Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.497
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nature ; 630(8015): 84-90, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38840015

RESUMO

Direct and precise monitoring of intracranial physiology holds immense importance in delineating injuries, prognostication and averting disease1. Wired clinical instruments that use percutaneous leads are accurate but are susceptible to infection, patient mobility constraints and potential surgical complications during removal2. Wireless implantable devices provide greater operational freedom but include issues such as limited detection range, poor degradation and difficulty in size reduction in the human body3. Here we present an injectable, bioresorbable and wireless metastructured hydrogel (metagel) sensor for ultrasonic monitoring of intracranial signals. The metagel sensors are cubes 2 × 2 × 2 mm3 in size that encompass both biodegradable and stimulus-responsive hydrogels and periodically aligned air columns with a specific acoustic reflection spectrum. Implanted into intracranial space with a puncture needle, the metagel deforms in response to physiological environmental changes, causing peak frequency shifts of reflected ultrasound waves that can be wirelessly measured by an external ultrasound probe. The metagel sensor can independently detect intracranial pressure, temperature, pH and flow rate, realize a detection depth of 10 cm and almost fully degrade within 18 weeks. Animal experiments on rats and pigs indicate promising multiparametric sensing performances on a par with conventional non-resorbable wired clinical benchmarks.


Assuntos
Implantes Absorvíveis , Encéfalo , Hidrogéis , Monitorização Fisiológica , Ondas Ultrassônicas , Tecnologia sem Fio , Animais , Masculino , Ratos , Encéfalo/fisiologia , Hidrogéis/química , Concentração de Íons de Hidrogênio , Injeções/instrumentação , Pressão Intracraniana , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Ratos Sprague-Dawley , Porco Miniatura , Temperatura , Fatores de Tempo , Tecnologia sem Fio/instrumentação
2.
N Engl J Med ; 390(1): 9-19, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37888915

RESUMO

BACKGROUND: Among patients with chronic limb-threatening ischemia (CLTI) and infrapopliteal artery disease, angioplasty has been associated with frequent reintervention and adverse limb outcomes from restenosis. The effect of the use of drug-eluting resorbable scaffolds on these outcomes remains unknown. METHODS: In this multicenter, randomized, controlled trial, 261 patients with CLTI and infrapopliteal artery disease were randomly assigned in a 2:1 ratio to receive treatment with an everolimus-eluting resorbable scaffold or angioplasty. The primary efficacy end point was freedom from the following events at 1 year: amputation above the ankle of the target limb, occlusion of the target vessel, clinically driven revascularization of the target lesion, and binary restenosis of the target lesion. The primary safety end point was freedom from major adverse limb events at 6 months and from perioperative death. RESULTS: The primary efficacy end point was observed (i.e., no events occurred) in 135 of 173 patients in the scaffold group and 48 of 88 patients in the angioplasty group (Kaplan-Meier estimate, 74% vs. 44%; absolute difference, 30 percentage points; 95% confidence interval [CI], 15 to 46; one-sided P<0.001 for superiority). The primary safety end point was observed in 165 of 170 patients in the scaffold group and 90 of 90 patients in the angioplasty group (absolute difference, -3 percentage points; 95% CI, -6 to 0; one-sided P<0.001 for noninferiority). Serious adverse events related to the index procedure occurred in 2% of the patients in the scaffold group and 3% of those in the angioplasty group. CONCLUSIONS: Among patients with CLTI due to infrapopliteal artery disease, the use of an everolimus-eluting resorbable scaffold was superior to angioplasty with respect to the primary efficacy end point. (Funded by Abbott; LIFE-BTK ClinicalTrials.gov number, NCT04227899.).


Assuntos
Angioplastia , Implante de Prótese Vascular , Isquemia Crônica Crítica de Membro , Stents Farmacológicos , Doença Arterial Periférica , Artéria Poplítea , Humanos , Implantes Absorvíveis , Angioplastia/efeitos adversos , Angioplastia/métodos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Implante de Prótese Vascular/métodos , Doença Crônica , Isquemia Crônica Crítica de Membro/etiologia , Isquemia Crônica Crítica de Membro/cirurgia , Everolimo/administração & dosagem , Everolimo/efeitos adversos , Everolimo/uso terapêutico , Imunossupressores/administração & dosagem , Imunossupressores/efeitos adversos , Imunossupressores/uso terapêutico , Isquemia/tratamento farmacológico , Isquemia/etiologia , Isquemia/cirurgia , Doença Arterial Periférica/complicações , Doença Arterial Periférica/tratamento farmacológico , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Alicerces Teciduais , Resultado do Tratamento
3.
Proc Natl Acad Sci U S A ; 120(11): e2217734120, 2023 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-36888661

RESUMO

Degradable polymer matrices and porous scaffolds provide powerful mechanisms for passive, sustained release of drugs relevant to the treatment of a broad range of diseases and conditions. Growing interest is in active control of pharmacokinetics tailored to the needs of the patient via programmable engineering platforms that include power sources, delivery mechanisms, communication hardware, and associated electronics, most typically in forms that require surgical extraction after a period of use. Here we report a light-controlled, self-powered technology that bypasses key disadvantages of these systems, in an overall design that is bioresorbable. Programmability relies on the use of an external light source to illuminate an implanted, wavelength-sensitive phototransistor to trigger a short circuit in an electrochemical cell structure that includes a metal gate valve as its anode. Consequent electrochemical corrosion eliminates the gate, thereby opening an underlying reservoir to release a dose of drugs by passive diffusion into surrounding tissue. A wavelength-division multiplexing strategy allows release to be programmed from any one or any arbitrary combination of a collection of reservoirs built into an integrated device. Studies of various bioresorbable electrode materials define the key considerations and guide optimized choices in designs. In vivo demonstrations of programmed release of lidocaine adjacent the sciatic nerves in rat models illustrate the functionality in the context of pain management, an essential aspect of patient care that could benefit from the results presented here.


Assuntos
Implantes Absorvíveis , Sistemas de Liberação de Medicamentos , Ratos , Animais , Eletrônica , Polímeros
4.
Circulation ; 148(13): 989-999, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37624364

RESUMO

BACKGROUND: Limited information is available on the comparative efficacy and safety of different stent platforms in patients at high bleeding risk undergoing an abbreviated dual antiplatelet therapy duration after percutaneous coronary intervention (PCI). The aim of this study was to compare the safety and effectiveness of the biodegradable-polymer sirolimus-eluting stent with the durable-polymer zotarolimus-eluting stent in patients at high bleeding risk receiving 1 month of dual antiplatelet therapy after PCI. METHODS: The Bioflow-DAPT Study is an international, randomized, open-label trial conducted at 52 interventional cardiology hospitals in 18 countries from February 24, 2020, through September 20, 2021. Patients with a clinical indication to PCI because of acute or chronic coronary syndrome who fulfilled 1 or more criteria for high bleeding risk were eligible for enrollment. Patients were randomized to receive either biodegradable-polymer sirolimus-eluting stents or durable-polymer, slow-release zotarolimus-eluting stents after successful lesion preparation, followed by 1 month of dual antiplatelet therapy and thereafter single antiplatelet therapy. The primary outcome was the composite of death from cardiac causes, myocardial infarction, or stent thrombosis at 1 year, and was powered for noninferiority, with an absolute margin of 4.1% at 1-sided 5% alpha. RESULTS: A total of 1948 patients at high bleeding risk were randomly assigned (1:1) to receive biodegradable-polymer sirolimus-eluting stents (969 patients) or durable-polymer zotarolimus-eluting stents (979 patients). At 1 year, the primary outcome was observed in 33 of 969 patients (3.6%) in the biodegradable-polymer sirolimus-eluting stent group and in 32 of 979 patients (3.4%) in the durable-polymer zotarolimus-eluting stent group (risk difference, 0.2 percentage points; upper boundary of the 1-sided 95% CI, 1.8; upper boundary of the 1-sided 97.5% CI, 2.1; P<0.0001 for noninferiority for both tests). CONCLUSIONS: Among patients at high risk for bleeding who received 1 month of dual antiplatelet therapy after PCI, the use of biodegradable-polymer sirolimus-eluting stents was noninferior to the use of durable-polymer zotarolimus-eluting stents with regard to the composite of death from cardiac causes, myocardial infarction, or stent thrombosis. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04137510.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento , Implantes Absorvíveis , Sirolimo/efeitos adversos , Infarto do Miocárdio/tratamento farmacológico , Stents/efeitos adversos , Trombose/etiologia
5.
Lancet ; 402(10416): 1979-1990, 2023 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-37898137

RESUMO

BACKGROUND: Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS: BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS: Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION: In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING: Biotronik.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Sirolimo/uso terapêutico , Everolimo/uso terapêutico , Seguimentos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Polímeros , Teorema de Bayes , Método Simples-Cego , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/métodos
6.
Small ; 20(28): e2307742, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38326101

RESUMO

Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.


Assuntos
Metais , Corrosão , Metais/química , Microtomografia por Raio-X , Próteses e Implantes , Eletroquímica , Implantes Absorvíveis , Técnicas Eletroquímicas/métodos
7.
Am Heart J ; 277: 1-10, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39098754

RESUMO

BACKGROUND: Modern drug-eluting stents have seen significant improvements, yet still create a rigid cage within the coronary artery. There is a 2% to 4% annual incidence of target lesion failure (TLF) beyond 1 year, and half of the patients experience angina after 5 years. The DynamX bioadaptor is a sirolimus-eluting, thin (71 µm) cobalt-chromium platform with helical strands that unlock and separate after in vivo degradation of the bioresorbable polymer coating. This allows the vessel to return to normal physiological function and motion, along with compensatory adaptive remodeling, which may reduce the need for reintervention and alleviate angina following percutaneous coronary intervention (PCI). METHODS: The INFINITY-SWEDEHEART trial is a single-blind, registry-based randomized clinical trial (R-RCT) to evaluate the safety and effectiveness of the DynamX bioadaptor compared to the Resolute Onyx stent in the treatment of patients with ischemic heart disease with de novo native coronary artery lesions. The R-RCT framework allows for recruitment, randomization, and pragmatic data collection of baseline demographics, medications, and clinical outcomes using existing national clinical registries integrated with the trial database. The primary objective is to demonstrate noninferiority in terms of freedom from TLF (cardiovascular death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) at 1 year. Powered secondary endpoints will be tested sequentially for superiority from 6 months to the end of follow-up (5 years) for the following: 1) TLF in all subjects, 2) target vessel failure in all subjects, and 3) TLF in subjects with acute coronary syndrome (ACS). Subsequent superiority testing will be performed at a time determined depending on the number of events, ensuring sufficient statistical power. Change in angina-related symptoms, function and quality of life will be assessed using the Seattle Angina Questionnaire-short version. Predefined sub-groups will be analyzed. In total, 2400 patients have been randomized at 20 sites in Sweden. Available baseline characteristic reveal relatively old age (68 years) and a large proportion of ACS patients including 25% STEMI and 37% NSTEMI patients. SUMMARY: The INFINITY-SWEDEHEART study is designed to evaluate the long-term safety and efficacy of the DynamX bioadaptor compared to the Resolute Onyx stent in a general PCI patient population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Sistema de Registros , Sirolimo , Humanos , Sirolimo/farmacologia , Sirolimo/análogos & derivados , Método Simples-Cego , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Doença da Artéria Coronariana/terapia , Resultado do Tratamento , Masculino , Feminino , Implantes Absorvíveis
8.
Am Heart J ; 275: 53-61, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38838969

RESUMO

BACKGROUND: The previous first-in-human study established the preliminary safety and effectiveness of the novel thin-strut iron bioresorbable scaffold (IBS). The current study aims to directly compare the imaging and physiological efficacy, and clinical outcomes of IBS with contemporary metallic drug-eluting stents (DES). METHODS: A total of 518 patients were randomly allocated to treatment with IBS (257 patients) or metallic DES (261 patients) from 36 centers in China. The study is powered to test noninferiority of the IBS compared with the metallic everolimus-eluting stent in terms of the primary endpoint of in-segment late lumen loss at 2 years, and major secondary endpoints including 2-year quantitative flow ratio and cross-sectional mean flow area measured by optical coherence tomography (OCT) (limited to the OCT subgroup, 25 patients in each group). CONCLUSION: This will be the first powered randomized trial investigating the safety and efficacy of the novel thin-strut IBS compared to a contemporary metallic DES. The findings will provide valuable evidence for future research of this kind and the application of metallic bioresorbable scaffolds.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana , Stents Farmacológicos , Everolimo , Sirolimo , Tomografia de Coerência Óptica , Humanos , Everolimo/administração & dosagem , Everolimo/farmacologia , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia , Sirolimo/análogos & derivados , Sirolimo/administração & dosagem , Sirolimo/farmacologia , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Desenho de Prótese , Ferro , Alicerces Teciduais , Intervenção Coronária Percutânea/métodos , Imunossupressores/administração & dosagem , Imunossupressores/farmacologia , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38091338

RESUMO

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Assuntos
Síndrome Coronariana Aguda , Ácidos Alcanossulfônicos , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Trombose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Fatores de Risco , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Implantes Absorvíveis , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos , Trombose Coronária/etiologia , Stents/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos
10.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658140

RESUMO

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Assuntos
Fraturas Ósseas , Granuloma de Corpo Estranho , Infecções dos Tecidos Moles , Humanos , Masculino , Feminino , Criança , Magnésio , Implantes Absorvíveis , Granuloma de Corpo Estranho/etiologia , Infecções dos Tecidos Moles/etiologia , Fraturas Ósseas/etiologia , Ligas , Fixação Interna de Fraturas/métodos , Parafusos Ósseos/efeitos adversos
11.
Circ J ; 88(6): 863-872, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38479861

RESUMO

BACKGROUND: The 1-year clinical outcomes of the Absorb GT1 Japan post-market surveillance (PMS) suggested that an appropriate intracoronary imaging-guided bioresorbable vascular scaffold (BVS) implantation technique may reduce the risk of target lesion failure (TLF) and scaffold thrombosis (ST) associated with the Absorb GT1 BVS. The long-term outcomes through 5 years are now available. METHODS AND RESULTS: This study enrolled 135 consecutive patients (n=139 lesions) with ischemic heart disease in whom percutaneous coronary intervention (PCI) with the Absorb GT1 BVS was attempted. Adequate lesion preparation, imaging-guided appropriate sizing, and high-pressure post-dilatation using a non-compliant balloon were strongly encouraged. All patients had at least 1 Absorb GT1 successfully implanted at the index procedure. Intracoronary imaging was performed in all patients (optical coherence tomography: 127/139 [91.4%] lesions) and adherence to the implantation technique recommendations was excellent: predilatation, 100% (139/139) lesions; post-dilatation, 98.6% (137/139) lesions; mean (±SD) post-dilatation pressure, 18.8±3.5 atm. At 5 years, the follow-up rate was 87.4% (118/135). No definite/probable ST was reported through 5 years. The cumulative TLF rate was 5.1% (6/118), including 2 cardiac deaths, 1 target vessel-attributable myocardial infarction, and 3 ischemia-driven target lesion revascularizations. CONCLUSIONS: Appropriate intracoronary imaging-guided BVS implantation, including the proactive use of pre- and post-balloon dilatation during implantation may be beneficial, reducing the risk of TLF and ST through 5 years.


Assuntos
Implantes Absorvíveis , Vigilância de Produtos Comercializados , Humanos , Japão , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Intervenção Coronária Percutânea/efeitos adversos , Tomografia de Coerência Óptica , Seguimentos , Alicerces Teciduais , Isquemia Miocárdica , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem
12.
Circ J ; 88(6): 876-884, 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38569870

RESUMO

BACKGROUND: The safety and feasibility of using 1-month dual antiplatelet therapy (DAPT) followed by P2Y12inhibitor monotherapy for patients after percutaneous coronary intervention (PCI) with thin-strut biodegradable polymer drug-eluting stents (BP-DES) in daily clinical practice remain uncertain. METHODS AND RESULTS: The REIWA region-wide registry is a prospective study conducted in 1 PCI center and 9 local hospitals in northern Japan. A total of 1,202 patients who successfully underwent final PCI using BP-DES (Synergy: n=400; Ultimaster: n=401; Orsiro: n=401), were enrolled in the registry, and received 1-month DAPT followed by P2Y12inhibitor (prasugrel 3.75 mg/day or clopidogrel 75 mg/day) monotherapy. The primary endpoint was a composite of cardiovascular and bleeding events at 12 months, including cardiovascular death, myocardial infarction (MI), definite stent thrombosis (ST), ischemic or hemorrhagic stroke, and Thrombolysis in Myocardial Infarction (TIMI) major or minor bleeding. Based on the results of a previous study, we set the performance goal at 5.0%. Over the 1-year follow-up, the primary endpoint occurred in 3.08% of patients, which was lower than the predefined performance goal (Pnon-inferiority<0.0001). Notably, definite ST occurred in only 1 patient (0.08%) within 1 year (at 258 days). No differences were observed in the primary endpoint between stent types. CONCLUSIONS: The REIWA region-wide registry suggests that 1-month DAPT followed by P2Y12inhibitor monotherapy is safe and feasible for Japanese patients with BP-DES.


Assuntos
Implantes Absorvíveis , Clopidogrel , Stents Farmacológicos , Terapia Antiplaquetária Dupla , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Antagonistas do Receptor Purinérgico P2Y , Sistema de Registros , Humanos , Masculino , Idoso , Feminino , Intervenção Coronária Percutânea/efeitos adversos , Pessoa de Meia-Idade , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Clopidogrel/uso terapêutico , Clopidogrel/efeitos adversos , Clopidogrel/administração & dosagem , Estudos Prospectivos , Japão , Terapia Antiplaquetária Dupla/métodos , Hemorragia/induzido quimicamente , Cloridrato de Prasugrel/administração & dosagem , Cloridrato de Prasugrel/uso terapêutico , Cloridrato de Prasugrel/efeitos adversos , Polímeros , Resultado do Tratamento
13.
Colorectal Dis ; 26(4): 760-765, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38321510

RESUMO

Carbon ion radiotherapy (CIRT) has received attention for the treatment of locally recurrent rectal cancer. When the surrounding primary organs are close to the irradiation site, a spacer is required to ensure safe irradiation. This work describes a novel technique using a bioabsorbable polyglycolic acid spacer placed laparoscopically and presents a technical report with five case studies. The short-term surgical outcomes were as follows: mean operating time 235 min with blood loss of 38 mL. CIRT was planned, and the patients underwent irradiation within 2 months of surgery. No pelvic infections occurred, and all procedures were performed safely. Herein, were present a technical report with reference to a video of the surgical procedure.


Assuntos
Implantes Absorvíveis , Laparoscopia , Recidiva Local de Neoplasia , Ácido Poliglicólico , Neoplasias Retais , Humanos , Neoplasias Retais/cirurgia , Neoplasias Retais/radioterapia , Laparoscopia/métodos , Recidiva Local de Neoplasia/cirurgia , Pessoa de Meia-Idade , Feminino , Masculino , Idoso , Resultado do Tratamento , Duração da Cirurgia
14.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443753

RESUMO

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Assuntos
Implantes Absorvíveis , Anastomose Cirúrgica , Colectomia , Neoplasias do Colo , Íleo , Procedimentos Cirúrgicos Robóticos , Grampeadores Cirúrgicos , Colectomia/métodos , Colectomia/instrumentação , Humanos , Anastomose Cirúrgica/métodos , Anastomose Cirúrgica/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias do Colo/cirurgia , Íleo/cirurgia , Procedimentos Cirúrgicos sem Sutura/métodos , Procedimentos Cirúrgicos sem Sutura/instrumentação , Duração da Cirurgia , Colo/cirurgia , Resultado do Tratamento , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/instrumentação , Adulto , Tempo de Internação
15.
Surg Endosc ; 38(6): 3433-3440, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38710888

RESUMO

INTRODUCTION: Fixation of mesh during minimally invasive inguinal hernia repair is thought to contribute to chronic post-herniorrhaphy groin pain (CGP). In contrast to permanent tacks, absorbable tacks are hypothesized to minimize the likelihood of CGP. This study aimed to compare the rates of CGP after laparoscopic inguinal hernia repair between absorbable versus permanent fixation at maximum follow-up. METHODS: This is a post hoc analysis of a randomized controlled trial in patients undergoing laparoscopic inguinal hernia repair (NCT03835351). All patients were contacted at maximum follow-up after surgery to administer EuraHS quality of life (QoL) surveys. The pain and restriction of activity subdomains of the survey were utilized. The primary outcome was rate of CGP, as defined by a EuraHS QoL pain domain score ≥ 4 measured at ≥ 1 year postoperatively. The secondary outcomes were pain and restriction of activity domain scores and hernia recurrence at maximum follow-up. RESULTS: A total of 338 patients were contacted at a mean follow-up of 28 ± 11 months. 181 patients received permanent tacks and 157 patients received absorbable tacks during their repair. At maximum follow-up, the rates of CGP (27 [15%] vs 28 [18%], P = 0.47), average pain scores (1.78 ± 4.38 vs 2.32 ± 5.40, P = 0.22), restriction of activity scores (1.39 ± 4.32 vs 2.48 ± 7.45, P = 0.18), and the number of patients who reported an inguinal bulge (18 [9.9%] vs 15 [9.5%], P = 0.9) were similar between patients with permanent versus absorbable tacks. On multivariable analysis, there was no significant difference in the odds of CGP between the two groups (OR 1.23, 95% CI [0.60, 2.50]). CONCLUSION: Mesh fixation with permanent tacks does not appear to increase the risk of CGP after laparoscopic inguinal hernia repair when compared to fixation with absorbable tacks. Prospective trials are needed to further evaluate this relationship.


Assuntos
Implantes Absorvíveis , Dor Crônica , Virilha , Hérnia Inguinal , Herniorrafia , Laparoscopia , Dor Pós-Operatória , Telas Cirúrgicas , Humanos , Hérnia Inguinal/cirurgia , Laparoscopia/métodos , Laparoscopia/efeitos adversos , Herniorrafia/métodos , Herniorrafia/efeitos adversos , Masculino , Dor Pós-Operatória/etiologia , Pessoa de Meia-Idade , Feminino , Virilha/cirurgia , Dor Crônica/etiologia , Idoso , Qualidade de Vida , Seguimentos , Adulto
16.
J Clin Periodontol ; 51(9): 1134-1146, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38828551

RESUMO

AIM: To evaluate the radiographic outcomes of lateral sinus floor elevation with simultaneous implant placement at sites without sinus membrane perforation (SMP) and sites with SMP managed with a resorbable membrane. MATERIALS AND METHODS: One hundred and thirty-nine patients and 170 implants (56 perforation, 114 non-perforation) were included. Cone-beam computed tomography (CBCT) images were taken before surgery (T0), immediately after surgery (T1) and 6 months after surgery (T2). Post-operative augmentation parameters, including endo-sinus bone gain (ESBG) along the implant axis, mean new bone height (NBH) surrounding the implant and augmentation volume (AV), were measured at T1 and T2. RESULTS: At T1, there were no significant differences in ESBG, NBH and AV between the two groups. At T2, although ESBG did not significantly differ between the two groups, NBH (8.50 ± 1.99 mm vs. 9.99 ± 2.52 mm, p = .039) and AV (519.37 ± 258.38 mm3 vs. 700.99 ± 346.53 mm3, p < .001) were significantly lower in the perforation group. The shrinkage of graft material from T1 to T2, including ΔESBG (p = .002), ΔNBH (p < .001) and ΔAV (p < .001), was higher in the perforation group. CONCLUSIONS: SMP during LSFE with simultaneous implant placement is associated with greater resorption of the grafted area at a 6-month follow-up.


Assuntos
Implantes Absorvíveis , Tomografia Computadorizada de Feixe Cônico , Levantamento do Assoalho do Seio Maxilar , Humanos , Levantamento do Assoalho do Seio Maxilar/métodos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Membranas Artificiais , Idoso , Implantação Dentária Endóssea/métodos , Adulto , Implantes Dentários
17.
Int J Med Sci ; 21(2): 404-412, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38169581

RESUMO

Atherosclerosis, a chronic inflammation of blood vessel walls, is a progressive pathophysiological process characterized by lipid deposition and innate adaptive immune responses. Arteriosclerosis often leads to narrowing of blood vessels. At present, interventional stent therapy is the main treatment method for vascular stenosis, which has the advantages of less trauma, less risk and faster recovery. However, atherosclerosis occurs in a complex pathophysiological environment. Stenting inevitably causes local tissue damage, leading to complications such as inflammation, intimal hyperplasia, late thrombosis, stent restenosis and other complications. It is urgent to optimize interventional therapy program. This article summarizes the advantages and disadvantages of absorbable metal scaffolds and the research progress of absorbable polymer scaffolds. The optimization strategy of stent is proposed. The status quo of drug coating was summarized. The prospect of new stent. To improve the therapeutic effect of arteriosclerosis.


Assuntos
Aterosclerose , Trombose , Humanos , Implantes Absorvíveis , Stents/efeitos adversos , Trombose/etiologia , Inflamação/complicações
18.
Int Urogynecol J ; 35(3): 713-722, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38430238

RESUMO

INTRODUCTION AND HYPOTHESIS: Fully absorbable implants may be an alternative to permanent meshes in the correction pf pelvic organ prolapse (POP) as they may reduce adverse events by promoting tissue regeneration and collagen metabolism. This study was aimed at evaluating the long-term host and biomechanical response to a fully absorbable poly-4-hydroxybutyrate (P4HB) scaffold in comparison with polypropylene (PP) mesh. METHODS: Poly-4-hydroxybutyrate scaffold (n = 16) and PP mesh (n = 16) were surgically implanted in the posterior vaginal wall of parous female Dohne Merino sheep. Vaginal explants were evaluated in terms of gross necropsy, host response (immune response, collagen deposition, tissue regeneration), biomechanics, and degradation of P4HB at 12 and 24 months post-implantation. RESULTS: Gross necropsy revealed no infection or fluid collection using P4HB or PP. At 12 months, exposures were observed with both P4HB (3 out of 8) and PP (4 out of 8), whereas at 24 months, exposures were observed only with PP (4 out of 8). The tensile stiffness of the P4HB explants was maintained over time despite complete absorption of P4HB. The collagen amount of the vaginal tissue after P4HB implantation increased over time and was significantly higher than PP at 24 months. P4HB scaffolds exhibited significantly lower myofibroblast differentiation than PP meshes at 24 months. CONCLUSIONS: The P4HB scaffold allowed for gradual load transfer to the vaginal wall and resulted in mechanically self-sufficient tissue. P4HB scaffold had a more favorable host response than PP mesh, with higher collagen content, lower myofibroblastic differentiation, and no exposures at 24 months. P4HB scaffolds have potential as an alternative to permanent implants in treating POP.


Assuntos
Prolapso de Órgão Pélvico , Feminino , Humanos , Prolapso de Órgão Pélvico/cirurgia , Prolapso de Órgão Pélvico/metabolismo , Vagina/cirurgia , Vagina/metabolismo , Colágeno/metabolismo , Implantes Absorvíveis , Cicatrização , Telas Cirúrgicas/efeitos adversos
19.
Ann Hepatol ; 29(5): 101530, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39033929

RESUMO

INTRODUCTION AND OBJECTIVES: There are different situations in which an extrahepatic bile duct replacement or substitute is needed, such as initial and localized stages of bile duct cancer, agenesis, stenosis, or bile duct disruption. MATERIALS AND METHODS: A prosthesis obtained by electrospinning composed of Poly (D,L-lactide-co-glycolide) (PGLA) - Polycaprolactone (PCL) - Gelatin (Gel) was developed, mechanical and biological tests were carried out to evaluate resistance to tension, biocompatibility, biodegradability, cytotoxicity, morphological analysis and cell culture. The obtained prosthesis was placed in the extrahepatic bile duct of 15 pigs with a 2-year follow-up. Liver function tests and cholangioscopy were evaluated during follow-up. RESULTS: Mechanical and biological evaluations indicate that this scaffold is biocompatible and biodegradable. The prosthesis implanted in the experimental model allowed cell adhesion, migration, and proliferation, maintaining bile duct permeability without altering liver function tests. Immunohistochemical analysis indicates the presence of biliary epithelium. CONCLUSIONS: A tubular scaffold composed of electrospun PGLA-PCL-Gel nanofibers was used for the first time to replace the extrahepatic bile duct in pigs. Mechanical and biological evaluations indicate that this scaffold is biocompatible and biodegradable, making it an excellent candidate for use in bile ducts and potentially in other tissue engineering applications.


Assuntos
Implantes Absorvíveis , Ductos Biliares Extra-Hepáticos , Gelatina , Poliésteres , Engenharia Tecidual , Alicerces Teciduais , Animais , Ductos Biliares Extra-Hepáticos/cirurgia , Engenharia Tecidual/métodos , Suínos , Teste de Materiais , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Proliferação de Células , Desenho de Prótese , Materiais Biocompatíveis , Movimento Celular , Adesão Celular , Fatores de Tempo , Testes de Função Hepática , Nanofibras
20.
BMC Pulm Med ; 24(1): 238, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750487

RESUMO

BACKGROUND: Biodegradable (BD) stents made from polydioxanone have been used only in human airways. These stents combine the advantages of classical tracheal stents, and fewer side effects are expected due to their biocompatibility and their time-limited presence in airways. However, new clinical consequences have arisen. Here, the authors share their experiences with BD stents for tracheal indications, focusing on their safety and efficacy. METHODS: This was a retrospective review of a collected database of adult patients who underwent implantation of biodegradable tracheal stents between September 2013 and December 2022 at the Department of Respiratory Medicine of the 1st Faculty of Medicine in Prague and Thomayer University Hospital. The indications included functionally significant nonmalignant tracheal stenosis and tracheomalacia. Self-expandable, biodegradable, polydioxanone tracheal stents manufactured by ELLA-CS Ltd. (Hradec Kralove, Czech Republic) were implanted during rigid bronchoscopy under general anaesthesia. All patients were followed up in the department and were provided with the necessary care. The main efficacy and safety parameters and relationships were analysed using descriptive statistics and Fisher´s exact, Wilcoxon and Kruskal‒Wallis tests. RESULTS: A total of 65 stents were implanted in 47 adult patients. During the first two months after implantation, when adequate function was expected, the stent was found to be effective in 26 out of 39 patients who completed this period (66.7%). The clinical effectiveness reached 89.7%, as early restenoses were mostly mild and necessitated treatment in only 4 patients. The frequencies of significant mucostasis, migration and granulation tissue growth were 2.6%, 7.5% and 23.1%, respectively, during this period. Thirty-four participants completed the half-year follow-up period after the first or second stent insertion, and some were followed up beyond this period. Poor control of symptoms, the development of restenosis and the need for interventions were characteristic of this period as the stents degraded. Twenty-two patients who experienced remodelling or stabilization of the tracheal lumen achieved a stent-free state. Seven patients underwent subsequent surgical treatment. CONCLUSIONS: BD stents are safe and provide adequate tracheal support until they begin to degrade. The use of BD stents necessitates close monitoring of patients and accurate treatment of possible restenosis. TRIAL REGISTRATION: Based on project NT14146 - Biodegradable stents in the management of the large airways (2013-2015, MZ0/NT), registered on May 1, 2013, in the Research and Development and Innovation Information System of the Czech Republic and at ClinicalTrials.gov (reg. no. NCT02620319, December 2, 2015).


Assuntos
Implantes Absorvíveis , Broncoscopia , Stents , Estenose Traqueal , Humanos , Pessoa de Meia-Idade , Masculino , Feminino , Estudos Retrospectivos , Adulto , Estenose Traqueal/cirurgia , Idoso , Polidioxanona , Traqueomalácia/cirurgia , República Tcheca , Resultado do Tratamento , Traqueia/cirurgia , Desenho de Prótese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa