Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.401
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 121(40): e2402983121, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39312669

RESUMO

Human inborn errors of the type I IFN response pathway and auto-Abs neutralizing IFN-α, -ß, and/or -ω can underlie severe viral illnesses. We report a simple assay for the detection of both types of condition. We stimulate whole blood from healthy individuals and patients with either inborn errors of type I IFN immunity or auto-Abs against type I IFNs with glycosylated human IFN-α2, -ß, or -ω. As controls, we add a monoclonal antibody (mAb) blocking the type I IFN receptors and stimulated blood with IFN-γ (type II IFN). Of the molecules we test, IP-10 (encoded by the interferon-stimulated gene (ISG) CXCL10) is the molecule most strongly induced by type I and type II IFNs in the whole blood of healthy donors in an ELISA-like assay. In patients with inherited IFNAR1, IFNAR2, TYK2, or IRF9 deficiency, IP-10 is induced only by IFN-γ, whereas, in those with auto-Abs neutralizing specific type I IFNs, IP-10 is also induced by the type I IFNs not neutralized by the auto-Abs. The measurement of type I and type II IFN-dependent IP-10 induction therefore constitutes a simple procedure for detecting rare inborn errors of the type I IFN response pathway and more common auto-Abs neutralizing type I IFNs.


Assuntos
Quimiocina CXCL10 , Interferon Tipo I , Humanos , Interferon Tipo I/imunologia , Quimiocina CXCL10/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Receptor de Interferon alfa e beta/genética , Interferon gama/sangue , Interferon gama/imunologia
2.
J Immunol ; 210(7): 1004-1010, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36752720

RESUMO

Recombinant Abs are gaining increasing importance for the treatment of certain cancers or immunological or neurologic disorders. The ELISA is one of the most used analytical tools for detecting and quantifying Abs of interest. However, the performance of ELISAs often varies because of nonstandard experimental procedures as well as inadequate data analysis. In our study, we standardized a procedure and statistical analysis for a highly sensitive ELISA of a mouse Ab in mouse (C57BL/6J) CNS tissue. The following steps are of crucial importance: 1) calculation of the limit of detection based on control tissue lysate samples in the same testing buffer as the testing samples; 2) calculation of the limit of quantification as measured with acceptable accuracy and precision; and 3) a five-parameter logistic regression model to interpolate the symmetric and asymmetric standard curves. We also show that three amplification Abs can significantly increase the sensitivity of the ELISA compared with a two amplification Ab setup. This standardized procedure may be a valuable tool to increase the sensitivity, reproducibility, and precision of ELISA studies in basic science and translational research.


Assuntos
Anticorpos , Sistema Nervoso Central , Animais , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Camundongos Endogâmicos C57BL , Ensaio de Imunoadsorção Enzimática/métodos
3.
Am J Respir Crit Care Med ; 210(7): 908-918, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38385694

RESUMO

Rationale: Sarcoidosis is a systemic granulomatous disorder associated with hypergammaglobulinemia and the presence of autoantibodies. The specific antigens initiating granulomatous inflammation in sarcoidosis are unknown, and there is no specific test available to diagnose sarcoidosis. To discover novel sarcoidosis antigens, we developed a high-throughput T7 phage display library derived from the sarcoidosis cDNA and identified numerous clones differentiating sarcoidosis from other respiratory diseases. After clone sequencing and a homology search, we identified two epitopes (cofilin µ and chain A) that specifically bind to serum IgGs of patients with sarcoidosis. Objectives: To develop and validate an epitope-specific IgG-based immunoassay specific for sarcoidosis. Methods: We chemically synthesized both immunoepitopes (cofilin µ and chain A) and generated rabbit polyclonal antibodies against both neoantigens. After extensive standardization, we developed a direct peptide ELISA and measured epitope-specific IgG in the sera of 386 subjects, including healthy control subjects (n = 100), three sarcoidosis cohorts (n = 186), pulmonary tuberculosis (n = 70), and lung cancer (n = 30). Measurements and Main Results: To develop a model to classify sarcoidosis distinctly from other groups, data were analyzed using fivefold cross-validation when adjusting for confounders. The cofilin µ IgG model yielded a mean sensitivity, specificity, and positive and negative predictive value of 0.97, 0.9, 0.9, and 0.96, respectively. Those same measures for chain A IgG antibody were 0.9, 0.83, 0.84, and 0.9, respectively. Combining both biomarkers improved the area under the curve, sensitivity, specificity, and positive and negative predictive value. Conclusions: These results provide a novel immunoassay for sarcoidosis. The discovery of two neoantigens facilitates the development of biospecific drug discovery and the sarcoidosis-specific model.


Assuntos
Epitopos , Sarcoidose , Humanos , Sarcoidose/imunologia , Sarcoidose/diagnóstico , Sarcoidose/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Epitopos/imunologia , Adulto , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Idoso , Ensaio de Imunoadsorção Enzimática/métodos , Imunoensaio/métodos , Animais , Sensibilidade e Especificidade , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/diagnóstico , Coelhos
4.
J Lipid Res ; 65(4): 100532, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38608546

RESUMO

To support in vivo and in vitro studies of intravascular triglyceride metabolism in mice, we created rat monoclonal antibodies (mAbs) against mouse LPL. Two mAbs, mAbs 23A1 and 31A5, were used to develop a sandwich ELISA for mouse LPL. The detection of mouse LPL by the ELISA was linear in concentrations ranging from 0.31 ng/ml to 20 ng/ml. The sensitivity of the ELISA made it possible to quantify LPL in serum and in both pre-heparin and post-heparin plasma samples (including in grossly lipemic samples). LPL mass and activity levels in the post-heparin plasma were lower in Gpihbp1-/- mice than in wild-type mice. In both groups of mice, LPL mass and activity levels were positively correlated. Our mAb-based sandwich ELISA for mouse LPL will be useful for any investigator who uses mouse models to study LPL-mediated intravascular lipolysis.


Assuntos
Anticorpos Monoclonais , Ensaio de Imunoadsorção Enzimática , Lipase Lipoproteica , Animais , Lipase Lipoproteica/metabolismo , Lipase Lipoproteica/sangue , Camundongos , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos Monoclonais/imunologia , Ratos , Receptores de Lipoproteínas/metabolismo , Receptores de Lipoproteínas/genética , Camundongos Knockout
5.
Cancer Sci ; 115(5): 1602-1610, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38480462

RESUMO

Anti-programmed death-ligand 1 (PD-L1) Ab-based therapies have demonstrated potential for treating metastatic urothelial cancer with high PD-L1 expression. Urinary exosomes are promising biomarkers for liquid biopsy, but urine's high variability requires normalization for accurate analysis. This study proposes using the PD-L1/Alix ratio to normalize exosomal PD-L1 signal intensity with Alix, an internal exosomal protein less susceptible to heterogeneity concerns than surface protein markers. Extracellular vesicles were isolated using ExoDisc and characterized using various methods, including ExoView to analyze tetraspanins, PD-L1, and Alix on individual exosomes. On-disc ELISA was used to evaluate PD-L1 and Alix-normalized PD-L1 in 15 urothelial cancer patients during the initial treatment cycle with Tecentriq. Results showed that Alix signal range was relatively uniform, whereas tetraspanin marker intensity varied for individual exosome particles. On-disc ELISA was more reliable for detecting exosomal PD-L1 expression than standard plate ELISA-based measurement. Using exosomal Alix expression for normalization is a more reliable approach than conventional methods for monitoring patient status. Overall, the study provides a practical and reliable method for detecting exosomal PD-L1 in urine samples from patients with urothelial cancer.


Assuntos
Antígeno B7-H1 , Biomarcadores Tumorais , Exossomos , Humanos , Exossomos/metabolismo , Antígeno B7-H1/urina , Biomarcadores Tumorais/urina , Proteínas de Ciclo Celular/urina , Ensaio de Imunoadsorção Enzimática/métodos , Masculino , Neoplasias da Bexiga Urinária/urina , Neoplasias da Bexiga Urinária/patologia , Feminino , Idoso , Pessoa de Meia-Idade , Neoplasias Urológicas/urina , Neoplasias Urológicas/patologia , Biópsia Líquida/métodos
6.
Anal Chem ; 96(8): 3489-3497, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-38349730

RESUMO

Selection and characterization of antibodies are critically important in establishing robust immunoassays to support the development efforts of vaccines. Plate-based ELISA can be time- and resource-intensive to select initial antibody clones or characterize downstream resupply lots while providing limited information regarding the binding characteristics of the antibodies beyond concentration-response curves. This work applied the microfluidic Gyrolab to holistically evaluate immunoassay reagents through analyses of concentration-response curves as well as antibody-antigen interactions visualized in column images and affinity estimates. We exploited the automation capability of the Gyrolab to reduce the resources (time, reagents, and scientists) required for screening and evaluating antibody reagents. Using a flexible semi-universal assay format, we compared antibody clones for selection and resupply lots of sera and monoclonal antibodies in a simple "plug-and-play" manner without antibody modifications. We found that the performance of antibodies in the Gyrolab correlated well with the trends observed in traditional ELISAs, while the Gyrolab provided additional advantages over plate-based assays such as column images of antibody binding and affinity measurements.


Assuntos
Anticorpos Monoclonais , Microfluídica , Indicadores e Reagentes , Imunoensaio/métodos , Ensaio de Imunoadsorção Enzimática/métodos
7.
Anal Chem ; 96(23): 9676-9683, 2024 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-38813952

RESUMO

Enzyme-linked immunosorbent assays (ELISAs) are widely used in biology and clinical diagnosis. Relying on antigen-antibody interaction through diffusion, the standard ELISA protocol can be time-consuming, preventing its use in rapid diagnostics. We present a time-saving and more sensitive ELISA without changing the standard setup and protocol, using surface acoustic waves (SAWs) to enhance performance. Each step of the assay, from the initial antibody binding onto the walls of the well plate to the target analyte molecules' binding for detection─except, notably, for the blocking step─is improved principally via acoustic streaming-driven advection. Using SAWs, the time required for one step of an example ELISA is reduced from 60 to 15 min to achieve the same binding amount. By extending the duration of SAW exposure to 20 min, the sensitivity can be significantly improved over the 60 min, 35 °C ELISA without SAWs. It is also possible to confer beneficial improvements to bead-based ELISA by combining it with SAWs to further reduce the time required for binding to 2 min. By significantly increasing the speed of ELISA, its utility may be improved for a wide range of point-of-care diagnostics applications.


Assuntos
Ensaio de Imunoadsorção Enzimática , Som , Ensaio de Imunoadsorção Enzimática/métodos , Propriedades de Superfície , Humanos , Anticorpos/imunologia , Acústica
8.
Anal Chem ; 96(1): 488-495, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38156369

RESUMO

The growth of therapeutic monoclonal antibodies (mAbs) continues to accelerate due to their success as treatments for many diseases. As new therapeutics are developed, it is increasingly important to have robust bioanalytical methods to measure the pharmacokinetics (PK) of circulating therapeutic mAbs in serum. Ligand-binding assays such as enzyme-linked immunosorbent assays (ELISAs) with anti-idiotypic antibodies (anti-IDs) targeting the variable regions of the therapeutic antibody are sensitive and specific bioanalytical methods to measure levels of therapeutic antibodies in a biological matrix. However, soluble circulating drug mAb targets can interfere with the anti-IDs binding to the therapeutic mAb, thereby resulting in an underestimation of total drug concentration. Therefore, in addition to a high binding affinity for the mAb, the selection of anti-IDs and the assay format that are not impacted by soluble antigens and have low matrix interference is essential for developing a robust PK assay. Standardized automated approaches to screen and select optimal reagents and assay formats are critical to increase efficiency, quality, and PK assay robustness. However, there does not exist an integrated screening and analysis platform to develop robust PK assays across multiple formats. We have developed an automated workflow and scoring platform with multiple bioanalytical assay parameters that allow for ranking of candidate anti-IDs. A primary automated indirect electrochemiluminescence (ECL) was utilized to shortlist the anti-IDs that were selected for labeling and screening in pairs. A secondary screen using an ECL sandwich assay with labeled-anti-ID pairings was used to test multiple PK assay formats to identify the best anti-ID pairing/PK assay format. We developed an automated assay using fixed plate maps combined with a human-guided graphical user interface-based scoring system and compared it to a data-dependent scoring system using Gaussian mixture models for automated scoring and selection. Our approach allowed for screening of anti-IDs and identification of the most robust PK assay format with significantly reduced time and resources compared with traditional approaches. We believe that such standardized, automated, and integrated platforms that accelerate the development of PK assays will become increasingly important for supporting future human clinical trials.


Assuntos
Anticorpos Monoclonais , Antígenos , Humanos , Fluxo de Trabalho , Ligantes , Anticorpos Monoclonais/análise , Ensaio de Imunoadsorção Enzimática/métodos
9.
Anal Chem ; 96(3): 980-984, 2024 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-38194441

RESUMO

The 2023 Nobel Prize in Chemistry honors the groundbreaking contributions of Alexei Ekimov, Louis Brus, and Moungi Bawendi to the field of quantum dots (QDs). In this spirit, we developed a direct competitive QD fluorescence immunoassay (dc-QD-FLISA) to detect aristolochic acid type I (AAI), a potent carcinogen found in herbal remedies. Unexpectedly, the dc-QD-FLISA exhibited lower sensitivity than that of an indirect competitive enzyme-linked immunosorbent assay (ic-ELISA), contrary to our initial expectations. This discrepancy in the sensitivity prompted a comprehensive analysis of the entire experimental process. We propose that steric hindrance between QDs and antigen-binding sites on antibodies may significantly diminish the binding efficiency, reducing sensitivity within the dc-QD-FLISA method. Furthermore, issues such as buffer conditions, antibody handling, and separation methods are also contributing factors. We recommend site-directed QD modification and stringent consideration of the experimental conditions. This study not only provides insights into QD-based immunoassays but also highlights the need for future advancements in immunoassay technology in terms of augmenting sensitivity and specificity, potentially revolutionizing disease diagnosis, biomarker discovery, and biomedical research.


Assuntos
Pontos Quânticos , Pontos Quânticos/química , Imunoensaio/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Anticorpos/química , Sensibilidade e Especificidade
10.
Anal Chem ; 96(41): 16134-16144, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39360754

RESUMO

Detection and quantification of viral particles (VPs) facilitate both diagnostics of pathogenic viruses and quality control testing of virus-based products. However, existing technologies fail to afford concurrent ultrasensitive detection and large-scale absolute quantification of VPs. Here, we propose a digital Microgel-in-Droplet enzyme-linked immunosorbent assay (ELISA) system that enables the processing and monitoring of millions of ELISA reactions at the single-VP level by incorporating droplet microfluidics with sandwich ELISA. Upon validating the microfluidic workflow and optimizing ELISA parameters, we demonstrate ultrasensitive VP detection at a limit of detection of 56 PFU/test. Leveraging a fluorescence-based screening platform, we further realize high-throughput digital counting of VPs with a linear detection range of 500-64 000 PFU/test. The precision is comparable to that of the gold standard, the plaque assay, across a wide range of virus concentrations. We anticipate that our system will provide a novel paradigm for the absolute enumeration of various types of viral particles.


Assuntos
Ensaio de Imunoadsorção Enzimática , Ensaio de Imunoadsorção Enzimática/métodos , Microgéis/química , Limite de Detecção , Técnicas Analíticas Microfluídicas , Orthomyxoviridae/isolamento & purificação , Humanos
11.
Anal Chem ; 96(24): 10064-10073, 2024 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-38842443

RESUMO

The global spread of monkeypox has become a worldwide public healthcare issue. Therefore, there is an urgent need for accurate and sensitive detection methods to effectively control its spreading. Herein, we screened by phage display two peptides M4 (sequence: DPCGERICSIAL) and M6 (sequence: SCSSFLCSLKVG) with good affinity and specificity to monkeypox virus (MPXV) B21R protein. To simulate the state of the peptide in the phage and to avoid spatial obstacles of the peptide, GGGSK was added at the C terminus of M4 and named as M4a. Molecular docking shows that peptide M4a and peptide M6 are bound to different epitopes of B21R by hydrogen bonds and salt-bridge interactions, respectively. Then, peptide M4a was selected as the capture probe, phage M6 as the detection probe, and carbonized polymer dots (CPDs) as the fluorescent probe, and a colorimetric and fluorescent double-signal capture peptide/antigen/signal peptide-displayed phage sandwich ELISA triggered by horseradish peroxidase (HRP) through a simple internal filtration effect (IFE) was constructed. HRP catalyzes H2O2 to oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to generate blue oxidized TMB, which can further quench the fluorescence of CPDs through IFE, enabling to detect MPXV B21R in colorimetric and fluorescent modes. The proposed simple immunoassay platform shows good sensitivity and reliability in MPXV B21R detection. The limit of detection for colorimetric and fluorescent modes was 27.8 and 9.14 pg/mL MPXV B21R, respectively. Thus, the established double-peptide sandwich-based dual-signal immunoassay provides guidance for the development of reliable and sensitive antigen detection capable of mutual confirmation, which also has great potential for exploring various analytical strategies for other respiratory virus surveillance.


Assuntos
Ensaio de Imunoadsorção Enzimática , Peptídeos , Ensaio de Imunoadsorção Enzimática/métodos , Peptídeos/química , Antígenos Virais/imunologia , Antígenos Virais/análise , Antígenos Virais/química , Simulação de Acoplamento Molecular , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Limite de Detecção , Corantes Fluorescentes/química , Biblioteca de Peptídeos , Benzidinas/química , Colorimetria/métodos
12.
Anal Chem ; 96(28): 11205-11215, 2024 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-38967035

RESUMO

Lipid nanoparticles (LNPs) are emerging as one of the most promising drug delivery systems. The long-circulating effect of intact LNPs (i-LNPs) is the key to efficacy and toxicity in vivo. However, the significant challenge is specific and sensitive detection of i-LNPs. Herein, a dual-recognition fluorescence enzyme-linked immunosorbent assay (DR-FELISA) was developed to directly isolate and detect i-LNPs by combining dual-recognition separation with a one-step signal amplification strategy. The microplates captured and enriched i-LNPs through antibody-antigen reaction. Dual-chol probes were spontaneously introduced into the lipid bilayer of captured i-LNPs, converting the detection of i-LNPs into the detection of double-cholesterol probes. Finally, the end of the dual-chol probes initiated the localized scaffolding autocatalytic DNA circuits (SADC) system for further signal amplification. The SADC system provides a sensitive and efficient amplifier through localized network structures and self-assembled triggers. Simultaneous recognition of i-LNPs surface PEG-lipid and lipid bilayer structures significantly eliminates interference from biological samples. i-LNPs were detected with high selectivity, ranging from 0.2 to 1.25 mg/mL with a limit of detection of 0.1 mg/mL. Moreover, this method allows the isolation and quantitative analysis of different formulations of i-LNPs in serum samples with a satisfactory recovery rate ranging from 94.8 to 116.3%. Thus, the DR-FELISA method provides an advanced platform for the exclusive and sensitive detection of i-LNPs, providing new insights for the study of the quality and intracorporal process of complex formulations.


Assuntos
Ensaio de Imunoadsorção Enzimática , Ensaio de Imunoadsorção Enzimática/métodos , DNA Catalítico/química , DNA Catalítico/metabolismo , Nanopartículas/química , Técnicas de Amplificação de Ácido Nucleico/métodos , Humanos , Corantes Fluorescentes/química , Estudos de Viabilidade
13.
J Clin Microbiol ; 62(10): e0059324, 2024 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-39194193

RESUMO

The Advisory Committee on Immunization Practices (ACIP) recommended that dengue pre-vaccination screening tests for Dengvaxia administration have at least 98% specificity and 75% sensitivity. This study evaluates the performance of commercial anti-DENV IgG tests to identify tests that could be used for pre-vaccination screening. First, for seven tests, we evaluated sensitivity and specificity in early convalescent dengue virus (DENV) infection, using 44 samples collected 7-30 days after symptom onset and confirmed by RT-PCR. Next, for the five best-performing tests and two additional tests (with and without an external test reader) that became available later, we evaluated performance to detect past dengue infection among a panel of 44 specimens collected in 2018-2019 from healthy 9- to 16-year-old children from Puerto Rico. Finally, a full-scale evaluation was done with the four best-performing tests using 400 specimens from the same population. We used virus focus reduction neutralization test and an in-house DENV IgG ELISA as reference standards. Of seven tests, five showed ≥75% sensitivity in detecting anti-DENV IgG in early convalescent specimens with low cross-reactivity to the Zika virus. For the detection of previous DENV infections, the tests with the highest performance were the Euroimmun NS1 IgG ELISA (sensitivity 84.5%, specificity 97.1%) and CTK Dengue IgG rapid test R0065C with the test reader (sensitivity 76.2% specificity 98.1%). There are IgG tests available that can be used to accurately classify individuals with previous DENV infection as eligible for dengue vaccination to support safe vaccine implementation. IMPORTANCE: The Advisory Committee on Immunization Practices (ACIP) has set forth recommendations that dengue pre-vaccination screening tests must exhibit at least 98% specificity and 75% sensitivity. Our research rigorously assesses the performance of various commercial tests against these benchmarks using well-characterized specimens from Puerto Rico. The findings from our study are particularly relevant given FDA approval and ACIP recommendation of Sanofi Pasteur's Dengvaxia vaccine, highlighting the need for accurate pre-vaccination screening tools.


Assuntos
Anticorpos Antivirais , Vacinas contra Dengue , Vírus da Dengue , Dengue , Imunoglobulina G , Sensibilidade e Especificidade , Humanos , Dengue/diagnóstico , Dengue/prevenção & controle , Dengue/imunologia , Imunoglobulina G/sangue , Vírus da Dengue/imunologia , Criança , Anticorpos Antivirais/sangue , Adolescente , Vacinas contra Dengue/imunologia , Porto Rico , Ensaio de Imunoadsorção Enzimática/métodos , Masculino , Feminino , Vacinação , Testes de Neutralização/métodos
14.
Clin Chem ; 70(10): 1268-1278, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39206639

RESUMO

BACKGROUND: New immunoglobulin free light chain (FLC) assays are available. Despite analytical differences, it seems possible to use free light chain ratios (FLCr) generated by different assays and apply similar cut-points for the diagnosis of multiple myeloma. It is still unknown if we can use different assays for risk stratification of patients with monoclonal gammopathy of undetermined significance (MGUS). METHODS: Patients diagnosed with MGUS (N = 923) had FLC tested using a nephelometric FreeLite (Binding Site) assay on BNII instruments (Siemens) and a Sebia FLC assay (Sebia) on a DS2 ELISA analyzer (Dynex). Patients were followed up for progression to any plasma cell dyscrasia (PCD) for several decades. The Mayo MGUS risk stratification model for progression was assessed with both assays (M-spike >1.5 g/dL; non-IgG isotype and abnormal FLCr), using package insert reference intervals (RI) and a new metric called principal component 2 (PC2). RESULTS: There were 94 events of progression to PCD in the cohort during a median of 38 years of follow-up. Freelite and Sebia FLC showed similar hazard ratios in the risk models for elevated FLCr. An alternative clinical decision point lower than the package insert RI was evaluated for the Sebia assay, which improved risk stratification for patients with a low FLCr. The PC2 metric showed similar performance to the FLCr in models, without superior benefit. CONCLUSIONS: The Sebia ELISA-based FLC assay can be employed in an MGUS risk stratification model with similar performance to the original 2005 risk stratification model using the FreeLite assay.


Assuntos
Progressão da Doença , Cadeias Leves de Imunoglobulina , Gamopatia Monoclonal de Significância Indeterminada , Humanos , Cadeias Leves de Imunoglobulina/sangue , Gamopatia Monoclonal de Significância Indeterminada/diagnóstico , Gamopatia Monoclonal de Significância Indeterminada/sangue , Fatores de Risco , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ensaio de Imunoadsorção Enzimática/métodos
15.
J Med Virol ; 96(8): e29843, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39092814

RESUMO

Tick-borne encephalitis (TBE) virus is the most prevalent tick-transmitted orthoflavivirus in Europe. Due to the nonspecific nature of its symptoms, TBE is primarily diagnosed by ELISA-based detection of specific antibodies in the patient serum. However, cross-reactivity between orthoflaviviruses complicates the diagnosis. Specificity issues may be mitigated by serum neutralization assays (SNT), although the handling of clinically relevant orthoflaviviruses requires biosafety level (BSL) 3 conditions and they have highly divergent viral kinetics and cell tropisms. In the present study, we established a reporter virus particle (RVP)-based SNT in which the infectivity is measured by luminescence and that can be performed under BSL-2 conditions. The RVP-based SNT for TBEV exhibited a highly significant correlation with the traditional virus-based SNT (R2 = 0.8637, p < 0.0001). The RVP-based assay demonstrated a sensitivity of 92.3% (95% CI: 79.7%-97.4%) and specificity of 100% (95% CI: 81.6%-100%). We also tested the cross-reactivity of serum samples in RVP-based assays against other orthoflaviviruses (yellow fever virus, dengue virus type 2, Zika virus, West Nile virus and Japanese encephalitis virus). Interestingly, all serum samples which had tested TBEV-positive by ELISA but negative by RVP-based SNT were reactive for antibodies against other orthoflaviviruses. Thus, the RVP-based seroneutralization assay provides an added value in clinical diagnostics as well as in epidemiological studies.


Assuntos
Anticorpos Antivirais , Reações Cruzadas , Vírus da Encefalite Transmitidos por Carrapatos , Encefalite Transmitida por Carrapatos , Ensaio de Imunoadsorção Enzimática , Testes de Neutralização , Sensibilidade e Especificidade , Vírus da Encefalite Transmitidos por Carrapatos/imunologia , Humanos , Anticorpos Antivirais/sangue , Testes de Neutralização/métodos , Encefalite Transmitida por Carrapatos/diagnóstico , Encefalite Transmitida por Carrapatos/virologia , Ensaio de Imunoadsorção Enzimática/métodos , Vírion/imunologia , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Animais
16.
Cytokine ; 174: 156449, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38141459

RESUMO

Research on C-X-C motif chemokine ligand 10 (CXCL10) has been widely reported for humans and select animal species, yet immune reagents are limited for pig chemokines. Our goal is to provide veterinary immunologists and the biomedical community with new commercial immune reagents and standardized assays. Recombinant porcine CXCL10 (rPoCXCL10) protein was produced by yeast expression and used to generate a panel of α CXCL10 monoclonal antibodies (mAbs). All mAbs were assessed for cross-inhibition and reactivity to orthologous yeast expressed CXCL10 proteins. Characterization of a panel of nine α PoCXCL10 mAbs identified six distinct antigenic determinants. A sensitive quantitative sandwich ELISA was developed with anti-PoCXCL10-1.6 and -1.9 mAb; reactivity was verified with both rPoCXCL10 and native PoCXCL10, detected in supernatants of peripheral blood mononuclear cells stimulated with rPoIFNγ or PMA/Ionomycin. Immunostaining of in vitro rPoIFNγ stimulated pig spleen and blood cells verified CXCL10 + cells as CD3-CD4-CD172+, with occasional CD3-CD4 + CD172 + subsets. Comparison studies determined that α PoCXCL10-1.4 mAb was the ideal mAb clone for intracellular staining, whereas with α PoCXCL10-1.1 and -1.2 mAbs were best for immunohistochemistry analyses. These techniques and tools will be useful for evaluating swine immune development, responses to infectious diseases and vaccines, as well as for improving utility of pigs as an important biomedical model.


Assuntos
Anticorpos Monoclonais , Leucócitos Mononucleares , Humanos , Animais , Suínos , Leucócitos Mononucleares/metabolismo , Saccharomyces cerevisiae , Imuno-Histoquímica , Ensaio de Imunoadsorção Enzimática/métodos , Quimiocina CXCL10/metabolismo
17.
Cytokine ; 182: 156719, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39084066

RESUMO

OBJECTIVE: Recently, the Pediatric Rheumatology International Trials Organization (PRINTO) has proposed revisions to the current International League of Associations for Rheumatology (ILAR) criteria for systemic juvenile idiopathic arthritis (s-JIA). Interleukin (IL)-18 overproduction plays a significant role in the pathogenesis of s-JIA. This study aimed to evaluate the performance of the PRINTO criteria compared with the ILAR criteria and determine whether serum IL-18 levels improve their diagnostic performances. METHODS: Overall, 90 patients with s-JIA and 27 patients with other febrile disease controls presenting with a prolonged fever of > 14 days and arthritis and/or erythematous rash were enrolled. The ILAR and PRINTO classification criteria were applied to all patients and examined with expert diagnoses. Enzyme-linked immunosorbent assay was used for measuring serum IL-18 levels. RESULTS: The PRINTO criteria had higher sensitivity but lower specificity than the ILAR criteria (sensitivity: PRINTO 0.856, ILAR 0.533; specificity: PRINTO 0.259, ILAR 0.851). With the addition of serum IL-18 levels ≥ 4,800 pg/mL, the sensitivity of the ILAR criteria and specificity of the PRINTO criteria were improved to 1.000 and 1.000, respectively. PRINTO plus serum IL-18 levels ≥ 4,800 pg/mL showed the highest value in Youden's index (sensitivity - [1 - specificity]). CONCLUSION: Serum IL-18 levels could improve the diagnostic performance of the PRINTO and ILAR criteria for s-JIA. The PRINTO criteria plus serum IL-18 levels ≥ 4,800 pg/mL could be the best diagnostic performance for s-JIA.


Assuntos
Artrite Juvenil , Interleucina-18 , Humanos , Artrite Juvenil/sangue , Artrite Juvenil/diagnóstico , Interleucina-18/sangue , Masculino , Feminino , Criança , Pré-Escolar , Sensibilidade e Especificidade , Adolescente , Lactente , Ensaio de Imunoadsorção Enzimática/métodos , Reumatologia/métodos
18.
Microb Pathog ; 190: 106615, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38521472

RESUMO

In this study, we successfully developed a nanobody-based double antibody sandwich ELISA kit for the detection of clinical serum C-reactive protein (CRP) by using two novel CRP specific nanobodies. The developed method exhibited a linear detection range of approximately 6-200 ng/mL, with a detection limit of 1 ng/mL. Furthermore, the method demonstrated excellent specificity, as there was no cross-reactivity with interfering substances such as total bilirubin and hemoglobin and so on. To assess reproducibility, independent measurements of the samples were conducted under experimental conditions, resulting in intra- and inter-batch coefficients of variation below 10% and a recovery rate of 93%-102%. These results indicate robust reproducibility of the method. To evaluate the performance of the developed kit, we collected 90 clinical samples for correlation analysis with commercial kits. The results showed a high correlation coefficient value (R2) of 0.98, indicating accurate concordance between the developed and commercial kits. In conclusion, our study successfully developed a nanobody-based double antibody sandwich ELISA kit to detect clinical serum CRP. The utilization of nanobodies represents a significant advancement in the field of CRP immunoassay development. The developed kit demonstrates excellent performance characteristics and holds promise for clinical applications.


Assuntos
Proteína C-Reativa , Ensaio de Imunoadsorção Enzimática , Anticorpos de Domínio Único , Ensaio de Imunoadsorção Enzimática/métodos , Proteína C-Reativa/análise , Humanos , Anticorpos de Domínio Único/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Limite de Detecção
19.
Anal Biochem ; 694: 115623, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39059567

RESUMO

CM310 is a recombinant humanized monoclonal antibody targeting Interleukin (IL)-4 receptor alpha (IL-4Rα). IL-4Rα blockade prevents IL-4 and IL-13 from binding to their receptor, thereby inhibiting downstream signaling pathways that drive Type 2 helper T-cell (Th2) inflammation. CM310 holds potential for treating Th2-related inflammatory diseases, such as asthma, atopic dermatitis and chronic sinusitis with nasal polyposis. In this study, a direct enzyme-linked immunosorbent assay (ELISA) was developed to measure the concentrations of CM310 in rat serum. Seven calibration standards (ranging from 25 to 1600 ng/mL) and three quality controls (70, 500 and 1250 ng/mL) were defined. The limit of detection (LOD), lower limit of quantification (LLOQ) and upper limit of quantification (ULOQ) were 13, 25 and 1600 ng/mL, respectively. The method exhibited excellent precision and accuracy and successfully applied to in vitro serum stability and pharmacokinetic (PK) studies. In conclusion, we have developed and validated a highly sensitive and selective method for measuring CM310 in Sprague-Dawley rats. The development and validation ELISA method met the acceptable criteria, which suggested that these can be applied to quantify CM310, as well as in PK studies.


Assuntos
Ensaio de Imunoadsorção Enzimática , Ratos Sprague-Dawley , Animais , Ensaio de Imunoadsorção Enzimática/métodos , Ratos , Proteínas Recombinantes , Anticorpos Monoclonais Humanizados/farmacocinética , Masculino , Limite de Detecção , Humanos , Subunidade alfa de Receptor de Interleucina-4/antagonistas & inibidores , Anticorpos Monoclonais/farmacocinética , Anticorpos Monoclonais/sangue
20.
Anal Biochem ; 695: 115656, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39216635

RESUMO

Trichomoniasis is the most prevalent curable, non-viral sexually transmitted infection (STI), with an estimated 156 million new infections in 2020. It can potentially result in adverse birth outcomes as well as infertility in men, whilst it also increases the risk of acquiring HIV and contracting other vaginal infections. It is mostly prevalent among women in low-income countries and especially in Africa and the Americas. This STI is caused by Trichomonas vaginalis (TV) and a robust, cost-effective, sensitive, specific and rapid diagnostic test is urgently required. We report the screening of 6 full-length and 4 truncated aptamers previously selected in our group for use in a microplate-based sandwich assay. The combination of dual aptamers comprising a short 14-mer truncated capture aptamer (termed A1_14mer) and a full-length non-truncated reporter aptamer (A6) was elucidated to be the optimum pair for a sensitive sandwich enzyme-linked aptamer assay (ELAA) for the detection of TV achieving a detection limit of 3.02 × 104 TV cells/mL. The results obtained with the A1_14mer-A6 ELAA correlate excellently with wet-mount microscopy for the detection of TV in clinical specimens, cervicovaginal lavages and vaginal swabs, highlighting the potential clinical application of this assay for cost-effective population screening and subsequent prevention of the onset of complications associated with undiagnosed and untreated TV.


Assuntos
Aptâmeros de Nucleotídeos , Trichomonas vaginalis , Trichomonas vaginalis/isolamento & purificação , Aptâmeros de Nucleotídeos/química , Humanos , Feminino , Vaginite por Trichomonas/diagnóstico , Tricomoníase/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa