Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.417
Filtrar
Mais filtros

Coleção SES
Intervalo de ano de publicação
1.
N Engl J Med ; 389(13): 1180-1190, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37754283

RESUMO

BACKGROUND: Randomized, controlled trials have shown both benefit and harm from tight blood-glucose control in patients in the intensive care unit (ICU). Variation in the use of early parenteral nutrition and in insulin-induced severe hypoglycemia might explain this inconsistency. METHODS: We randomly assigned patients, on ICU admission, to liberal glucose control (insulin initiated only when the blood-glucose level was >215 mg per deciliter [>11.9 mmol per liter]) or to tight glucose control (blood-glucose level targeted with the use of the LOGIC-Insulin algorithm at 80 to 110 mg per deciliter [4.4 to 6.1 mmol per liter]); parenteral nutrition was withheld in both groups for 1 week. Protocol adherence was determined according to glucose metrics. The primary outcome was the length of time that ICU care was needed, calculated on the basis of time to discharge alive from the ICU, with death accounted for as a competing risk; 90-day mortality was the safety outcome. RESULTS: Of 9230 patients who underwent randomization, 4622 were assigned to liberal glucose control and 4608 to tight glucose control. The median morning blood-glucose level was 140 mg per deciliter (interquartile range, 122 to 161) with liberal glucose control and 107 mg per deciliter (interquartile range, 98 to 117) with tight glucose control. Severe hypoglycemia occurred in 31 patients (0.7%) in the liberal-control group and 47 patients (1.0%) in the tight-control group. The length of time that ICU care was needed was similar in the two groups (hazard ratio for earlier discharge alive with tight glucose control, 1.00; 95% confidence interval, 0.96 to 1.04; P = 0.94). Mortality at 90 days was also similar (10.1% with liberal glucose control and 10.5% with tight glucose control, P = 0.51). Analyses of eight prespecified secondary outcomes suggested that the incidence of new infections, the duration of respiratory and hemodynamic support, the time to discharge alive from the hospital, and mortality in the ICU and hospital were similar in the two groups, whereas severe acute kidney injury and cholestatic liver dysfunction appeared less prevalent with tight glucose control. CONCLUSIONS: In critically ill patients who were not receiving early parenteral nutrition, tight glucose control did not affect the length of time that ICU care was needed or mortality. (Funded by the Research Foundation-Flanders and others; TGC-Fast ClinicalTrials.gov number, NCT03665207.).


Assuntos
Glicemia , Estado Terminal , Controle Glicêmico , Insulina , Humanos , Glicemia/análise , Glucose/análise , Hipoglicemia/induzido quimicamente , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Unidades de Terapia Intensiva , Controle Glicêmico/efeitos adversos , Controle Glicêmico/métodos , Nutrição Parenteral , Algoritmos , Estado Terminal/terapia
2.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36920756

RESUMO

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Criança , Pré-Escolar , Humanos , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos
3.
N Engl J Med ; 389(17): 1566-1578, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37796241

RESUMO

BACKGROUND: Hybrid closed-loop insulin therapy has shown promise for management of type 1 diabetes during pregnancy; however, its efficacy is unclear. METHODS: In this multicenter, controlled trial, we randomly assigned pregnant women with type 1 diabetes and a glycated hemoglobin level of at least 6.5% at nine sites in the United Kingdom to receive standard insulin therapy or hybrid closed-loop therapy, with both groups using continuous glucose monitoring. The primary outcome was the percentage of time in the pregnancy-specific target glucose range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]) as measured by continuous glucose monitoring from 16 weeks' gestation until delivery. Analyses were performed according to the intention-to-treat principle. Key secondary outcomes were the percentage of time spent in a hyperglycemic state (glucose level >140 mg per deciliter), overnight time in the target range, the glycated hemoglobin level, and safety events. RESULTS: A total of 124 participants with a mean (±SD) age of 31.1±5.3 years and a mean baseline glycated hemoglobin level of 7.7±1.2% underwent randomization. The mean percentage of time that the maternal glucose level was in the target range was 68.2±10.5% in the closed-loop group and 55.6±12.5% in the standard-care group (mean adjusted difference, 10.5 percentage points; 95% confidence interval [CI], 7.0 to 14.0; P<0.001). Results for the secondary outcomes were consistent with those of the primary outcome; participants in the closed-loop group spent less time in a hyperglycemic state than those in the standard-care group (difference, -10.2 percentage points; 95% CI, -13.8 to -6.6); had more overnight time in the target range (difference, 12.3 percentage points; 95% CI, 8.3 to 16.2), and had lower glycated hemoglobin levels (difference, -0.31 percentage points; 95% CI, -0.50 to -0.12). Little time was spent in a hypoglycemic state. No unanticipated safety problems associated with the use of closed-loop therapy during pregnancy occurred (6 instances of severe hypoglycemia, vs. 5 in the standard-care group; 1 instance of diabetic ketoacidosis in each group; and 12 device-related adverse events in the closed-loop group, 7 related to closed-loop therapy). CONCLUSIONS: Hybrid closed-loop therapy significantly improved maternal glycemic control during pregnancy complicated by type 1 diabetes. (Funded by the Efficacy and Mechanism Evaluation Program; AiDAPT ISRCTN Registry number, ISRCTN56898625.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Gravidez em Diabéticas , Adulto , Feminino , Humanos , Gravidez , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Gravidez em Diabéticas/sangue , Gravidez em Diabéticas/tratamento farmacológico , Resultado do Tratamento
4.
N Engl J Med ; 389(23): 2151-2161, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37861217

RESUMO

BACKGROUND: Teplizumab, a humanized monoclonal antibody to CD3 on T cells, is approved by the Food and Drug Administration to delay the onset of clinical type 1 diabetes (stage 3) in patients 8 years of age or older with preclinical (stage 2) disease. Whether treatment with intravenous teplizumab in patients with newly diagnosed type 1 diabetes can prevent disease progression is unknown. METHODS: In this phase 3, randomized, placebo-controlled trial, we assessed ß-cell preservation, clinical end points, and safety in children and adolescents who were assigned to receive teplizumab or placebo for two 12-day courses. The primary end point was the change from baseline in ß-cell function, as measured by stimulated C-peptide levels at week 78. The key secondary end points were the insulin doses that were required to meet glycemic goals, glycated hemoglobin levels, time in the target glucose range, and clinically important hypoglycemic events. RESULTS: Patients treated with teplizumab (217 patients) had significantly higher stimulated C-peptide levels than patients receiving placebo (111 patients) at week 78 (least-squares mean difference, 0.13 pmol per milliliter; 95% confidence interval [CI], 0.09 to 0.17; P<0.001), and 94.9% (95% CI, 89.5 to 97.6) of patients treated with teplizumab maintained a clinically meaningful peak C-peptide level of 0.2 pmol per milliliter or greater, as compared with 79.2% (95% CI, 67.7 to 87.4) of those receiving placebo. The groups did not differ significantly with regard to the key secondary end points. Adverse events occurred primarily in association with administration of teplizumab or placebo and included headache, gastrointestinal symptoms, rash, lymphopenia, and mild cytokine release syndrome. CONCLUSIONS: Two 12-day courses of teplizumab in children and adolescents with newly diagnosed type 1 diabetes showed benefit with respect to the primary end point of preservation of ß-cell function, but no significant differences between the groups were observed with respect to the secondary end points. (Funded by Provention Bio and Sanofi; PROTECT ClinicalTrials.gov number, NCT03875729.).


Assuntos
Anticorpos Monoclonais Humanizados , Diabetes Mellitus Tipo 1 , Adolescente , Criança , Humanos , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais Humanizados/farmacologia , Anticorpos Monoclonais Humanizados/uso terapêutico , Peptídeo C/análise , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/imunologia , Diabetes Mellitus Tipo 1/terapia , Método Duplo-Cego , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Linfócitos T/efeitos dos fármacos , Linfócitos T/imunologia , Complexo CD3/antagonistas & inibidores , Complexo CD3/imunologia , Progressão da Doença , Células Secretoras de Insulina/efeitos dos fármacos , Células Secretoras de Insulina/imunologia , Insulina/administração & dosagem , Insulina/uso terapêutico
5.
N Engl J Med ; 386(3): 209-219, 2022 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-35045227

RESUMO

BACKGROUND: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. METHODS: In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. RESULTS: A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was -8.5 percentage points (95% CI, -9.9 to -7.1), the difference in the glycated hemoglobin level was -0.4 percentage points (95% CI, -0.5 to -0.3), and the difference in the mean sensor glucose level was -12.3 mg per deciliter (95% CI, -14.8 to -9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P = 0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. CONCLUSIONS: A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico/instrumentação , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Algoritmos , Glicemia/análise , Criança , Pré-Escolar , Estudos Cross-Over , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Controle Glicêmico/métodos , Humanos , Hiperglicemia/diagnóstico , Lactente , Masculino
6.
N Engl J Med ; 387(10): 869-881, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36069869

RESUMO

BACKGROUND: Open-source automated insulin delivery (AID) systems are used by many patients with type 1 diabetes. Data are needed on the efficacy and safety of an open-source AID system. METHODS: In this multicenter, open-label, randomized, controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio to use an open-source AID system or a sensor-augmented insulin pump (control). The patients included both children (defined as 7 to 15 years of age) and adults (defined as 16 to 70 years of age). The AID system was a modified version of AndroidAPS 2.8 (with a standard OpenAPS 0.7.0 algorithm) paired with a preproduction DANA-i insulin pump and Dexcom G6 CGM, which has an Android smartphone application as the user interface. The primary outcome was the percentage of time in the target glucose range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) between days 155 and 168 (the final 2 weeks of the trial). RESULTS: A total of 97 patients (48 children and 49 adults) underwent randomization (44 to open-source AID and 53 to the control group). At 24 weeks, the mean (±SD) time in the target range increased from 61.2±12.3% to 71.2±12.1% in the AID group and decreased from 57.7±14.3% to 54.5±16.0% in the control group (adjusted difference, 14 percentage points; 95% confidence interval, 9.2 to 18.8; P<0.001), with no treatment effect according to age (P = 0.56). Patients in the AID group spent 3 hours 21 minutes more in the target range per day than those in the control group. No severe hypoglycemia or diabetic ketoacidosis occurred in either group. Two patients in the AID group withdrew from the trial owing to connectivity issues. CONCLUSIONS: In children and adults with type 1 diabetes, the use of an open-source AID system resulted in a significantly higher percentage of time in the target glucose range than the use of a sensor-augmented insulin pump at 24 weeks. (Supported by the Health Research Council of New Zealand; Australian New Zealand Clinical Trials Registry number, ACTRN12620000034932.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Bombas de Infusão , Insulina , Adolescente , Adulto , Idoso , Austrália , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Pessoa de Meia-Idade , Adulto Jovem
7.
N Engl J Med ; 387(16): 1477-1487, 2022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36198143

RESUMO

BACKGROUND: In persons with type 1 diabetes and high glycated hemoglobin levels, the benefits of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels are uncertain. METHODS: In a parallel-group, multicenter, randomized, controlled trial involving participants with type 1 diabetes and glycated hemoglobin levels between 7.5% and 11.0%, we investigated the efficacy of intermittently scanned continuous glucose monitoring as compared with participant monitoring of blood glucose levels with fingerstick testing. The primary outcome was the glycated hemoglobin level at 24 weeks, analyzed according to the intention-to-treat principle. Key secondary outcomes included sensor data, participant-reported outcome measures, and safety. RESULTS: A total of 156 participants were randomly assigned, in a 1:1 ratio, to undergo intermittently scanned continuous glucose monitoring (the intervention group, 78 participants) or to monitor their own blood glucose levels with fingerstick testing (the usual-care group, 78 participants). At baseline, the mean (±SD) age of the participants was 44±15 years, and the mean duration of diabetes was 21±13 years; 44% of the participants were women. The mean baseline glycated hemoglobin level was 8.7±0.9% in the intervention group and 8.5±0.8% in the usual-care group; these levels decreased to 7.9±0.8% and 8.3±0.9%, respectively, at 24 weeks (adjusted mean between-group difference, -0.5 percentage points; 95% confidence interval [CI], -0.7 to -0.3; P<0.001). The time per day that the glucose level was in the target range was 9.0 percentage points (95% CI, 4.7 to 13.3) higher or 130 minutes (95% CI, 68 to 192) longer in the intervention group than in the usual-care group, and the time spent in a hypoglycemic state (blood glucose level, <70 mg per deciliter [<3.9 mmol per liter]) was 3.0 percentage points (95% CI, 1.4 to 4.5) lower or 43 minutes (95% CI, 20 to 65) shorter in the intervention group. Two participants in the usual-care group had an episode of severe hypoglycemia, and 1 participant in the intervention group had a skin reaction to the sensor. CONCLUSIONS: Among participants with type 1 diabetes and high glycated hemoglobin levels, the use of intermittently scanned continuous glucose monitoring with optional alarms for high and low blood glucose levels resulted in significantly lower glycated hemoglobin levels than levels monitored by fingerstick testing. (Funded by Diabetes UK and others; FLASH-UK ClinicalTrials.gov number, NCT03815006.).


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
8.
N Engl J Med ; 387(13): 1161-1172, 2022 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-36170500

RESUMO

BACKGROUND: Currently available semiautomated insulin-delivery systems require individualized insulin regimens for the initialization of therapy and meal doses based on carbohydrate counting for routine operation. In contrast, the bionic pancreas is initialized only on the basis of body weight, makes all dose decisions and delivers insulin autonomously, and uses meal announcements without carbohydrate counting. METHODS: In this 13-week, multicenter, randomized trial, we randomly assigned in a 2:1 ratio persons at least 6 years of age with type 1 diabetes either to receive bionic pancreas treatment with insulin aspart or insulin lispro or to receive standard care (defined as any insulin-delivery method with unblinded, real-time continuous glucose monitoring). The primary outcome was the glycated hemoglobin level at 13 weeks. The key secondary outcome was the percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter; the prespecified noninferiority limit for this outcome was 1 percentage point. Safety was also assessed. RESULTS: A total of 219 participants 6 to 79 years of age were assigned to the bionic-pancreas group, and 107 to the standard-care group. The glycated hemoglobin level decreased from 7.9% to 7.3% in the bionic-pancreas group and did not change (was at 7.7% at both time points) in the standard-care group (mean adjusted difference at 13 weeks, -0.5 percentage points; 95% confidence interval [CI], -0.6 to -0.3; P<0.001). The percentage of time that the glucose level as assessed by continuous glucose monitoring was below 54 mg per deciliter did not differ significantly between the two groups (13-week adjusted difference, 0.0 percentage points; 95% CI, -0.1 to 0.04; P<0.001 for noninferiority). The rate of severe hypoglycemia was 17.7 events per 100 participant-years in the bionic-pancreas group and 10.8 events per 100 participant-years in the standard-care group (P = 0.39). No episodes of diabetic ketoacidosis occurred in either group. CONCLUSIONS: In this 13-week, randomized trial involving adults and children with type 1 diabetes, use of a bionic pancreas was associated with a greater reduction than standard care in the glycated hemoglobin level. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; ClinicalTrials.gov number, NCT04200313.).


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina Aspart , Sistemas de Infusão de Insulina , Insulina Lispro , Adolescente , Adulto , Idoso , Biônica/instrumentação , Glicemia/análise , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Insulina Aspart/administração & dosagem , Insulina Aspart/efeitos adversos , Insulina Aspart/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos , Insulina Lispro/administração & dosagem , Insulina Lispro/efeitos adversos , Insulina Lispro/uso terapêutico , Pessoa de Meia-Idade , Adulto Jovem
9.
Proc Natl Acad Sci U S A ; 119(33): e2207829119, 2022 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-35943988

RESUMO

Although patients generally prefer oral drug delivery to injections, low permeability of the gastrointestinal tract makes this method impossible for most biomacromolecules. One potential solution is codelivery of macromolecules, including therapeutic proteins or nucleic acids, with intestinal permeation enhancers; however, enhancer use has been limited clinically by modest efficacy and toxicity concerns surrounding long-term administration. Here, we hypothesized that plant-based foods, which are well tolerated by the gastrointestinal tract, may contain compounds that enable oral macromolecular absorption without causing adverse effects. Upon testing more than 100 fruits, vegetables, and herbs, we identified strawberry and its red pigment, pelargonidin, as potent, well-tolerated enhancers of intestinal permeability. In mice, an oral capsule formulation comprising pelargonidin and a 1 U/kg dose of insulin reduced blood glucose levels for over 4 h, with bioactivity exceeding 100% relative to subcutaneous injection. Effects were reversible within 2 h and associated with actin and tight junction rearrangement. Furthermore, daily dosing of mice with pelargonidin for 1 mo resulted in no detectable side effects, including weight loss, tissue damage, or inflammatory responses. These data suggest that pelargonidin is an exceptionally effective enhancer of oral protein uptake that may be safe for routine pharmaceutical use.


Assuntos
Antocianinas , Fragaria , Absorção Intestinal , Intestinos , Proteínas , Administração Oral , Animais , Antocianinas/química , Antocianinas/farmacologia , Fragaria/química , Insulina/administração & dosagem , Insulina/farmacocinética , Absorção Intestinal/efeitos dos fármacos , Intestinos/efeitos dos fármacos , Intestinos/metabolismo , Camundongos , Permeabilidade , Proteínas/administração & dosagem , Proteínas/farmacocinética
10.
Diabetologia ; 67(6): 1009-1022, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38502241

RESUMO

AIMS/HYPOTHESIS: Adults with type 1 diabetes should perform daily physical activity to help maintain health and fitness, but the influence of daily step counts on continuous glucose monitoring (CGM) metrics are unclear. This analysis used the Type 1 Diabetes Exercise Initiative (T1DEXI) dataset to investigate the effect of daily step count on CGM-based metrics. METHODS: In a 4 week free-living observational study of adults with type 1 diabetes, with available CGM and step count data, we categorised participants into three groups-below (<7000), meeting (7000-10,000) or exceeding (>10,000) the daily step count goal-to determine if step count category influenced CGM metrics, including per cent time in range (TIR: 3.9-10.0 mmol/l), time below range (TBR: <3.9 mmol/l) and time above range (TAR: >10.0 mmol/l). RESULTS: A total of 464 adults with type 1 diabetes (mean±SD age 37±14 years; HbA1c 48.8±8.1 mmol/mol [6.6±0.7%]; 73% female; 45% hybrid closed-loop system, 38% standard insulin pump, 17% multiple daily insulin injections) were included in the study. Between-participant analyses showed that individuals who exceeded the mean daily step count goal over the 4 week period had a similar TIR (75±14%) to those meeting (74±14%) or below (75±16%) the step count goal (p>0.05). In the within-participant comparisons, TIR was higher on days when the step count goal was exceeded or met (both 75±15%) than on days below the step count goal (73±16%; both p<0.001). The TBR was also higher when individuals exceeded the step count goals (3.1%±3.2%) than on days when they met or were below step count goals (difference in means -0.3% [p=0.006] and -0.4% [p=0.001], respectively). The total daily insulin dose was lower on days when step count goals were exceeded (0.52±0.18 U/kg; p<0.001) or were met (0.53±0.18 U/kg; p<0.001) than on days when step counts were below the current recommendation (0.55±0.18 U/kg). Step count had a larger effect on CGM-based metrics in participants with a baseline HbA1c ≥53 mmol/mol (≥7.0%). CONCLUSIONS/INTERPRETATION: Our results suggest that, compared with days with low step counts, days with higher step counts are associated with slight increases in both TIR and TBR, along with small reductions in total daily insulin requirements, in adults living with type 1 diabetes. DATA AVAILABILITY: The data that support the findings reported here are available on the Vivli Platform (ID: T1-DEXI; https://doi.org/10.25934/PR00008428 ).


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Exercício Físico , Humanos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Adulto , Feminino , Masculino , Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Glicemia/análise , Pessoa de Meia-Idade , Exercício Físico/fisiologia , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Insulina/uso terapêutico , Insulina/administração & dosagem , Estudos de Coortes , Monitoramento Contínuo da Glicose
11.
Diabetologia ; 67(6): 1095-1106, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38427076

RESUMO

AIMS/HYPOTHESIS: As a result of early loss of the glucagon response, adrenaline is the primary counter-regulatory hormone in type 1 diabetes. Diminished adrenaline responses to hypoglycaemia due to counter-regulatory failure are common in type 1 diabetes, and are probably induced by exposure to recurrent hypoglycaemia, however, the metabolic effects of adrenaline have received less research attention, and also there is conflicting evidence regarding adrenaline sensitivity in type 1 diabetes. Thus, we aimed to investigate the metabolic response to adrenaline and explore whether it is modified by prior exposure to hypoglycaemia. METHODS: Eighteen participants with type 1 diabetes and nine healthy participants underwent a three-step ascending adrenaline infusion during a hyperinsulinaemic-euglycaemic clamp. Continuous glucose monitoring data obtained during the week before the study day were used to assess the extent of hypoglycaemia exposure. RESULTS: While glucose responses during the clamp were similar between people with type 1 diabetes and healthy participants, plasma concentrations of NEFAs and glycerol only increased in the group with type 1 diabetes (p<0.001). Metabolomics revealed an increase in the most common NEFAs (p<0.01). Other metabolic responses were generally similar between participants with type 1 diabetes and healthy participants. Exposure to hypoglycaemia was negatively associated with the NEFA response; however, this was not statistically significant. CONCLUSIONS/INTERPRETATION: In conclusion, individuals with type 1 diabetes respond with increased lipolysis to adrenaline compared with healthy participants by mobilising the abundant NEFAs in plasma, whereas other metabolic responses were similar. This may suggest that the metabolic sensitivity to adrenaline is altered in a pathway-specific manner in type 1 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov NCT05095259.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Epinefrina , Técnica Clamp de Glucose , Hipoglicemia , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 1/sangue , Epinefrina/sangue , Epinefrina/administração & dosagem , Ácidos Graxos não Esterificados/sangue , Glucagon/sangue , Glicerol/sangue , Glicerol/administração & dosagem , Hipoglicemia/sangue , Insulina/administração & dosagem , Estudos de Casos e Controles
12.
Diabetologia ; 67(7): 1223-1234, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38639876

RESUMO

AIMS/HYPOTHESIS: The aim of this study was to compare the effectiveness of stand-alone intermittently scanned continuous glucose monitoring (isCGM) with or without a structured education programme and blood glucose monitoring (BGM) in adults with type 2 diabetes on multiple daily insulin injections (MDI). METHODS: In this 24 week randomised open-label multicentre trial, adults with type 2 diabetes on intensive insulin therapy with HbA1c levels of 58-108 mmol/mol (7.5-12.0%) were randomly assigned in a 1:1:1 ratio to isCGM with a structured education programme on adjusting insulin dose and timing according to graphical patterns in CGM (intervention group), isCGM with conventional education (control group 1) or BGM with conventional education (control group 2). Block randomisation was conducted by an independent statistician. Due to the nature of the intervention, blinding of participants and investigators was not possible. The primary outcome was change in HbA1c from baseline at 24 weeks, assessed using ANCOVA with the baseline value as a covariate. RESULTS: A total of 159 individuals were randomised (n=53 for each group); 148 were included in the full analysis set, with 52 in the intervention group, 49 in control group 1 and 47 in control group 2. The mean (± SD) HbA1c level at baseline was 68.19±10.94 mmol/mol (8.39±1.00%). The least squares mean change (± SEM) from baseline HbA1c at 24 weeks was -10.96±1.35 mmol/mol (-1.00±0.12%) in the intervention group, -6.87±1.39 mmol/mol (-0.63±0.13%) in control group 1 (p=0.0367 vs intervention group) and -6.32±1.42 mmol/mol (-0.58±0.13%) in control group 2 (p=0.0193 vs intervention group). Adverse events occurred in 28.85% (15/52) of individuals in the intervention group, 26.42% (14/53) in control group 1 and 48.08% (25/52) in control group 2. CONCLUSIONS/INTERPRETATION: Stand-alone isCGM offers a greater reduction in HbA1c in adults with type 2 diabetes on MDI when education on the interpretation of graphical patterns in CGM is provided. TRIAL REGISTRATION: ClinicalTrials.gov NCT04926623. FUNDING: This study was supported by Daewoong Pharmaceutical Co., Ltd.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Hipoglicemiantes , Insulina , Educação de Pacientes como Assunto , Humanos , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Automonitorização da Glicemia/métodos , Insulina/administração & dosagem , Insulina/uso terapêutico , Glicemia/metabolismo , Glicemia/efeitos dos fármacos , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Educação de Pacientes como Assunto/métodos , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Idoso , Adulto , Monitoramento Contínuo da Glicose
13.
Diabetologia ; 67(7): 1235-1244, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38634887

RESUMO

AIMS/HYPOTHESIS: This study compares the efficacy and safety of a tubeless, on-body automated insulin delivery (AID) system with that of a tubeless, on-body sensor-augmented pump (SAP). METHODS: This multicentre, parallel-group, RCT was conducted at 13 tertiary medical centres in South Korea. Adults aged 19-69 years with type 1 diabetes who had HbA1c levels of <85.8 mmol/mol (<10.0%) were eligible. The participants were assigned at a 1:1 ratio to receive a tubeless, on-body AID system (intervention group) or a tubeless, on-body SAP (control group) for 12 weeks. Stratified block randomisation was conducted by an independent statistician. Blinding was not possible due to the nature of the intervention. The primary outcome was the percentage of time in range (TIR), blood glucose between 3.9 and 10.0 mmol/l, as measured by continuous glucose monitoring. ANCOVAs were conducted with baseline values and study centres as covariates. RESULTS: A total of 104 participants underwent randomisation, with 53 in the intervention group and 51 in the control group. The mean (±SD) age of the participants was 40±11 years. The mean (±SD) TIR increased from 62.1±17.1% at baseline to 71.5±10.7% over the 12 week trial period in the intervention group and from 64.7±17.0% to 66.9±15.0% in the control group (difference between the adjusted means: 6.5% [95% CI 3.6%, 9.4%], p<0.001). Time below range, time above range, CV and mean glucose levels were also significantly better in the intervention group compared with the control group. HbA1c decreased from 50.9±9.9 mmol/mol (6.8±0.9%) at baseline to 45.9±7.4 mmol/mol (6.4±0.7%) after 12 weeks in the intervention group and from 48.7±9.1 mmol/mol (6.6±0.8%) to 45.7±7.5 mmol/mol (6.3±0.7%) in the control group (difference between the adjusted means: -0.7 mmol/mol [95% CI -2.0, 0.8 mmol/mol] (-0.1% [95% CI -0.2%, 0.1%]), p=0.366). No diabetic ketoacidosis or severe hypoglycaemia events occurred in either group. CONCLUSIONS/INTERPRETATION: The use of a tubeless, on-body AID system was safe and associated with superior glycaemic profiles, including TIR, time below range, time above range and CV, than the use of a tubeless, on-body SAP. TRIAL REGISTRATION: Clinical Research Information Service (CRIS) KCT0008398 FUNDING: The study was funded by a grant from the Korea Medical Device Development Fund supported by the Ministry of Science and ICT; the Ministry of Trade, Industry and Energy; the Ministry of Health and Welfare; and the Ministry of Food and Drug Safety (grant number: RS-2020-KD000056).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Masculino , Pessoa de Meia-Idade , Adulto , Feminino , Insulina/administração & dosagem , Insulina/uso terapêutico , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Idoso , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , República da Coreia , Automonitorização da Glicemia/métodos , Adulto Jovem
14.
Am J Physiol Endocrinol Metab ; 326(5): E673-E680, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446636

RESUMO

Residual beta cells are present in most patients with longstanding type 1 diabetes but it is unknown whether these beta cells react normally to different stimuli. Moreover a defect in proinsulin conversion and abnormal alpha cell response are also part of the islet dysfunction. A three-phase [euglycemia, hyperglycemia, and hyperglycemia + glucagon-like peptide 1 (GLP-1)] clamp was performed in patients with longstanding type 1 diabetes. Intravenous arginine boluses were administered at the end of each phase. On another day, a mixed meal stimulation test with a subsequent intravenous arginine bolus was performed. C-peptide was detectable in a subgroup of subjects at baseline (2/15) or only after stimulation (3/15). When detectable, C-peptide increased 2.9-fold [95% CI: 1.2-7.1] during the hyperglycemia phase and 14.1-fold [95% CI: 3.1-65.2] during the hyperglycemia + GLP-1 phase, and 22.3-fold [95% CI: 5.6-89.1] during hyperglycemia + GLP-1 + arginine phase when compared with baseline. The same subset of patients with a C-peptide response were identified during the mixed meal stimulation test as during the clamp. There was an inhibition of glucagon secretion (0.72-fold, [95% CI: 0.63-0.84]) during the glucose clamp irrespective of the presence of detectable beta cell function. Proinsulin was only present in a subset of subjects with detectable C-peptide (3/15) and proinsulin mimicked the C-peptide response to the different stimuli when detectable. Residual beta cells in longstanding type 1 diabetes respond adequately to different stimuli and could be of clinical benefit.NEW & NOTEWORTHY If beta cell function is detectable, the beta cells react relatively normal to the different stimuli except for the first phase response to intravenous glucose. An oral mixed meal followed by an intravenous arginine bolus can identify residual beta cell function/mass as well as the more commonly used glucose potentiated arginine-induced insulin secretion during a hyperglycemic clamp.


Assuntos
Arginina , Peptídeo C , Diabetes Mellitus Tipo 1 , Alimentos Formulados , Peptídeo 1 Semelhante ao Glucagon , Glucose , Ilhotas Pancreáticas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arginina/administração & dosagem , Arginina/farmacologia , Glicemia/metabolismo , Peptídeo C/sangue , Peptídeo C/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Glucagon/metabolismo , Peptídeo 1 Semelhante ao Glucagon/administração & dosagem , Peptídeo 1 Semelhante ao Glucagon/metabolismo , Glucose/administração & dosagem , Glucose/metabolismo , Técnica Clamp de Glucose , Hiperglicemia/metabolismo , Insulina/metabolismo , Insulina/administração & dosagem , Células Secretoras de Insulina/metabolismo , Células Secretoras de Insulina/efeitos dos fármacos , Células Secretoras de Insulina/fisiologia , Ilhotas Pancreáticas/metabolismo , Ilhotas Pancreáticas/efeitos dos fármacos
15.
BMC Med ; 22(1): 175, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659016

RESUMO

Hybrid closed-loop (HCL) systems seamlessly interface continuous glucose monitoring (CGM) with insulin pumps, employing specialised algorithms and user-initiated automated insulin delivery. This study aimed to assess the efficacy of HCLs at 12 months post-initiation on glycated haemoglobin (HbA1c), time-in-range (TIR), hypoglycaemia frequency, and quality of life measures among children and young people (CYP) with type 1 diabetes mellitus (T1DM) and their caregivers in a real-world setting. Conducted between August 1, 2021, and December 10, 2022, the prospective recruitment took place in eight paediatric diabetes centres across England under the National Health Service England's (NHSE) HCL pilot real-world study. A cohort of 251 CYP (58% males, mean age 12.3 years) with T1DM participated (89% white, 3% Asian, 4% black, 3% mixed ethnicity, and 1% other). The study utilised three HCL systems: (1) Tandem Control-IQ AP system, which uses the Tandem t:slim X2 insulin pump (Tandem Diabetes Care, San Diego, CA, USA) with the Dexcom G6® CGM (Dexcom, San Diego, CA, USA) sensor; (2) Medtronic MiniMed™ 780G with the Guardian 4 sensor (Medtronic, Northridge, CA, USA); and (3) the CamAPS FX (CamDiab, Cambridge, UK) with the Ypsomed insulin pump (Ypsomed Ltd, Escrick, UK) and Dexcom G6® CGM.All systems were fully funded by the NHS. Results demonstrated significant improvements in HbA1c (average reduction at 12 months 7 mmol/mol; P < 0.001), time-in-range (TIR) (average increase 13.4%; P < 0.001), hypoglycaemia frequency (50% reduction), hypoglycaemia fear, and quality of sleep (P < 0.001) among CYP over a 12-month period of HCL usage. Additionally, parents and carers experienced improvements in hypoglycaemia fear and quality of sleep after 6 and 12 months of use. In addition to the improvements in glycaemic management, these findings underscore the positive impact of HCL systems on both the well-being of CYP with T1DM and the individuals caring for them.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Qualidade de Vida , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Masculino , Criança , Adolescente , Feminino , Glicemia/efeitos dos fármacos , Insulina/administração & dosagem , Insulina/uso terapêutico , Inglaterra , Automonitorização da Glicemia/métodos , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Estudos Prospectivos , Hipoglicemia , Controle Glicêmico/métodos
16.
Diabetes Metab Res Rev ; 40(5): e3826, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38824455

RESUMO

INTRODUCTION: Early and tight glycaemic control is crucial to prevent long-term complications of Type 1 Diabetes (T1D). The aim of our study was to compare glucose metrics, including Time In Tight Range (TITR), in a real-world setting. METHODS: We performed a single-centre cross-sectional study in 534 children and adolescents with T1D. Participants were divided into four groups (multiple daily injections + real-time Continuous glucose monitoring (CGM), multiple daily injections + intermittently scanned CGM, sensor augmented pump (SAP), and Advanced Hybrid Closed-Loop (AHCL). Demographical and clinical data were collected and analysed. RESULTS: The group with AHCL showed significantly higher Time In Range (TIR) (71.31% ± 10.88) than SAP (57.82% ± 14.98; p < 0.001), MDI + rtCGM (54.56% ± 17.04; p < 0.001) and MDI + isCGM (52.17% ± 19.36; p < 0.001) groups with a lower Time Above Range (p < 0.001). The group with AHCL also showed lower Time Below Range than MDI + isCGM and SAP groups (p < 0.01). The overall TITR was 37% ± 14 with 19% of participants who reached a TITR ≥50% with a mean TIR of 81%. AHCL had significantly higher TITR (45.46% ± 11.77) than SAP (36.25% ± 13.53; p < 0.001), MDI + rtCGM (34.03% ± 13.89; p < 0.001) and MDI + isCGM (33.37% ± 15.84; p < 0.001) groups with a lower Coefficient of Variation (p < 0.001). CONCLUSIONS: Our study indicates that AHCL ensures a better glycaemic control with an improvement in both TIR and TITR, along with a reduction in CV. Implementation of automated insulin delivery systems should be considered in the treatment of children and adolescents with T1D.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Estudos Transversais , Criança , Adolescente , Feminino , Masculino , Automonitorização da Glicemia/métodos , Glicemia/análise , Insulina/administração & dosagem , Insulina/uso terapêutico , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Controle Glicêmico/métodos , Hemoglobinas Glicadas/análise , Seguimentos , Prognóstico , Biomarcadores/análise , Hipoglicemia/prevenção & controle
17.
Diabet Med ; 41(7): e15339, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38679910

RESUMO

AIM: To summarise, in a narrative review, published data on hypoglycaemia occurrence with basal insulin therapy in adults with type 1 diabetes treated with basal-bolus insulin regimens in treat-to-target randomised controlled trials. METHODS: Data were included from 21 eligible trials, which mainly used self-measured blood glucose or plasma glucose to detect hypoglycaemia. RESULTS: All-day self-measured blood glucose or plasma glucose level 2 (glucose threshold of 3.1 or 3.0 mmol/L) and level 3 (severe, requiring assistance) hypoglycaemic events were reported, respectively, by a range of 69.0%-97.5% and 0%-13.4% adults when receiving basal-bolus insulin therapy, with rates of 10.6-68.1 and 0.0-0.4 events per patient-year of exposure, respectively. Hypoglycaemia rates measured using continuous glucose monitoring (three studies) were numerically, yet consistently, higher than with either other method, except when limiting to symptomatic events. Nocturnal hypoglycaemia rates were generally less than 30% of the equivalent all-day rates. CONCLUSIONS: Differences across the studies in design (e.g., titration targets) and participant characteristics hindered comparison of hypoglycaemia rates by insulin formulation. Consequently, few trends were identified by insulin formulation, study methodology or individuals' characteristics, suggesting that further research is required to identify treatment strategies that facilitate development of individualised recommendations to lower hypoglycaemia risk. These findings are useful to understand hypoglycaemia risk with available basal insulin therapies when used in a multiple daily injection regimen, as well as to provide context for the results of ongoing and future clinical trials, including those for two once-weekly basal insulins, insulin icodec and basal insulin Fc.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemia , Hipoglicemiantes , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Hipoglicemia/induzido quimicamente , Hipoglicemia/epidemiologia , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Glicemia/metabolismo , Glicemia/análise , Ensaios Clínicos Controlados Aleatórios como Assunto , Adulto , Automonitorização da Glicemia
18.
Diabet Med ; 41(7): e15342, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38687846

RESUMO

AIMS: Hyperglycaemia aversion in type 1 diabetes can be associated with severe hypoglycaemia and impaired awareness of hypoglycaemia but is not routinely assessed clinically. This study aimed to undertake the first psychometric validation of the UK version of the Hyperglycaemia Avoidance Scale (HAS-UK). METHODS: The HAS-UK was completed by adults with type 1 diabetes in three separate research studies. Psychometric properties were evaluated, using exploratory factor analysis, internal consistency, and convergent validity. RESULTS: Of the 431 participants who completed the HAS-UK in the three studies, mean age was 49.5 years, and 58.0% were women. Mean duration of diabetes was 29 years, with 192 (44.5%) using multiple daily injections and 229 (53.1%) using an insulin pump. Five participants were excluded from analyses due to incomplete HAS-UK responses. Exploratory factor analysis revealed a 3-factor solution, with acceptable internal consistency for 'worry' and 'blood glucose decisions' factors. HAS-UK total score was higher in those using insulin pumps versus multiple daily injections, and 'blood glucose decisions' score was higher in those using a continuous blood glucose sensor versus a meter. CONCLUSIONS: The HAS-UK is a reliable measure with acceptable structural validity and is likely to be useful for evaluating hyperglycaemia aversion in people with type 1 diabetes. Future research would benefit from investigating further psychometric properties including test-retest reliability, sensitivity to change, and clinical significance of scores.


Assuntos
Diabetes Mellitus Tipo 1 , Hiperglicemia , Psicometria , Humanos , Feminino , Psicometria/métodos , Masculino , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Pessoa de Meia-Idade , Adulto , Reprodutibilidade dos Testes , Hipoglicemiantes/uso terapêutico , Inquéritos e Questionários/normas , Reino Unido/epidemiologia , Insulina/administração & dosagem , Insulina/uso terapêutico , Hipoglicemia , Glicemia/metabolismo , Glicemia/análise , Análise Fatorial , Automonitorização da Glicemia , Sistemas de Infusão de Insulina , Idoso
19.
Diabet Med ; 41(6): e15307, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38383984

RESUMO

AIMS: While continuous glucose monitoring (CGM) and associated technologies have positive effects on metabolic control in young people with type 1 diabetes (T1D), less is known about their impact on quality of life (QoL). Here, we quantified CGM satisfaction and QoL in young people with T1D and their parents/caregivers to establish (i) the relationship between QoL and CGM satisfaction and (ii) the impact of the treatment regimen on QoL. METHODS: This was a cross-sectional study of children and adolescents with T1D on different treatment regimens (multiple daily injections, sensor-augmented pumps and automated insulin delivery). QoL was assessed with the KINDL instrument, and CGM satisfaction with the CGM-SAT questionnaire was evaluated in both youths with T1D and their parents. RESULTS: Two hundred and ten consecutively enrolled youths with T1D completed the KINDL and CGM-SAT questionnaires. The mean total KINDL score was greater than neutral in both subjects with T1D (3.99 ± 0.47) and parents (4.06 ± 0.40), and lower overall CGM-SAT scores (i.e., higher satisfaction) were significantly associated with higher QoL in all six KINDL subscales (p < 0.05). There were no differences in KINDL scores according to delivery technology or when participants were grouped according to optimal and sub-optimal glucose control. CONCLUSIONS: Higher satisfaction with recent CGMs was associated with better QoL in all dimensions. QoL was independent of both the insulin delivery technology and glycaemic control. CGM must be further disseminated. Attention on perceived satisfaction with CGM should be incorporated with the clinical practice to improve the well-being of children and adolescents with T1D and their families.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Satisfação do Paciente , Qualidade de Vida , Humanos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Adolescente , Masculino , Feminino , Criança , Estudos Transversais , Insulina/uso terapêutico , Insulina/administração & dosagem , Hipoglicemiantes/uso terapêutico , Controle Glicêmico , Glicemia/metabolismo , Glicemia/análise , Inquéritos e Questionários , Pais/psicologia , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Monitoramento Contínuo da Glicose
20.
Diabet Med ; 41(7): e15325, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38551326

RESUMO

OBJECTIVE: To examine the cross-sectional associations between diabetes distress, BMI (zBMI; BMI z-score), objectively measured mean daily blood glucose readings and insulin boluses administered, and A1C in adolescents with type 1 diabetes (T1D) using insulin pumps. METHODS: T1D self-management behaviour data were downloaded from adolescents' (N = 79) devices and mean daily frequency of blood glucose readings and insulin boluses were calculated. Diabetes distress was measured (Problem Areas in Diabetes-Teen questionnaire [PAID-T]), A1C collected, and zBMI calculated from height and weight. Three multiple linear regressions were performed with blood glucose readings, insulin boluses, and A1C as the three dependent variables and covariates (age, T1D duration), zBMI, diabetes distress, and the diabetes distress x zBMI interaction as independent variables. RESULTS: Participants (55.7% female) were 14.9 ± 1.9 years old with T1D for 6.6 ± 3.4 years. zBMI moderated the relationship between diabetes distress and mean daily insulin boluses administered (b = -0.02, p = 0.02); those with higher zBMI and higher diabetes distress administered fewer daily insulin boluses. zBMI was not a moderator of the association between diabetes distress and blood glucose readings (b = -0.01, p = 0.29) or A1C (b = 0.002, p = 0.81). CONCLUSIONS: Using objective behavioural data is useful for identifying how adolescent diabetes distress and zBMI affect daily bolusing behaviour amongst adolescent insulin pump users. Although distinct interventions exist to improve T1D self-management or diabetes distress, none addresses them together while considering zBMI. Decreasing diabetes distress could be especially important for youth with high zBMI.


Assuntos
Índice de Massa Corporal , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Insulina , Autogestão , Humanos , Diabetes Mellitus Tipo 1/psicologia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Adolescente , Feminino , Masculino , Estudos Transversais , Hemoglobinas Glicadas/metabolismo , Hemoglobinas Glicadas/análise , Insulina/administração & dosagem , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Hipoglicemiantes/uso terapêutico , Hipoglicemiantes/administração & dosagem , Glicemia/metabolismo , Glicemia/análise , Automonitorização da Glicemia , Angústia Psicológica , Estresse Psicológico/etiologia , Estresse Psicológico/epidemiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa