Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(47): e2214662119, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36375085

RESUMO

Second harmonic generation microscopy (SHG) is generally acknowledged as a powerful tool for the label-free three-dimensional visualization of tissues and advanced materials, with one of its most popular applications being collagen imaging. Despite the great need, progress in super-resolved SHG imaging lags behind the developments reported over the past years in fluorescence-based optical nanoscopy. In this work, we demonstrate super-resolved re-scan SHG, qualitatively and quantitatively showing on collagenous tissues the available resolution advantage over the diffraction limit. We introduce as well super-resolved re-scan two-photon excited fluorescence microscopy, an imaging modality not explored to date.


Assuntos
Microscopia de Geração do Segundo Harmônico , Microscopia de Geração do Segundo Harmônico/métodos , Microscopia de Fluorescência/métodos , Colágeno , Fótons , Cintilografia
2.
Anal Chem ; 96(23): 9353-9361, 2024 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-38810149

RESUMO

The retroperitoneal liposarcoma (RLPS) is a rare malignancy whose only curative therapy is surgical resection. However, well-differentiated liposarcomas (WDLPSs), one of its most common types, can hardly be distinguished from normal fat during operation without an effective margin assessment method, jeopardizing the prognosis severely with a high recurrence risk. Here, we combined dual label-free nonlinear optical modalities, stimulated Raman scattering (SRS) microscopy and second harmonic generation (SHG) microscopy, to image two predominant tissue biomolecules, lipids and collagen fibers, in 35 RLPSs and 34 normal fat samples collected from 35 patients. The produced dual-modal tissue images were used for RLPS diagnosis based on deep learning. Dramatically decreasing lipids and increasing collagen fibers during tumor progression were reflected. A ResNeXt101-based model achieved 94.7% overall accuracy and 0.987 mean area under the ROC curve (AUC) in differentiating among normal fat, WDLPSs, and dedifferentiated liposarcomas (DDLPSs). In particular, WDLPSs were detected with 94.1% precision and 84.6% sensitivity superior to existing methods. The ablation experiment showed that such performance was attributed to both SRS and SHG microscopies, which increased the sensitivity of recognizing WDLPS by 16.0 and 3.6%, respectively. Furthermore, we utilized this model on RLPS margins to identify the tumor infiltration. Our method holds great potential for accurate intraoperative liposarcoma detection.


Assuntos
Aprendizado Profundo , Lipossarcoma , Neoplasias Retroperitoneais , Humanos , Lipossarcoma/diagnóstico por imagem , Lipossarcoma/patologia , Lipossarcoma/diagnóstico , Neoplasias Retroperitoneais/diagnóstico por imagem , Neoplasias Retroperitoneais/patologia , Neoplasias Retroperitoneais/diagnóstico , Análise Espectral Raman/métodos , Microscopia/métodos , Microscopia de Geração do Segundo Harmônico
3.
Opt Lett ; 49(13): 3705-3708, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38950247

RESUMO

Circular dichroism second harmonic generation microscopy (CDSHG) is a powerful imaging technique, which allows three-dimensional visualization of collagen fibril orientation in tissues. However, recent publications have obtained contradictory results on whether CDSHG can be used to reveal the relative out-of-plane polarity of collagen fibrils. Here we compare CDSHG images of unstained tendon and tendon which has been stained with hematoxylin and eosin. We find significant differences in the CDSHG between these two conditions, which explain the recent contradictory results within the literature.


Assuntos
Dicroísmo Circular , Colágeno , Tendões , Colágeno/química , Tendões/diagnóstico por imagem , Tendões/química , Animais , Coloração e Rotulagem , Microscopia de Geração do Segundo Harmônico/métodos
4.
BMC Cancer ; 24(1): 652, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811917

RESUMO

BACKGROUND: Pancreatic ductal adenocarcinoma (PDAC) ranks among the deadliest types of cancer, and it will be meaningful to search for new biomarkers with prognostic value to help clinicians tailor therapeutic strategies. METHODS: Here we tried to use an advanced optical imaging technique, multiphoton microscopy (MPM) combining second-harmonic generation (SHG) and two-photon excited fluorescence (TPEF) imaging, for the label-free detection of PDAC tissues from a cohort of 149 patients. An automated image processing method was used to extract collagen features from SHG images and the Kaplan-Meier survival analysis and Cox proportional hazards regression were used to assess the prognostic value of collagen signatures. RESULTS: SHG images clearly show the different characteristics of collagen fibers in tumor microenvironment. We gained eight collagen morphological features, and a Feature-score was derived for each patient by the combination of these features using ridge regression. Statistical analyses reveal that Feature-score is an independent factor, and can predict the overall survival of PDAC patients as well as provide well risk stratification. CONCLUSIONS: SHG imaging technique can potentially be a tool for the accurate diagnosis of PDAC, and this optical biomarker (Feature-score) may help clinicians make more approximate treatment decisions.


Assuntos
Carcinoma Ductal Pancreático , Colágeno , Neoplasias Pancreáticas , Humanos , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/patologia , Carcinoma Ductal Pancreático/mortalidade , Carcinoma Ductal Pancreático/metabolismo , Prognóstico , Feminino , Masculino , Colágeno/metabolismo , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/diagnóstico , Pessoa de Meia-Idade , Idoso , Microscopia de Geração do Segundo Harmônico/métodos , Biomarcadores Tumorais/metabolismo , Biomarcadores Tumorais/análise , Estimativa de Kaplan-Meier , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Adulto , Microambiente Tumoral
5.
Exp Eye Res ; 244: 109941, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38782177

RESUMO

Refractive errors remain a global health concern, as a large proportion of the world's population is myopic. Current ablative approaches are costly, not without risks, and not all patients are candidates for these procedures. Electromechanical reshaping (EMR) has been explored as a viable cost-effective modality to directly shape tissues, including cartilage. In this study, stromal collagen structure and fibril orientation was examined before and after EMR with second-harmonic generation microscopy (SHG), a nonlinear multiphoton imaging method that has previously been used to study native corneal collagen with high spatial resolution. EMR, using a milled metal contact lens and potentiostat, was performed on the corneas of five extracted rabbit globes. SHG was performed using a confocal microscopy system and all images underwent collagen fibril orientation analysis. The collagen SHG signal in controls is uniform and is similarly seen in samples treated with pulsed potential, while continuous EMR specimens have reduced, nonhomogeneous signal. Collagen fibril orientation in native tissue demonstrates a broad distribution with suggestion of another peak evolving, while with EMR treated eyes a bimodal characteristic becomes readily evident. Pulsed EMR may be a means to correct refractive errors, as when comparing its SHG signal to negative control, preservation of collagen structures with little to no damage is observed. From collagen fiber orientation analysis, it can be inferred that simple DC application alters the structure of collagen. Future studies will involve histological assessment of these layers and multi-modal imaging analysis of dosimetry.


Assuntos
Colágeno , Microscopia Confocal , Microscopia de Geração do Segundo Harmônico , Animais , Coelhos , Microscopia de Geração do Segundo Harmônico/métodos , Colágeno/metabolismo , Substância Própria/metabolismo , Córnea
6.
Nano Lett ; 23(17): 7975-7982, 2023 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-37642385

RESUMO

Second-harmonic generation (SHG) is a noninvasive imaging technique that enables the exploration of physiological structures without the use of an exogenous label. However, traditional SHG imaging is limited by optical diffraction, which restricts the spatial resolution. To break this limitation, we developed a novel approach called multifocal structured illumination microscopy-SHG (MSIM-SHG). By combination of SHG with MSIM, SHG-based super-resolution imaging of material molecules can be achieved, and this SHG super-resolution imaging has a wide range of applications for biological tissues and cells. MSIM-SHG achieved a lateral full width at half-maximum (fwhm) of 147 ± 13 nm and an axial fwhm of 493 ± 47 nm by imaging zinc oxide (ZnO) particles. Furthermore, MSIM-SHG was utilized to quantify collagen fiber alignment in various tissues such as the ovary, muscle, heart, kidney, and cartilage, demonstrating its feasibility for identifying collagen characteristics. MSIM-SHG has potential as a powerful tool for clinical diagnosis and biological research.


Assuntos
Microscopia , Microscopia de Geração do Segundo Harmônico , Feminino , Humanos , Iluminação , Matriz Extracelular , Coração
7.
Biophys J ; 122(4): 624-631, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36659849

RESUMO

In biology, release of Ca2+ ions in the cytosol is essential to trigger or control many cell functions. Calcium signaling acutely depends on lipid membrane permeability to Ca2+. For proper understanding of membrane permeability to Ca2+, both membrane hydration and the structure of the hydrophobic core must be taken into account. Here, we vary the hydrophobic core of bilayer membranes and observe different types of behavior in high-throughput wide-field second harmonic imaging. Ca2+ translocation is observed through mono-unsaturated (DOPC:DOPA) membranes, reduced upon the addition of cholesterol, and completely inhibited for branched (DPhPC:DPhPA) and poly-unsaturated (SLPC:SLPA) lipid membranes. We propose, using molecular dynamics simulations, that ion transport occurs through ion-induced transient pores, which requires nonequilibrium membrane restructuring. This results in different rates at different locations and suggests that the hydrophobic structure of lipids plays a much more sophisticated regulating role than previously thought.


Assuntos
Bicamadas Lipídicas , Microscopia de Geração do Segundo Harmônico , Bicamadas Lipídicas/química , Microscopia , Íons , Colesterol/química , Simulação de Dinâmica Molecular
8.
Opt Lett ; 48(12): 3199-3202, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37319061

RESUMO

We report a systematic investigation into the processes behind a near hundred-fold enhanced second harmonic wave generated from a laser-induced air plasma, by examining the temporal dynamics of the frequency conversion processes, and the polarization of the emitted second harmonic beam. Contrary to typical nonlinear optical processes, the enhanced second harmonic generation efficiency is only observed within a sub-picosecond time window and found to be nearly constant across fundamental pulse durations spanning from 0.1 ps to over 2 ps. We further demonstrate that with the adopted orthogonal pump-probe configuration, the polarization of the second harmonic field exhibits a complex dependence on the polarization of both input fundamental beams, contrasting with most of the previous experiments with a single-beam geometry.


Assuntos
Microscopia de Geração do Segundo Harmônico , Frequência Cardíaca , Lasers
9.
Exp Dermatol ; 32(4): 392-402, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36409162

RESUMO

Basal cell carcinoma (BCC) is the most common skin cancer, and its incidence is rising. Millions of benign biopsies are performed annually for BCC diagnosis, increasing morbidity, and healthcare costs. Non-invasive in vivo technologies such as multiphoton microscopy (MPM) can aid in diagnosing BCC, reducing the need for biopsies. Furthermore, the second harmonic generation (SHG) signal generated from MPM can classify and prognosticate cancers based on extracellular matrix changes, especially collagen type I. We explored the potential of MPM to differentiate collagen changes associated with different BCC subtypes compared to normal skin structures and benign lesions. Quantitative analysis such as frequency band energy analysis in Fourier domain, CurveAlign and CT-FIRE fibre analysis was performed on SHG images from 52 BCC and 12 benign lesions samples. Our results showed that collagen distribution is more aligned surrounding BCCs nests compared to the skin's normal structures (p < 0.001) and benign lesions (p < 0.001). Also, collagen was orientated more parallelly surrounding indolent BCC subtypes (superficial and nodular) versus those with more aggressive behaviour (infiltrative BCC) (p = 0.021). In conclusion, SHG signal from type I collagen can aid not only in the diagnosis of BCC but could be useful for prognosticating these tumors. Our initial results are limited to a small number of samples, requiring large-scale studies to validate them. These findings represent the groundwork for future in vivo MPM for diagnosis and prognosis of BCC.


Assuntos
Carcinoma Basocelular , Microscopia de Geração do Segundo Harmônico , Neoplasias Cutâneas , Humanos , Carcinoma Basocelular/patologia , Neoplasias Cutâneas/patologia , Colágeno , Colágeno Tipo I , Dermoscopia , Microscopia de Fluorescência por Excitação Multifotônica/métodos
10.
Pediatr Radiol ; 53(1): 34-45, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35906430

RESUMO

BACKGROUND: Preclinical animal as well as small exploratory ex vivo and in vivo human studies have suggested that bowel wall shear wave speed (SWS) measurements may be a noninvasive biomarker of intestinal damage. OBJECTIVE: To evaluate the relationships between bowel wall stiffness, measured using ultrasound shear wave elastography (SWE), and intestinal fibrosis and smooth muscle hypertrophy as determined by (1) histology and (2) second harmonic imaging microscopy (SHIM) in surgically resected ileal strictures from pediatric Crohn disease patients. MATERIALS AND METHODS: Nineteen pediatric Crohn disease patients with symptomatic ileal strictures underwent research ultrasound examinations before surgical resection between December 2017 and September 2020. Two-dimensional SWE was performed through the area of the most severe stenosis, with measurements obtained from the bowel wall at the 9:00, 12:00 and 3:00 o'clock locations with 0%, 10% and 20% abdominal strain. Overall right lower quadrant stiffness also was documented. Median bowel wall and overall right lower quadrant SWS measurements were correlated with bowel wall histological scores of inflammation, fibrosis and smooth muscle proliferation as well as SHIM collagen signal. RESULTS: Diagnostic ultrasound SWE imaging was obtained from 18 participants. The median age was 16.8 years. There were negative correlations between histological mucosal active inflammation and both bowel wall SWS with 10% abdominal strain (r=-0.50, P = 0.04) and overall right lower quadrant SWS with 20% abdominal strain (r=-0.69, P = 0.002). There were positive correlations between histological muscularis propria inner layer smooth muscle hypertrophy and both median bowel wall SWS with 10% abdominal strain (r = 0.72, P = 0.002) and overall right lower quadrant SWS with 20% abdominal strain (r = 0.71, P = 0.002). There were no associations between ultrasound stiffness metrics and bowel wall SHIM collagen measurements. CONCLUSION: Bowel wall and overall right lower quadrant ultrasound stiffness measurements correlate with mucosal active inflammation and muscularis propria smooth muscle hypertrophy in pediatric stricturing ileal Crohn disease, but not with intestinal fibrosis.


Assuntos
Doença de Crohn , Técnicas de Imagem por Elasticidade , Microscopia de Geração do Segundo Harmônico , Humanos , Criança , Adolescente , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Constrição Patológica , Técnicas de Imagem por Elasticidade/métodos , Microscopia , Ultrassonografia , Fibrose , Inflamação , Hipertrofia
11.
Microsc Microanal ; 29(4): 1450-1459, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37488816

RESUMO

Starch is a semi-crystalline macromolecule with the presence of amorphous and crystalline components. The amorphous amylose and crystalline amylopectin regions in starch granules are susceptible to certain physical modifications, such as gamma irradiation. Polarization-resolved second harmonic generation (P-SHG) microscopy in conjunction with SHG-circular dichroism (CD) was used to assess the three-dimensional molecular order and inherent chirality of starch granules and their reaction to different dosages of gamma irradiation. For the first time, the relationship between starch achirality (χ21/χ16 and χ22/χ16) and chirality (χ14/χ16) determining susceptibility tensor ratios has been elucidated. The results showed that changes in the structure and orientation of long-chain amylopectin were supported by the decrease in the SHG anisotropy factor and the χ22/χ16 ratio. Furthermore, SHG-CD illustrated the molecular tilt angle by revealing the arrangement of amylopectin molecules pointing either upward or downward owing to molecular polarity.


Assuntos
Amilopectina , Microscopia de Geração do Segundo Harmônico , Amido
12.
J Hand Surg Am ; 48(11): 1170.e1-1170.e7, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36357225

RESUMO

PURPOSE: Nerves that are functionally injured but appear macroscopically intact pose the biggest clinical dilemma. Second Harmonic Generation (SHG) Microscopy may provide a real-time assessment of nerve damage, with the ultimate goal of allowing surgeons to accurately quantify the degree of nerve damage present. The aim of this study was to demonstrate the utility of SHG microscopy to detect nerve damage in vivo in an animal model. METHODS: Ten Sprague-Dawley rats were anesthetized and prepared for surgery. After surgical exposure and using a custom-made stretch applicator, the right median nerves were stretched by 20%, corresponding to a high strain injury, and held for 5 minutes. The left median nerve served as a sham control (SC), only being placed in the applicator for 5 minutes with no stretch. A nerve stimulator was used to assess the amount of stimulation required to induce a flicker and contraction of the paw. Nerves were then imaged using a multiphoton laser scanning microscope. RESULTS: Immediately after injury (day 0), SHG images of SC median nerves exhibited parallel collagen fibers with linear, organized alignment. In comparison with SC nerves, high strain nerves demonstrated artifacts indicative of nerve damage consisting of wavy, undulating fibers with crossing fibers and tears, as well as a decrease in the linear organization, which correlated with an increase in the mean stimulation required to induce a flicker and contraction of the paw. CONCLUSIONS: Second Harmonic Generation microscopy may provide the ability to detect an acute neural stretch injury in the rat median nerve. Epineurial collagen disorganization correlated with the stimulation required for nerve function. CLINICAL RELEVANCE: In the future, SHG may provide the ability to visualize nerve damage intraoperatively, allowing for better clinical decision-making. However, this is currently a research tool and requires further validation before translating to the clinical setting.


Assuntos
Nervo Mediano , Microscopia de Geração do Segundo Harmônico , Ratos , Animais , Ratos Sprague-Dawley , Colágeno , Nervos Periféricos
13.
Nano Lett ; 22(22): 8860-8866, 2022 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-36346747

RESUMO

Chiral nonlinear metasurfaces could natively synergize nonlinear wavefront manipulation and circular dichroism, offering enhanced capacity for multifunctional and multiplexed nonlinear metasurfaces. However, it is still quite challenging to simultaneously enable strong chiral response, precise wavefront control, high nonlinear conversion efficiency, and independent functions on spins and chirality. Here, we propose and experimentally demonstrate multiplexed third-harmonic (TH) holograms with four channels based on a chiral Au-ZnO hybrid metasurface. Specifically, the left- and right-handed circularly polarized (LCP and RCP) components of the TH holographic images can be designed independently under the excitation of an LCP (or RCP) fundamental beam. In addition, the TH conversion efficiency is measured to be as large as 10-5, which is 8.6 times stronger than that of a bare ZnO film with the same thickness. Thus, our work provides a promising platform for realizing efficient and multifunctional nonlinear nanodevices.


Assuntos
Microscopia de Geração do Segundo Harmônico , Óxido de Zinco , Dicroísmo Circular
14.
Nano Lett ; 22(2): 846-852, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35023753

RESUMO

Structural engineering permits the introduction of chirality into organic-inorganic hybrid metal halides (HMHs), which creates a promising and exclusive material for applications in various optoelectronics. However, the optical activity regulation of chiral HMHs remains largely unexplored. In this work, we have synthesized two pairs of lead-free chiral HMHs with a zero-dimensional tetrahedral arrangement, i.e., (R- and S-1-(1-naphthyl)ethylammonium)2CuCl4 and (R- and S-1-(2-naphthyl)ethylammonium)2CuCl4. The magnitude of optical activity in these HMHs can be efficiently modulated as a result of the different magnetic transition dipole moments. Furthermore, these HMHs exhibited effective second-harmonic generation (SHG) and distinct SHG-circular dichroism (CD), with (R-1-(1-naphthyl)ethylammonium)2CuCl4 having an anisotropy factor (gSHG-CD) of up to 0.41. This work not only provides insights into regulating the optical activity and anisotropic SHG effect of lead-free chiral HMHs but also confirms the feasibility of SHG-CD spectroscopy as a promising tool for characterizing the intrinsic optical activity of chiral materials.


Assuntos
Microscopia de Geração do Segundo Harmônico , Anisotropia , Dicroísmo Circular , Cobre , Rotação Ocular , Microscopia de Geração do Segundo Harmônico/métodos
15.
Nano Lett ; 22(23): 9652-9657, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36445198

RESUMO

Metasurfaces have emerged as a fascinating framework for nonlinear optics, which have advantages of a compact footprint and unprecedented flexibility in manipulating light. But their nonlinear responses are generally limited by the short interaction lengths with light. Therefore, further enhancement is highly desired for building high-efficiency nonlinear devices. Here, we experimentally demonstrate a record high second harmonic generation (SHG) efficiency of 2.0 × 10-4 using lithium niobate (LN) membrane metasurfaces. Benefiting from the large refractive index contrast in the vertical direction and high fabrication quality, distinct spectral resonances and tight field confinements in the LN layer were achieved. Strong SHG peaks resulting from pump resonances of the metasurfaces were observed. Our nonlinear efficiency is more than 2 orders of magnitude larger than previously reported LN metasurfaces. The results inspire a way to improve the efficiency of nonlinear metasurfaces for ultracompact nonlinear light sources in applications of nonlinear holography, Li-Fi, beam shaping, etc.


Assuntos
Microscopia de Geração do Segundo Harmônico , Membranas , Lítio , Óxidos
16.
Int J Mol Sci ; 24(4)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36835613

RESUMO

The characterization and evaluation of skin tissue structures are crucial for dermatological applications. Recently, Mueller matrix polarimetry and second harmonic generation microscopy have been widely used in skin tissue imaging due to their unique advantages. However, the features of layered skin tissue structures are too complicated to use a single imaging modality for achieving a comprehensive evaluation. In this study, we propose a dual-modality imaging method combining Mueller matrix polarimetry and second harmonic generation microscopy for quantitative characterization of skin tissue structures. It is demonstrated that the dual-modality method can well divide the mouse tail skin tissue specimens' images into three layers of stratum corneum, epidermis, and dermis. Then, to quantitatively analyze the structural features of different skin layers, the gray level co-occurrence matrix is adopted to provide various evaluating parameters after the image segmentations. Finally, to quantitatively measure the structural differences between damaged and normal skin areas, an index named Q-Health is defined based on cosine similarity and the gray-level co-occurrence matrix parameters of imaging results. The experiments confirm the effectiveness of the dual-modality imaging parameters for skin tissue structure discrimination and assessment. It shows the potential of the proposed method for dermatological practices and lays the foundation for further, in-depth evaluation of the health status of human skin.


Assuntos
Colágeno , Microscopia de Geração do Segundo Harmônico , Humanos , Animais , Camundongos , Colágeno/química , Pele , Diagnóstico por Imagem , Análise Espectral
17.
Molecules ; 28(11)2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37298807

RESUMO

Subtle variations in the structure and composition of lipid membranes can have a profound impact on their transport of functional molecules and relevant cell functions. Here, we present a comparison of the permeability of bilayers composed of three lipids: cardiolipin, DOPG (1,2-dioleoyl-sn-glycero-3-phospho-(1'-rac-glycerol), and POPG (1-palmitoyl-2-oleoyl-sn-glycero-3-phospho-(1'-rac-glycerol)). The adsorption and cross-membrane transport of a charged molecule, D289 (4-(4-diethylaminostyry)-1-methyl-pyridinium iodide), on vesicles composed of the three lipids were monitored by second harmonic generation (SHG) scattering from the vesicle surface. It is revealed that structural mismatching between the saturated and unsaturated alkane chains in POPG leads to relatively loose packing structure in the lipid bilayers, thus providing better permeability compared to unsaturated lipid bilayers (DOPG). This mismatching also weakens the efficiency of cholesterol in rigidifying the lipid bilayers. It is also revealed that the bilayer structure is somewhat disturbed by the surface curvature in small unilamellar vesicles (SUVs) composed of POPG and the conical structured cardiolipin. Such subtle information on the relationship between the lipid structure and the molecular transport capability of the bilayers may provide clues for drug development and other medical and biological studies.


Assuntos
Bicamadas Lipídicas , Microscopia de Geração do Segundo Harmônico , Bicamadas Lipídicas/química , Cardiolipinas , Glicerol , Fosfatidilcolinas/química
18.
Anal Chem ; 94(43): 15027-15032, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36269876

RESUMO

The binding interaction between the DNA repair enzyme apurinic/apyrimidinic endonuclease-1 (APE1) with promoter G-quadruplex (G4) folds bearing an abasic site (AP) can serve as a gene regulatory switch during oxidative stress. Prior fluorescence-based analysis in solution suggested APE1 binds the VEGF promoter G4 but whether this interaction was specific or not remained an open question. Second harmonic generation (SHG) was used in this work to measure the noncanonical DNA-protein binding interaction in a label-free assay with high sensitivity to demonstrate the interaction is ordered and specific. The binding of APE1 to the VEGF promoter G4 with AP sites modeled by a tetrahydrofuran analogue produced dissociation constants of ∼100 nM that differed from duplex and single-stranded DNA control studies. The SHG measurements confirmed APE1 binds the VEGF G4 folds in a specific manner resolving a remaining question regarding how this endonuclease with gene regulatory features engages G4 folds. The studies demonstrate the power of SHG to interrogate noncanonical DNA-protein interactions providing a foundational example for the use of this analytical method in future biochemical analyses.


Assuntos
Quadruplex G , Microscopia de Geração do Segundo Harmônico , Endonucleases/metabolismo , Fator A de Crescimento do Endotélio Vascular/genética , DNA Liase (Sítios Apurínicos ou Apirimidínicos)/metabolismo , DNA/genética , Reparo do DNA
19.
Small ; 18(18): e2200205, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35355419

RESUMO

Optical interrogation of cellular electrical activity has proven itself essential for understanding cellular function and communication in complex networks. Voltage-sensitive dyes are important tools for assessing excitability but these highly lipophilic sensors may affect cellular function. Label-free techniques offer a major advantage as they eliminate the need for these external probes. In this work, it is shown that endogenous second-harmonic generation (SHG) from live cells is highly sensitive to changes in transmembrane potential (TMP). Simultaneous electrophysiological control of a living human embryonic kidney (HEK293T) cell, through a whole-cell voltage-clamp reveals a linear relation between the SHG intensity and membrane voltage. The results suggest that due to the high ionic strengths and fast optical response of biofluids, membrane hydration is not the main contributor to the observed field sensitivity. A conceptual framework is further provided that indicates that the SHG voltage sensitivity reflects the electric field within the biological asymmetric lipid bilayer owing to a nonzero χeff(2) tensor. Changing the TMP without surface modifications such as electrolyte screening offers high optical sensitivity to membrane voltage (≈40% per 100 mV), indicating the power of SHG for label-free read-out. These results hold promise for the design of a non-invasive label-free read-out tool for electrogenic cells.


Assuntos
Microscopia de Geração do Segundo Harmônico , Corantes , Células HEK293 , Humanos , Potenciais da Membrana
20.
Am J Pathol ; 191(12): 2184-2194, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34560063

RESUMO

Collagen XIV is poorly characterized in the body, and the current knowledge of its function in the cornea is limited. The aim of the current study was to elucidate the role(s) of collagen XIV in regulating corneal stromal structure and function. Analysis of collagen XIV expression, temporal and spatial, was performed at different postnatal days (Ps) in wild-type C57BL/6 mouse corneal stromas and after injury. Conventional collagen XIV null mice were used to inquire the roles that collagen XIV plays in fibrillogenesis, fibril packing, and tissue mechanics. Fibril assembly and packing as well as stromal organization were evaluated using transmission electron microscopy and second harmonic generation microscopy. Atomic force microscopy was used to assess stromal stiffness. Col14a1 mRNA expression was present at P4 to P10 and decreased at P30. No immunoreactivity was noted at P150. Abnormal collagen fibril assembly with a shift toward larger-diameter fibrils and increased interfibrillar spacing in the absence of collagen XIV was found. Second harmonic generation microscopy showed impaired fibrillogenesis in the collagen XIV null stroma. Mechanical testing suggested that collagen XIV confers stiffness to stromal tissue. Expression of collagen XIV is up-regulated following injury. This study indicates that collagen XIV plays a regulatory role in corneal development and in the function of the adult cornea. The expression of collagen XIV is recapitulated during wound healing.


Assuntos
Colágeno/fisiologia , Substância Própria/fisiologia , Substância Própria/ultraestrutura , Envelhecimento/fisiologia , Animais , Colágeno/genética , Córnea/diagnóstico por imagem , Córnea/metabolismo , Córnea/ultraestrutura , Paquimetria Corneana , Substância Própria/diagnóstico por imagem , Substância Própria/patologia , Matriz Extracelular/metabolismo , Matriz Extracelular/patologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Eletrônica de Transmissão , Microscopia de Geração do Segundo Harmônico , Tomografia de Coerência Óptica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa