPMNs harbor an increased risk of pancreatic cancer and warrant surgical resection. Preoperative endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) are important in the diagnosis of IPMNs. The aim of this study was to investigate whether endoscopic procedures manipulating the MD impact postoperative adverse events in patients with MD- and MT-IPMNs. METHODS: We performed a retrospective study of 369 patients who underwent resections for MD- or MT-IPMN at two tertiary centers (2000-2019). Multivariable logistic regression analyses were performed for postoperative adverse events to compare the risks between intervention (ERCP, EUS-FNA with branch duct (BD) aspirated, EUS-FNA with MD aspirated from the duct directly or cyst/mass arising from MD) versus no-intervention group. RESULTS: 33.1 % of patients had a preoperative ERCP and 69.4 % had EUS-FNA. Postoperative adverse events included: 30-day readmission (12.7 %), delayed gastric emptying (13.8 %), pancreatic fistula (10.3 %), abdominal abscess (5.7 %), cardiopulmonary adverse events (11.4 %), and mortality (1.4 %). The model was adjusted for potential confounders. There were no significant differences between the ERCP and no-ERCP groups for specific adverse events. Compared to no-EUS-FNA groups, groups of EUS-FNA with BD aspiration and EUS-FNA with MD aspiration from the main pancreatic duct directly or cyst/mass arising from MD did not show a significant increase in specific adverse events. CONCLUSIONS: Postoperative adverse events were not significantly increased among patients who had ERCP or EUS-FNA before surgical resection for MD- or MT-IPMNs. Endoscopic procedures directly sampling the MD can be safely pursued for diagnostic purposes in selected cases.


Assuntos
Cistos , Neoplasias Císticas, Mucinosas e Serosas , Neoplasias Pancreáticas , Humanos , Estudos Retrospectivos , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/diagnóstico , Colangiopancreatografia Retrógrada Endoscópica , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Endossonografia/métodos
9.
Pancreatology ; 24(5): 740-746, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38926041

RESUMO

OBJECTIVES: Pancreatic ductal adenocarcinoma (PDAC) with a diameter ≤10 mm and high-grade pancreatic intraepithelial neoplasia (HG-PanIN) require pre-operative diagnosis. Most cases present only indirect imaging findings without visible tumors on endoscopic ultrasound (EUS). Therefore, EUS-guided fine-needle aspiration/biopsy is not applicable. An alternative diagnostic method is pancreatic juice cytology (PJC) via endoscopic naso-pancreatic drainage (ENPD-PJC), which is not the standard practice. This study aimed to investigate ENPD-PJC for diagnosing suspected PDAC/HG-PanIN cases without visible tumors on EUS. METHODS: Data of patients with suspected PDAC/HG-PanIN without visible tumors who underwent PJC were retrospectively evaluated. One PJC sample was collected during endoscopic retrograde pancreatography (ERP-PJC), and 12 samples were collected during ENPD-PJC, 3-hourly for cytological analysis. ERP-PJC, ERP/ENPD-PJC, and ENPD-PJC positivity indicated cytologically positive samples. Patients with positive/negative PJC with follow-up for <4-years were excluded as undiagnosed cases. A non-malignant diagnosis was based on histopathological absence/stable imaging findings for ≥4-years. The primary endpoint was to demonstrate that ERP/ENPD-PJC has a higher diagnostic ability than ERP-PJC. RESULTS: Twenty-two patients with histopathologically diagnosed PDAC/HG-PanIN and 31 with a non-malignant diagnosis were enrolled. ERP-PJC, ERP/ENPD-PJC, and ENPD-PJC showed sensitivities of 36.4 %, 86.4 %, and 77.3 %, specificities of 93.5 %, 87.1 %, and 93.5 %, and accuracies of 69.8 %, 86.7 %, and 86.7 %, respectively. ERP/ENPD-PJC and ENPD-PJC demonstrated superior sensitivity and accuracy compared to ERP-PJC. A greater occurrence of positive outcomes markedly distinguished true positives from false positives. CONCLUSIONS: ERP/ENPD-PJC and ENPD-PJC had higher diagnostic accuracies for PDAC/HG-PanIN without visible tumors on EUS. ENPD-PJC is recommended for the diagnosis of these lesions.


Assuntos
Carcinoma Ductal Pancreático , Endossonografia , Suco Pancreático , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Suco Pancreático/citologia , Estudos Retrospectivos , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/patologia , Endossonografia/métodos , Idoso de 80 Anos ou mais , Adulto , Carcinoma in Situ/patologia , Carcinoma in Situ/diagnóstico por imagem , Sensibilidade e Especificidade , Citologia
10.
Pancreatology ; 24(2): 255-270, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38182527

RESUMO

This study group aimed to revise the 2017 international consensus guidelines for the management of intraductal papillary mucinous neoplasm (IPMN) of the pancreas, and mainly focused on five topics; the revision of high-risk stigmata (HRS) and worrisome features (WF), surveillance of non-resected IPMN, surveillance after resection of IPMN, revision of pathological aspects, and investigation of molecular markers in cyst fluid. A new development from the prior guidelines is that systematic reviews were performed for each one of these topics, and published separately to provide evidence-based recommendations. One of the highlights of these new "evidence-based guidelines" is to propose a new management algorithm, and one major revision is to include into the assessment of HRS and WF the imaging findings from endoscopic ultrasound (EUS) and the results of cytological analysis from EUS-guided fine needle aspiration technique, when this is performed. Another key element of the current guidelines is to clarify whether lifetime surveillance for small IPMNs is required, and recommends two options, "stop surveillance" or "continue surveillance for possible development of concomitant pancreatic ductal adenocarcinoma", for small unchanged BD-IPMN after 5 years surveillance. Several other points are also discussed, including identifying high-risk features for recurrence in patients who underwent resection of non-invasive IPMN with negative surgical margin, summaries of the recent observations in the pathology of IPMN. In addition, the emerging role of cyst fluid markers that can aid in distinguishing IPMN from other pancreatic cysts and identify those IPMNs that harbor high-grade dysplasia or invasive carcinoma is discussed.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Humanos , Neoplasias Intraductais Pancreáticas/diagnóstico , Neoplasias Intraductais Pancreáticas/cirurgia , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Endossonografia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/cirurgia
11.
Pancreatology ; 24(5): 787-795, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38871559

RESUMO

OBJECTIVES: This study aimed to evaluate the clinical impact of preoperative endoscopic ultrasound-guided tissue acquisition (EUS-TA) on the prognosis and incidence of positive peritoneal lavage cytology (PLC) during laparotomy or staging laparoscopy in patients with resectable (R) or borderline resectable (BR) pancreatic ductal adenocarcinoma (PDAC). METHODS: We retrospectively collected data from patients diagnosed with body and tail PDAC with/without EUS-TA at our hospital from January 2006 to December 2021. RESULTS: To examine the effect of EUS-TA on prognosis, 153 patients (122 in the EUS-TA group, 31 in the non-EUS-TA group) were analyzed. There was no significant difference in overall survival between the EUS-TA and non-EUS-TA groups after PDAC resection (P = 0.777). In univariate and multivariate analysis, preoperative EUS-TA was not identified as an independent factor related to overall survival after pancreatectomy [hazard ratio 0.96, 95 % confidence interval (CI) 0.54-1.70, P = 0.897]. Next, to examine the direct influence of EUS-TA on the results of PLC, 114 patients (83 in the EUS-TA group and 31 in the non-EUS-TA group) were analyzed. Preoperative EUS-TA was not statistically associated with positive PLC (odds ratio 0.73, 95 % CI 0.25-2.20, P = 0.583). After propensity score matching, overall survival and positive PLC were the same in both groups. CONCLUSIONS: EUS-TA had no negative impact on postoperative survival and PLC-positive rates in R/BR PDAC.


Assuntos
Carcinoma Ductal Pancreático , Pancreatectomia , Neoplasias Pancreáticas , Lavagem Peritoneal , Humanos , Masculino , Feminino , Carcinoma Ductal Pancreático/patologia , Carcinoma Ductal Pancreático/cirurgia , Carcinoma Ductal Pancreático/diagnóstico por imagem , Idoso , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos , Prognóstico , Endossonografia , Idoso de 80 Anos ou mais , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Citologia
12.
Gastrointest Endosc ; 99(2): 271-279.e2, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37827432

RESUMO

BACKGROUND AND AIMS: EUS is a high-skill technique that requires numerous procedures to achieve competence. However, training facilities are limited worldwide. Convolutional neural network (CNN) models have been previously implemented for object detection. We developed 2 EUS-based CNN models for normal anatomic structure recognition during real-time linear- and radial-array EUS evaluations. METHODS: The study was performed from February 2020 to June 2022. Consecutive patient videos of linear- and radial-array EUS videos were recorded. Expert endosonographers identified and labeled 20 normal anatomic structures within the videos for training and validation of the CNN models. Initial CNN models (CNNv1) were developed from 45 videos and the improved models (CNNv2) from an additional 102 videos. CNN model performance was compared with that of 2 expert endosonographers. RESULTS: CNNv1 used 45,034 linear-array EUS frames and 21,063 radial-array EUS frames. CNNv2 used 148,980 linear-array EUS frames and 128,871 radial-array EUS frames. Linear-array CNNv1 and radial-array CNNv1 achieved a 75.65% and 71.36% mean average precision (mAP) with a total loss of .19 and .18, respectively. Linear-array CNNv2 obtained an 88.7% mAP with a .06 total loss, whereas radial-array CNNv2 achieved an 83.5% mAP with a .07 total loss. CNNv2 accurately detected all studied normal anatomic structures with a >98% observed agreement during clinical validation. CONCLUSIONS: The proposed CNN models accurately recognize the normal anatomic structures in prerecorded videos and real-time EUS. Prospective trials are needed to evaluate the impact of these models on the learning curves of EUS trainees.


Assuntos
Endossonografia , Redes Neurais de Computação , Humanos , Endossonografia/métodos , Estudos Prospectivos , Gravação de Videoteipe
13.
Gastrointest Endosc ; 99(4): 606-613, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37951278

RESUMO

BACKGROUND AND AIMS: Lumen-apposing metal stents (LAMSs) have revolutionized the treatment of various gastroenterologic conditions that previously required surgery. The use of LAMSs for the management of small-bowel obstruction (SBO) involves EUS-guided coloenterostomy (EUS-CE) between the colon and a dilated loop of the small intestine proximal to the point of obstruction. This procedure is potentially beneficial for patients with malignant SBO who are poor surgical candidates. METHODS: A retrospective cohort study was conducted at 2 tertiary care hospitals. Patients who underwent EUS-CE for SBO were identified, and data regarding patient demographics, indication for the procedure, location of the obstruction, procedural details, and adverse events were collected. The primary outcome was technical success of the procedure. Secondary outcomes were clinical success, resolution of symptoms, ability to tolerate enteral nutrition, and adverse events. RESULTS: Twenty-six patients who underwent the EUS-CE procedure were included. Technical success was achieved in all 26 patients, clinical success (resolution of obstructive symptoms) was achieved in 92.3% of patients (24/26), and the ability to resume enteral nutrition in 84.6% (22/26). Adverse events occurred in 4 patients (15.4%) and included bleeding (1/26), diarrhea (2/26), and postprocedure sepsis (1/26). Patients were followed for a mean of 54.8 days (range, 2-190). CONCLUSIONS: This study highlights that EUS-CE with LAMSs can be performed with high technical and clinical success for the management of SBO, particularly in patients with malignant obstructions who are not suitable candidates for surgical interventions. Further research with larger sample sizes will be essential to substantiate its efficacy and safety.


Assuntos
Endossonografia , Stents , Humanos , Estudos Retrospectivos , Intestino Delgado , Colo , Drenagem/métodos , Ultrassonografia de Intervenção , Resultado do Tratamento
14.
Gastrointest Endosc ; 99(6): 1032-1034, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38280533

RESUMO

BACKGROUND AND AIMS: Balloons are used in EUS to improve visualization. However, data on the safety of latex balloons in patients with latex allergies are limited, and nonlatex alternatives can be costly. We investigated the safety of latex balloon use during EUS. METHODS: A retrospective review was conducted at a tertiary center between 2019 and 2022. Patients with reported latex allergies who underwent linear EUS were included. Baseline demographics, EUS characteristics, and adverse events were collected. The primary outcome was the rate of adverse events. RESULTS: Eighty-seven procedures were performed on 57 unique patients (mean age, 65.3 ± 14.5 years). Latex balloons were used in 59 procedures (67.8%), with only 8 procedures (13.6%) using prophylactic medications. No adverse events occurred during or after procedures, regardless of medication use or history of anaphylaxis. CONCLUSIONS: The use of EUS latex balloons in patients with a latex allergy was associated with no adverse events.


Assuntos
Endossonografia , Hipersensibilidade ao Látex , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Látex/efeitos adversos
15.
Gastrointest Endosc ; 99(4): 537-547.e4, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37956896

RESUMO

BACKGROUND AND AIMS: The clinical management of small gastric submucosal tumors (SMTs) (<2 cm) faces a non-negligible challenge because of the lack of guideline consensus and effective diagnostic tools. This article develops an automatically optimized radiomics modeling system (AORMS) based on EUS images to diagnose and evaluate SMTs. METHODS: A total of 205 patients with EUS images of small gastric SMTs (<2 cm) were retrospectively enrolled in the development phase of AORMS for the diagnosis and the risk stratification of GI stromal tumor (GIST). A total of 178 patients with images from different centers were prospectively enrolled in the independent testing phase. The performance of AORMS was compared to that of endoscopists in the development set and evaluated in the independent testing set. RESULTS: AORMS demonstrated an area under the curve (AUC) of 0.762 for the diagnosis of GIST and 0.734 for the risk stratification of GIST, respectively. In the independent testing set, AORMS achieved an AUC of 0.770 and 0.750 for the diagnosis and risk stratification of small GISTs, respectively. In comparison, the AUCs of 5 experienced endoscopists ranged from 0.501 to 0.608 for diagnosing GIST and from 0.562 to 0.748 for risk stratification. AORMS outperformed experienced endoscopists by more than 20% in diagnosing GIST. CONCLUSIONS: AORMS implements automatic parameter selection, which enhances its robustness and clinical applicability. It has demonstrated good performance in the diagnosis and risk stratification of GISTs, which could aid endoscopists in the diagnosis of small gastric SMTs (<2 cm).


Assuntos
Tumores do Estroma Gastrointestinal , Neoplasias Gástricas , Humanos , Tumores do Estroma Gastrointestinal/patologia , Radiômica , Estudos Retrospectivos , Neoplasias Gástricas/patologia , Endossonografia/métodos
16.
Gastrointest Endosc ; 100(1): 132-135, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38382885

RESUMO

BACKGROUND AND AIMS: With the global obesity pandemic, clinical scenarios requiring urgent ERCP in patients with gastric bypass surgery are on the rise, and single-session EUS-directed transgastric ERCP (SS-EDGE) can effectively address these technical challenges. The aim of this study was to evaluate and describe the safe and effective use of a through-the-scope endoscopic suturing system for anchoring the lumen-apposing metal stents (LAMSs) during SS-EDGE. METHODS: Six patients with Roux-en-Y gastric bypass (RYGB) underwent SS-EDGE at our center. A through-the-scope endoscopic suturing system was used for anchoring the LAMSs during SS-EDGE. RESULTS: Clinical and technical success was achieved in all 6 patients without any adverse events related to the procedure. No stent migration, pneumoperitoneum, or GI perforation was noted. At the 4-week follow-up, no stent migration was noted, and the through-the-scope suturing system remained anchored. LAMSs along with tacks were removed, and gastric fistulae were successfully closed endoscopically in all patients to prevent weight gain. CONCLUSIONS: Use of through-the-scope endoscopic suturing can be a safe, reliable, and potentially cost-effective novel technique for LAMS fixation to successfully perform SS-EDGE in RYGB patients.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Endossonografia , Derivação Gástrica , Stents , Técnicas de Sutura , Humanos , Projetos Piloto , Feminino , Derivação Gástrica/métodos , Técnicas de Sutura/instrumentação , Colangiopancreatografia Retrógrada Endoscópica/métodos , Pessoa de Meia-Idade , Masculino , Endossonografia/métodos , Adulto , Migração de Corpo Estranho/prevenção & controle , Migração de Corpo Estranho/cirurgia , Fístula Gástrica/cirurgia , Fístula Gástrica/etiologia
17.
Gastrointest Endosc ; 99(3): 444-448.e1, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37871846

RESUMO

BACKGROUND AND AIMS: EUS-guided gallbladder drainage using lumen-apposing metal stents (EUS-GBD-LAMSs) and percutaneous cholecystostomy for gallbladder drainage (PTGBD) are the alternative treatment modalities in high-risk surgical patients with acute cholecystitis (AC). The aim of this study was to compare the safety of these procedures for AC in surgically suboptimal candidates. METHODS: Six studies compared the 2 groups' early, delayed, and overall adverse events; they also compared length of hospital stay, re-interventions, and re-admissions rate. A random effect model calculated odds ratios (ORs) with a 95% confidence interval (CI). RESULTS: The 2 groups had similar early adverse events; however, EUS-GBD-LAMS was associated with a lower rate of delayed (OR, .21; 95% CI, .07-.61; P ≤ .01) and overall (OR, .43; 95% CI, .30-.61; P ≤ .01) adverse events. Patients with EUS-GBD-LAMSs had a shorter hospital stay than PTGBD. CONCLUSIONS: EUS-GBD-LAMS is a safer option than PTGBD and is associated with a shorter hospital stay in nonsurgical candidates with AC.


Assuntos
Colecistite Aguda , Colecistostomia , Humanos , Vesícula Biliar/cirurgia , Colecistostomia/métodos , Endossonografia/métodos , Drenagem/métodos , Colecistite Aguda/cirurgia , Colecistite Aguda/etiologia , Stents , Resultado do Tratamento
18.
Gastrointest Endosc ; 99(1): 108-115.e1, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37739237

RESUMO

BACKGROUND AND AIMS: Ultrathin EGD (UT-EGD) is an ideal tool for unsedated upper GI examination and pediatric gastroenterology but is rarely competent for EUS miniprobe (EUS-MP). We developed a UT-EGD US method (UT-EUS) and verified its clinical application value through animal experiments. METHODS: Five Bama miniature pigs were selected. Using an acoustic medium, we performed US on the duodenum, stomach, and esophagus, respectively, with conventional 20-MHz EUS miniprobe (EUS-MP-20), 20-MHz UT-EUS (UT-EUS-20), and 30-MHz UT-EUS (UT-EUS-30). The times to acquire 5 consecutive stable US images, number of identifiable wall layers, and quality and penetration depth of the images were recorded. RESULTS: No significant differences were found in the time required to obtain images between EUS-MP-20 and UT-EUS-20 at each site (P > .05). UT-EUS-30 showed more wall levels than UT-EUS-20 (P < .05). No significant differences were noted between EUS-MP-20 and UT-EUS-20 in imaging quality and penetration depth (P > .05). CONCLUSIONS: The UT-EUS is easy to use with a satisfactory image quality and has potential clinical application value.


Assuntos
Endoscopia do Sistema Digestório , Ultrassom , Humanos , Criança , Suínos , Animais , Endoscopia do Sistema Digestório/métodos , Endoscópios , Endossonografia/métodos , Esôfago/diagnóstico por imagem
19.
Gastrointest Endosc ; 99(1): 31-37, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37532106

RESUMO

BACKGROUND AND AIMS: Despite the significant morbidity associated with gastric variceal bleeding, there is a paucity of high-quality data regarding optimal management. EUS-guided coil injection therapy (EUS-COIL) has recently emerged as a promising endoscopic modality for the treatment of gastric varices (GV), particularly compared with traditional direct endoscopic glue injection. Although there are data on the feasibility and safety of EUS-COIL in the management of GV, these have been limited to select centers with particular expertise. The aim of this study was to report the first U.S. multicenter experience of EUS-COIL for the management of GV. METHODS: This retrospective analysis included patients with bleeding GV or GV at risk of bleeding who underwent EUS-COIL at 10 U.S. tertiary care centers between 2018 and 2022. Baseline patient and procedure-related information was obtained. EUS-COIL entailed the injection of .018 inch or .035 inch hemostatic coils using a 22-gauge or 19-gauge FNA needle. Primary outcomes were technical success (defined as successful deployment of coil into varix under EUS guidance with diminution of Doppler flow), clinical success (defined as cessation of bleeding if present and/or absence of bleeding at 30 days' postintervention), and intraprocedural and postprocedural adverse events. RESULTS: A total of 106 patients were included (mean age 60.4 ± 12.8 years; 41.5% female). The most common etiology of GV was cirrhosis (71.7%), with alcohol being the most common cause (43.4%). Overall, 71.7% presented with acute GV bleeding requiring intensive care unit stay and/or blood transfusion. The most common GV encountered were isolated GV type 1 (60.4%). A mean of 3.8 ± 3 coils were injected with a total mean length of 44.7 ± 46.1 cm. Adjunctive glue or absorbable gelatin sponge was injected in 82% of patients. Technical success and clinical success were 100% and 88.7%, respectively. Intraprocedural adverse events (pulmonary embolism and GV bleeding from FNA needle access) occurred in 2 patients (1.8%), and postprocedural adverse events occurred in 5 (4.7%), of which 3 were mild. Recurrent bleeding was observed in 15 patients (14.1%) at a mean of 32 days. Eighty percent of patients with recurrent bleeding were successfully re-treated with repeat EUS-COIL. No significant differences were observed in outcomes between high-volume (>15 cases) and low-volume (<7 cases) centers. CONCLUSIONS: This U.S. multicenter experience on EUS-COIL for GV confirms high technical and clinical success with low adverse events. No significant differences were seen between high- and low-volume centers. Repeat EUS-COIL seems to be an effective rescue option for patients with recurrent bleeding GV. Further prospective studies should compare this modality versus other interventions commonly used for GV.


Assuntos
Varizes Esofágicas e Gástricas , Hemostase Endoscópica , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Hemorragia Gastrointestinal/terapia , Hemorragia Gastrointestinal/tratamento farmacológico , Varizes Esofágicas e Gástricas/terapia , Varizes Esofágicas e Gástricas/complicações , Hemostase Endoscópica/efeitos adversos , Cianoacrilatos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Endossonografia/efeitos adversos
20.
Gastrointest Endosc ; 100(1): 66-75, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38382887

RESUMO

BACKGROUND AND AIMS: EUS-guided hepaticogastrostomy (EUS-HGS) is a rescue procedure when ERCP fails. Peritonitis and recurrent biliary obstruction (RBO) are adverse events (AEs) associated with EUS-HGS. Antegrade stent placement across a malignant distal biliary obstruction (DBO) followed by EUS-HGS (EUS-HGAS) creates 2 biliary drainage routes, potentially reducing peritonitis and prolonging time to RBO (TRBO). We compared the outcomes of the 2 techniques. METHODS: Data of consecutive patients with malignant DBO who underwent attempted EUS-HGS or EUS-HGAS across 5 institutions from January 2014 to December 2020 were retrospectively analyzed. A matched cohort of patients was obtained using 1-to-1 propensity score matching. The primary outcome was TRBO, and secondary outcomes were AEs except for RBO and overall survival. RESULTS: Among 360 patients, 283 (176 and 107 in the HGS and HGAS groups, respectively) were eligible. The matched cohorts included 81 patients in each group. AEs developed in 10 (12.3%) and 15 (18.5%) patients (P = .38) in the HGS and HGAS groups, respectively. RBO occurred in 18 and 2 patients in the HGS and HGAS groups, respectively (P < .001). TRBO was significantly longer in the HGAS group (median, 194 days vs 716 days; hazard ratio, .050; 95% confidence interval, .0066-.37; P < .01). However, no significant differences occurred in overall survival between the groups (median, 97 days vs 112 days; hazard ratio, .97; 95% confidence interval, .66-1.4; P = .88). CONCLUSIONS: EUS-HGAS extended TRBO compared with EUS-HGS, whereas AEs, except for RBO and overall survival, did not differ. The longer TRBO of EUS-HGAS could benefit patients with longer life expectancy.


Assuntos
Colestase , Endossonografia , Pontuação de Propensão , Stents , Humanos , Masculino , Feminino , Colestase/cirurgia , Colestase/etiologia , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Estudos de Casos e Controles , Gastrostomia/métodos , Drenagem/métodos , Neoplasias dos Ductos Biliares/complicações , Neoplasias dos Ductos Biliares/cirurgia , Ultrassonografia de Intervenção , Idoso de 80 Anos ou mais
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa