Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.408
Filtrar
Mais filtros

Eixos temáticos
Intervalo de ano de publicação
1.
Eur Heart J ; 45(3): 198-210, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-37874971

RESUMO

BACKGROUND AND AIMS: Transcatheter pulmonary valve implantation (TPVI) is indicated to treat right-ventricular outflow tract (RVOT) dysfunction related to congenital heart disease (CHD). Outcomes of TPVI with the SAPIEN 3 valve that are insufficiently documented were investigated in the EUROPULMS3 registry of SAPIEN 3-TPVI. METHODS: Patient-related, procedural, and follow-up outcome data were retrospectively assessed in this observational cohort from 35 centres in 15 countries. RESULTS: Data for 840 consecutive patients treated in 2014-2021 at a median age of 29.2 (19.0-41.6) years were obtained. The most common diagnosis was conotruncal defect (70.5%), with a native or patched RVOT in 50.7% of all patients. Valve sizes were 20, 23, 26, and 29 mm in 0.4%, 25.5%, 32.1%, and 42.0% of patients, respectively. Valve implantation was successful in 98.5% [95% confidence interval (CI), 97.4%-99.2%] of patients. Median follow-up was 20.3 (7.1-38.4) months. Eight patients experienced infective endocarditis; 11 required pulmonary valve replacement, with a lower incidence for larger valves (P = .009), and four experienced pulmonary valve thrombosis, including one who died and three who recovered with anticoagulation. Cumulative incidences (95%CI) 1, 3, and 6 years after TPVI were as follows: infective endocarditis, 0.5% (0.0%-1.0%), 0.9% (0.2%-1.6%), and 3.8% (0.0%-8.4%); pulmonary valve replacement, 0.4% (0.0%-0.8%), 1.3% (0.2%-2.4%), and 8.0% (1.2%-14.8%); and pulmonary valve thrombosis, 0.4% (0.0%-0.9%), 0.7% (0.0%-1.3%), and 0.7% (0.0%-1.3%), respectively. CONCLUSIONS: Outcomes of SAPIEN 3 TPVI were favourable in patients with CHD, half of whom had native or patched RVOTs.


Assuntos
Endocardite Bacteriana , Endocardite , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Trombose , Adulto , Humanos , Cateterismo Cardíaco/efeitos adversos , Endocardite/epidemiologia , Endocardite Bacteriana/complicações , Cardiopatias Congênitas/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/epidemiologia , Insuficiência da Valva Pulmonar/cirurgia , Sistema de Registros , Estudos Retrospectivos , Trombose/etiologia , Resultado do Tratamento
2.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
3.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-37552784

RESUMO

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Assuntos
Estenose da Valva Aórtica , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Fatores de Risco
4.
Lancet ; 402(10412): 1529-1540, 2023 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-37660719

RESUMO

BACKGROUND: With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry. METHODS: This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching. FINDINGS: Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42·3%] of 1320 female, 761 [57·7%] male; mean predicted surgical risk of 30-day mortality 8·1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0·3%] of 1320; intraprocedural death: eight [0·6%] of 1320; conversion to open heart surgery: six [0·5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4·7% vs 4·0%, p=0·36) or 1 year (17·5% vs 19·0%, p=0·57), and stroke at 30 days (2·0% vs 1·9%, p=0·84) or 1 year (3·2% vs 3·5%, p=0·80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0·0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1·8% vs 3·3%, p=0·18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable). INTERPRETATION: Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Fatores de Risco , Desenho de Prótese
5.
BMC Med ; 22(1): 61, 2024 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331876

RESUMO

BACKGROUND: Infective endocarditis (IE) following cardiac valve surgery is associated with high morbidity and mortality. Data on the impact of iatrogenic healthcare exposures on this risk are sparse. This study aimed to investigate risk factors including healthcare exposures for post open-heart cardiac valve surgery endocarditis (PVE). METHODS: In this population-linkage cohort study, 23,720 patients who had their first cardiac valve surgery between 2001 and 2017 were identified from an Australian state-wide hospital-admission database and followed-up to 31 December 2018. Risk factors for PVE were identified from multivariable Cox regression analysis and verified using a case-crossover design sensitivity analysis. RESULTS: In 23,720 study participants (median age 73, 63% male), the cumulative incidence of PVE 15 years after cardiac valve surgery was 7.8% (95% CI 7.3-8.3%). Thirty-seven percent of PVE was healthcare-associated, which included red cell transfusions (16% of healthcare exposures) and coronary angiograms (7%). The risk of PVE was elevated for 90 days after red cell transfusion (HR = 3.4, 95% CI 2.1-5.4), coronary angiogram (HR = 4.0, 95% CI 2.3-7.0), and healthcare exposures in general (HR = 4.0, 95% CI 3.3-4.8) (all p < 0.001). Sensitivity analysis confirmed red cell transfusion (odds ratio [OR] = 3.9, 95% CI 1.8-8.1) and coronary angiogram (OR = 2.6, 95% CI 1.5-4.6) (both p < 0.001) were associated with PVE. Six-month mortality after PVE was 24% and was higher for healthcare-associated PVE than for non-healthcare-associated PVE (HR = 1.3, 95% CI 1.1-1.5, p = 0.002). CONCLUSIONS: The risk of PVE is significantly higher for 90 days after healthcare exposures and associated with high mortality.


Assuntos
Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Masculino , Idoso , Feminino , Estudos de Coortes , Próteses Valvulares Cardíacas/efeitos adversos , Austrália/epidemiologia , Valvas Cardíacas , Endocardite/epidemiologia , Endocardite/etiologia , Infecções Relacionadas à Prótese/cirurgia
6.
Am Heart J ; 269: 158-166, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38163616

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic valve stenosis, but is still associated with relatively high rates of pacemaker implantation and paravalvular regurgitation. Routine preoperative computed tomography (CT) combined with patient-specific computer modelling can predict the interaction between the TAVI device and the patient's unique anatomy, allowing physicians to assess the risk for paravalvular regurgitation and conduction disorders in advance to the procedure. The aim of this trial is to assess potential improvement in the procedural outcome of TAVI by applying CT-based patient-specific computer simulations in patients with suitable anatomy for TAVI. METHODS: The GUIDE-TAVI trial is an international multicenter randomized controlled trial including patients accepted for TAVI by the Heart Team. Patients enrolled in the study will be randomized into 2 arms of each 227 patients. In patients randomized to the use of FEops HEARTGuide (FHG), patient-specific computer simulation with FHG is performed in addition to routine preoperative CT imaging and results of the FHG are available to the operator(s) prior to the scheduled intervention. In patients randomized to no use of FHG, only routine preoperative CT imaging is performed. The primary objective is to evaluate whether the use of FHG will reduce the incidence of mild to severe PVR, according to the Valve Academic Research Consortium 3. Secondary endpoints include the incidence of new conduction disorders requiring permanent pacemaker implantation, the difference between preoperative and final selected valve size, the difference between target and final implantation depth, change of preoperative decision, failure to implant valve, early safety composite endpoint and quality of life. CONCLUSIONS: The GUIDE-TAVI trial is the first multicenter randomized controlled trial to evaluate the value of 3-dimensional computer simulations in addition to standard preprocedural planning in TAVI procedures.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Simulação por Computador , Qualidade de Vida , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X/efeitos adversos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos
7.
Am Heart J ; 273: 21-34, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38570020

RESUMO

BACKGROUND: Optimal first-trimester anticoagulation is still challenging in pregnant women with mechanical heart valves (MHVs) requiring high-dose warfarin. This multicenter prospective study aims to determine the optimal anticoagulation regimens for pregnant patients with MHVs. METHODS: All women were allocated to one of three treatment options during first trimester including lone low-molecular-weight heparin (LMWH), combination of LMWH + 2.5 mg warfarin, and LMWH+4 mg warfarin. Primary maternal outcome included a combination of death, thromboembolism, severe bleeding, and need for treatment of mechanical valve thrombosis (MVT). Any fetal loss was determined as primary fetal outcome. RESULTS: The study included 78 pregnancies in 65 women with MHVs. Primary maternal outcome rate was 44%, 12.5%, 3.5%, respectively. The rates of primary maternal outcome (44 vs 3.5%, P < .001), obstructive MVT (16 vs 0%, P = .04), MVT requiring treatment (28 vs 0%, P = .003), and cerebral embolism (24 vs 3.4%, P = .041) were found to be significantly higher in lone LMWH group compared to LMWH + 4 mg warfarin group. Moreover, the rates of primary maternal outcome (12.5 vs 44%, P = .015) and treatment for MHV thrombus (4.2 vs 28%, P = .049) were significantly lower in LMWH + 2.5 mg warfarin group compared to lone LMWH group. The incidences of fetal loss were 8 (32%) in the lone LMWH group, 8 (33.3%) in LMWH + 2.5 mg warfarin group, and 11 (37.9%) in LMWH + 4 mg warfarin group (P = .890 for 3-group).Warfarin related-embryopathy was not observed in any case. CONCLUSIONS: The combined anticoagulation strategy of LMWH plus low-dose warfarin during the first trimester of pregnancy may result in less maternal complications with comparable fetal outcomes in patients with MHVs. CONDENSED ABSTRACT: Low-molecular-weight heparin (LMWH) is thought to be safer for the fetus, however it is suspected to be less protective for the mother. To solve this dilemma, the authors suggested a novel anticoagulation strategy in pregnant women with prosthetic valves. Seventy-eight pregnancies of 65 women (median age 32 [27-35] years) were included in the study. A combination of LMWH and a reduced dose warfarin were associated with low rates of thrombus-related complications in pregnant patients with mechanical heart valves.


Assuntos
Anticoagulantes , Próteses Valvulares Cardíacas , Heparina de Baixo Peso Molecular , Complicações Cardiovasculares na Gravidez , Varfarina , Humanos , Feminino , Gravidez , Anticoagulantes/administração & dosagem , Adulto , Varfarina/administração & dosagem , Varfarina/efeitos adversos , Complicações Cardiovasculares na Gravidez/tratamento farmacológico , Heparina de Baixo Peso Molecular/administração & dosagem , Heparina de Baixo Peso Molecular/uso terapêutico , Heparina de Baixo Peso Molecular/efeitos adversos , Estudos Prospectivos , Próteses Valvulares Cardíacas/efeitos adversos , Quimioterapia Combinada , Resultado da Gravidez , Primeiro Trimestre da Gravidez , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/epidemiologia , Trombose/prevenção & controle , Trombose/etiologia
8.
Heart Fail Rev ; 29(1): 219-226, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37851119

RESUMO

Tricuspid regurgitation (TR) is the most common valvular pathology after heart transplantation (HTx) and endomyocardial biopsy (EMB) remains responsible for the majority of cases due to the high probability of structural valve damage. The aim of the present review was to describe the results of surgical management of severe tricuspid regurgitation through tricuspid valve replacement (TVR) after a previous HTx. A systematic review was conducted by searching Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane databases until June 2023 for publications reporting patients undergoing TVR surgery after a previous HTx. If no right heart valve surgery was undertaken, or a heterotopic heart transplant was performed, or if the concomitant procedure was performed during the transplant itself, the paper was excluded. Twenty articles met our inclusion criteria out of 1532 potentially eligible studies, with a total of 300 patients. Mean age was 55.1 ± 9.6 years, and 85.1% were male. The mean number of EMB per patient was 31.1 ± 5.5 with a mean time between HTx and TVR of 7.64 ± 3.31 years. Bioprostheses were used in 83.3% of cases and 75.0% of patients with a bioprosthesis were reported as alive at last follow-up. Tricuspid valve repair is a valuable option, but these patients will be susceptible to recurrent TR after EMB. TVR with a bioprosthesis may provide the optimal solution for this subset of patients, as EMB is not feasible with a mechanical valve.


Assuntos
Transplante de Coração , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Valva Tricúspide/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Próteses Valvulares Cardíacas/efeitos adversos , Transplante de Coração/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
9.
Curr Opin Cardiol ; 39(5): 457-464, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38899782

RESUMO

PURPOSE OF REVIEW: Subclinical leaflet thrombosis (SLT) is often an incidental finding characterized by a thin layer of thrombus involving one, two or three leaflets, with typical appearance on multi-detector computed tomography (MDCT) of hypo-attenuating defect at the aortic side of the leaflet, also called hypo-attenuating leaflet thickening (HALT). SLT may occur following both transcatheter aortic replacement (TAVR) or biological surgical aortic valve replacement (SAVR). The aim of this review is to present an overview of the current state of knowledge on the incidence, diagnosis, clinical impact, and management of SLT following TAVR or SAVR. RECENT FINDINGS: SLT occurs in 10-20% of patients following TAVR and is somewhat more frequent than following SAVR (5-15%). SLT may regress spontaneously without treatment in about 50% of the cases but may also progress to clinically significant valve thrombosis in some cases. Oral anticoagulation with vitamin K antagonist is reasonable if SLT is detected by echocardiography and/or MDCT during follow-up and is generally efficient to reverse SLT. SLT is associated with mild increase in the risk of stroke but has no impact on survival. SLT has been linked with accelerated structural valve deterioration and may thus impact valve durability and long-term outcomes. SUMMARY: SLT is often an incidental finding on echocardiography or MDCT that occurs in 10-20% of patients following TAVR or 5-15% following biological SAVR and is associated with a mild increase in the risk of thrombo-embolic event with no significant impact on mortality but may be associated with reduced valve durability.


Assuntos
Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Trombose/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Complicações Pós-Operatórias/etiologia , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
10.
Catheter Cardiovasc Interv ; 103(1): 238-242, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37971094

RESUMO

A 75-year-old female was found to have mechanical mitral valve thrombosis complicated by severe mitral stenosis, pulmonary edema, and right heart failure. She was at prohibitive risk for surgical intervention. She did not tolerate thrombolysis due to bleeding. We performed percutaneous intervention with cerebral protection with subsequent restoration of mechanical mitral valve function, resolution of the mitral valve stenosis, and no neurologic complications.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Trombose , Feminino , Humanos , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/terapia , Próteses Valvulares Cardíacas/efeitos adversos
11.
Catheter Cardiovasc Interv ; 103(1): 153-159, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38071423

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has become an alternative for high-risk patients with severe mitral regurgitation (MR). The aim of this study was to evaluate the safety and feasibility of the Mi-thos TMVR system (NewMed Medical) for high-risk patients with severe MR. METHODS: This was a prospective, two-center, single-arm early feasibility study. Baseline characteristics, procedural data and 30-day follow-up outcomes were collected and analyzed. The primary endpoint was intraoperative success rate of device implantation. The second endpoints were all-cause mortality and major post-procedural complications. Echocardiographic data were evaluated by an independent core laboratory. Clinical events were adjudicated by a clinical events committee. RESULTS: Ten high-risk patients with severe MR were enrolled at two sites from August 2021 to November 2022. The median age was 70.5 years, and 60% of patients were female. The median Society of Thoracic Surgeons Predicted Risk of Mortality was 9.5%. The Mi-thos TMVR system was successfully implanted via transapical access in all patients. There was no pericedural mortality or major postpericedural complications during the 30-day follow-up. All implanted prosthetic valves had no or trace valvular or paravalvular MR, and the median mitral valve gradient at 30 days was 2.0 mmHg (IQR: 2.0-3.0 mmHg). There was one mild left ventricular outflow tract obstruction. CONCLUSIONS: The favorable short-term outcomes of the Mi-thos TMVR system demonstrated that it might be a feasible and safe therapeutic alternative for high-risk patients with severe MR. Nevertheless, further evaluation of the Mi-thos TMVR system is warranted.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Prospectivos , Cateterismo Cardíaco , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 103(2): 359-366, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38054354

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) with the self-expandable Venus P-valve system is a promising treatment for patients with pulmonary regurgitation (PR) and a native right ventricular outflow tract (RVOT). However, limited data is available regarding its midterm outcomes. This study assessed the midterm clinical and echocardiographic outcomes following Venus P-valve implantation. METHODS: From 2013 to 2018, 55 patients with moderate or severe PR after surgical RVOT repair with a transannular or RVOT patch were consecutively enrolled from six hospitals in China. Five-year clinical and echocardiographic outcomes were collected and evaluated. The primary endpoint was a freedom from all-cause mortality and reintervention. RESULTS: At 5 years, the primary endpoint was met for 96% of patients, corresponding to a freedom from all-cause mortality of 96% (95% confidence interval [CI]: 86%-99%) and freedom from reintervention of 98% (95% CI: 87%-100%). Endocarditis was reported in five patients (four patients within 1 year and one patient at 5 years) following PPVI. Transpulmonary gradient and stent orifice diameter remained stable compared to at discharge (p>0.05). No paravalvular leak was reported while only 1 patient gradually increased to moderate PR during follow-up. Significant improvement of RV diameter and LVEF (p<0.001) sustained over the 5-year follow-up, in consistent with remarked improved New York Heart Association(NYHA) functional class (p<0.001). CONCLUSION: The 5-year results of the China VenusP Study demonstrated the midterm benefits of Venus P-valve implantation in the management of patients with severe PR with an enlarged native RVOT by providing sustained symptomatic and hemodynamic improvement.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Humanos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
13.
Eur J Clin Microbiol Infect Dis ; 43(1): 95-104, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37964043

RESUMO

PURPOSE: The duration of antibiotic treatment for prosthetic valve endocarditis caused by Streptococcus spp. is largely based on clinical observations and expert opinion rather than empirical studies. Here we assess the impact of a shorter antibiotic duration. OBJECTIVES: To assess the impact of antibiotic treatment duration for streptococcal prosthetic valve endocarditis on 12-month mortality as well as subsequent morbidity resulting in additional cardiac surgical interventions, and rates of relapse and reinfection. METHODS: This retrospective multisite (N= 3) study examines two decades of data on patients with streptococcal prosthetic valve endocarditis receiving either 4 or 6 weeks of antibiotics. Overall mortality, relapse, and reinfection rates were also assessed for the entire available follow-up period. RESULTS: The sample includes 121 patients (median age 72 years, IQR [53; 81]). The majority (74%, 89/121) received a ß-lactam antibiotic combined with aminoglycoside in 74% (89/121, median bi-therapy 5 days [1; 14]). Twenty-eight patients underwent surgery guided by ESC-guidelines (23%). The 12-month mortality rate was not significantly affected by antibiotic duration (4/40, 10% in the 4-week group vs 3/81, 3.7% in the 6-week group, p=0.34) or aminoglycoside usage (p=0.1). Similarly, there were no significant differences between the 2 treatment groups for secondary surgical procedures (7/40 vs 21/81, p=0.42), relapse or reinfection (1/40 vs 2/81 and 2/40 vs 5/81 respectively). CONCLUSIONS: Our study found no increased adverse outcomes associated with a 4-week antibiotic duration compared to the recommended 6-week regimen. Further randomized trials are needed to ascertain the optimal duration of treatment for streptococcal endocarditis.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Idoso , Humanos , Aminoglicosídeos/uso terapêutico , Antibacterianos/uso terapêutico , Duração da Terapia , Endocardite/tratamento farmacológico , Endocardite/etiologia , Endocardite Bacteriana/microbiologia , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Prognóstico , Reinfecção , Estudos Retrospectivos , Streptococcus
14.
Circ J ; 88(4): 549-558, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36709983

RESUMO

BACKGROUND: This study analyzed the safety and performance of the Perceval valve for aortic valve replacement (AVR) in patients at 1 year after undergoing aortic stenosis (AS) treatment, and its effect on significant declines in the platelet count during the immediate postoperative period.Methods and Results: Data were collected retrospectively for the initial 121 patients (median age 77 years; 47.1% females) who underwent Perceval sutureless AVR between May 2019 and July 2022. Implantation was successful in all (100%), with median cross-clamp and CPB times of 59 and 100 min, respectively. Postoperative thrombocytopenia (platelet count <50×103/µL) was noted in 80 (66.1%) patients. Multivariate analysis showed advanced age (>80 years), preoperative low platelet count (<200×103/µL), and a sternotomy approach as significant risk factors for postoperative thrombocytopenia. One (0.8%) patient died within 30 days after the procedure. The 2-year site-reported event rate was 14% (n=17) for all-cause mortality, 0.8% (n=1) for cardiac mortality, 4.1% (n=5) for stroke, and 1.7% (n=2) for endocarditis and valve-related reoperation; there were no instances of paravalvular leakage or structural valve deterioration. CONCLUSIONS: Thrombocytopenia was common after Perceval sutureless AVR, although its impact was not significant. Although Perceval sutureless AVR was found to be a safe and effective option, preoperative assessment of potential bleeding should be performed and the Perceval valve should not be used for patients with a high bleeding risk.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Desenho de Prótese , Bioprótese/efeitos adversos
15.
Circ J ; 88(4): 559-567, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37019644

RESUMO

BACKGROUND: Studies of the influence of smaller body type on the severity of prosthesis-patient mismatch (PPM) after small-sized surgical aortic valve replacement (SAVR) are few, but the issue is particularly relevant for Asian patients.Methods and Results: 695 patients who underwent SAVR with bioprosthetic valves had their hemodynamic valve performance analyzed at 3 months, 1 year, 3 years, and 5 years after operation, and clinical outcomes were assessed. The patients were stratified into 3 valve size groups: 19/21, 23, and 25/27 mm. A smaller valve was associated with higher mean pressure gradients at the 4 time points after operation (P trend <0.05). However, the 3 valve size groups demonstrated no significant differences in the risk of clinical events. At none of the time points did patients with projected PPM show increased mean pressure gradients (P>0.05), whereas patients with measured PPM did (P<0.05). Compared with patients with projected PPM, those with measured PPM demonstrated higher rates of infective endocarditis readmission (adjusted hazard ratio [aHR] 3.31, 95% confidence interval [CI] 1.06-10.39) and a higher risk of composite outcomes (aHR 1.45, 95% CI 0.95-2.22, P=0.087). CONCLUSIONS: Relative to those receiving larger valves, patients receiving small bioprosthetic valves had poorer hemodynamic performance but did not demonstrate differences in clinical events in long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Seguimentos , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Hemodinâmica
16.
Circ J ; 88(5): 652-662, 2024 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-38325847

RESUMO

BACKGROUND: Coronary artery complications (CACs) in patients who undergoing prosthetic pulmonary valve implantation for congenital heart disease can lead to fetal outcomes. However, the incidence of and risk factors for CACs in these patients remain unknown. METHODS AND RESULTS: A retrospective cohort study was conducted on patients who underwent cardiac computed tomography or invasive coronary angiography after prosthetic pulmonary valve implantation at Seoul National University Hospital from June 1986 to May 2021. Among 341 patients, 25 (7.3%) were identified with CACs, and 2 of them died. Among the patients with CACs, congenital coronary anomalies and an interarterial course of the coronary artery were identified in 11 (44%) and 18 (72%) patients, respectively. Interarterial and intramural courses of the coronary artery were associated with a 4.4- and 10.6-fold increased risk of CACs, respectively. Among patients with tetralogy of Fallot and pulmonary atresia, the aortic root was rotated further clockwise in patients with coronary artery compression compared to those without it (mean [±SD] 128.0±19.9° vs. 113.5±23.7°; P=0.024). The cut-off rotation angle of the aorta for predicting the occurrence of coronary artery compression was 133°. CONCLUSIONS: Perioperative coronary artery evaluation and prevention of CACs are required in patients undergoing prosthetic pulmonary valve implantation, particularly in those with coronary artery anomalies or severe clockwise rotation of the aortic root.


Assuntos
Valva Pulmonar , Humanos , Estudos Retrospectivos , Feminino , Masculino , Fatores de Risco , Adulto , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cardiopatias Congênitas/cirurgia , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária , Adolescente , Adulto Jovem , Próteses Valvulares Cardíacas/efeitos adversos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/complicações , Incidência , Criança , Pessoa de Meia-Idade , Tetralogia de Fallot/cirurgia
17.
BMC Infect Dis ; 24(1): 702, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39020296

RESUMO

BACKGROUND: In this prospective, observational study, we aimed to investigate epidemiologic and microbial trends of infective endocarditis in western Norway. METHODS: Clinical and microbiological characteristics of 497 cases of infective endocarditis from 2016 through 2022 were investigated. Categorical data were analysed using Chi-squared tests. Survival data were analysed using multiple Cox regression and reported using hazard ratios. RESULTS: The mean age was 67 years, and 74% were men. The annual incidence rates varied from 10.4 to 14.1 per 100,000 inhabitants per year. Infective endocarditis on native valves was observed in 257 (52%) of the cases, whereas infective endocarditis on prosthetic valves and/or cardiac implantable electronic devices was observed in 240 (48%) of the cases: infection on surgically implanted bioprostheses was observed in 124 (25%) of the patients, infection on transcatheter aortic valve implantation was observed in 47 (10%) patients, and infection on mechanical valves was observed in 34 (7%) cases. Infection related to cardiac implantable electronic devices was observed in a total of 50 (10%) cases. Staphylococcus aureus and viridans streptococci were the most common microbial causes, and isolated in 145 (29%) and 130 (26%) of the cases, respectively. Enterococcal endocarditis showed a rising trend during the study period and constituted 90 (18%) of our total cases of infective endocarditis, and 67%, 47%, and 26% of the cases associated with prosthetic material, transcatheter aortic valve implantation and cardiac implantable electronic devices, respectively. There was no significant difference in 90-day mortality rates between the native valve endocarditis group (12%) and the group with infective endocarditis on prosthetic valves or cardiac implants (14%), p = 0.522. In a model with gender, age, people who inject drugs, microbiology and type of valve affected, only advanced age was significantly associated with fatal outcome within 90 days. CONCLUSIONS: The incidence of infective endocarditis, and particularly enterococcal endocarditis, increased during the study period. Enterococci appeared to have a particular affinity for prosthetic cardiac material. Advanced age was the only independent risk factor for death within 90 days.


Assuntos
Infecções Relacionadas à Prótese , Humanos , Masculino , Noruega/epidemiologia , Feminino , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Incidência , Endocardite/epidemiologia , Endocardite/microbiologia , Endocardite/mortalidade , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/mortalidade , Adulto , Staphylococcus aureus/isolamento & purificação
18.
J Thromb Thrombolysis ; 57(5): 767-774, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38556579

RESUMO

Anticoagulation in patients with mechanical heart valves (MHV) is associated with a risk of major bleeding episodes (MBE). In case of MBE, anticoagulant interruption is advocated. However, there is lack of data regarding the thrombo-embolic events (TE) risk associated with anticoagulant interruption. The main objective of the study was to evaluate the rate and risk factors of 6-months of TEs in patients with MHV experiencing MBE. This observational study was conducted over a 13-year period. Adult patients with a MHV presenting with a MBE were included. The main study endpoint was 6-month TEs, defined by clinical TEs or an echocardiographic documented thrombosis, occurring during an ICU stay or within 6-months. Thromboembolic events were recorded at ICU discharge, and 6 months after discharge. Seventy-nine MBEs were analysed, the rate of TEs at 6-months was 19% CI [11-29%]. The only difference of presentation and management between 6-month TEs and free-TE patients was the time without effective anticoagulation (TWA). The Receiver Operator Characteristic curve identified the value of 122 h of TWA as a cut-off. The multivariate analysis identified early bleeding recurrences (OR 3.62, 95% CI [1.07-12.25], p = 0.039), and TWA longer than 122 h (OR 4.24, 95% CI [1.24-14.5], p = 0.021), as independent risk factors for 6-month TEs. A higher rate of TE was associated with anticoagulation interruption longer than 5 days and early bleeding recurrences. However, the management should still be personalized and discussed for each case given the heterogeneity of causes of MBE and possibilities of haemostatic procedures.


Assuntos
Anticoagulantes , Próteses Valvulares Cardíacas , Hemorragia , Tromboembolia , Humanos , Tromboembolia/etiologia , Tromboembolia/epidemiologia , Masculino , Feminino , Hemorragia/etiologia , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos , Idoso , Fatores de Risco , Anticoagulantes/uso terapêutico , Anticoagulantes/efeitos adversos
19.
Thorac Cardiovasc Surg ; 72(3): 188-196, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36858066

RESUMO

BACKGROUND: Bioprosthetic stentless aortic valves may degenerate over time and will require replacement. This study aimed to evaluate early- and mid-term outcomes after isolated surgical redo aortic valve replacement (redo-SAVR) and transcatheter valve-in-valve implantation (TAVI-VIV) for degenerated stentless Freestyle bioprostheses. METHODS: We reviewed records of 56 patients at a single center. Overall, 37 patients (66.1%) received TAVI-VIV and 19 (33.9%) received redo-SAVR. RESULTS: Thirty-day survival was similar in both groups (100%). One-year survival was comparable between groups (97.3% in TAVI-VIV and 100% in redo-SAVR, p = 1.0). The difference in mid-term survival after adjusting for age and EuroScore II was not significant (p = 0.41). The incidence of pacemaker implantation after TAVI-VIV was higher than after redo-SAVR (19.4% vs. 0%, p = 0.08). CONCLUSION: The 30-day and 1-year survival rates after both procedures were outstanding, irrespective of baseline characteristics. Isolated redo-SAVR should be favored in young patients, as the pacemaker implantation rate is lower. TAVI-VIV for degenerated Freestyle prosthesis can be a method of choice in elderly patients and those with high operative risk.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese , Reoperação/métodos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
20.
Echocardiography ; 41(3): e15783, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38456307

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is gradually becoming an alternative therapy for patients who cannot adapt to surgical treatment or have contraindications. OBJECTIVES: The purpose of this study was to investigate the value of echocardiography in the evaluation of severe AR patients treated with TAVR and to analyze the correlations with postprocedural complications to improve the evaluation and screening of patients. METHODS: We retrospectively analyzed clinical and echocardiographic data of 70 patients with severe AR. Periaortic valve structures were carefully measured by esophageal echocardiography (TEE) and compared with the multilayer slice computed tomography (MSCT) findings. Real-time three-dimensional esophageal echocardiography (RT-3D TEE) was monitored during the operation, and a 30-day postprocedural follow-up was performed. The relationship between postprocedural complications and patients' clinical data or periaortic valve structures was analyzed by multifactorial analysis to identify relevant predictors of complications. RESULTS: The TEE measurements of periaortic valve structures were in good agreement with the MSCT measurements. Among the patients who underwent successful operations, both left atrial (LA) and left ventricular (LV) diameters were reduced, and the left ventricular ejection fraction (LVEF) was improved 30 days after TAVR compared with the preprocedural period (P < .05). Permanent pacemakers were implanted in 15 patients. The presence of preprocedural right bundle branch block (RBBB) (OR: 2.93; 95% CI: 1.18-12.70; P = .01) was an independent factor for permanent pacemaker implantation after TAVR. CONCLUSIONS: Echocardiography plays an extremely important role in TAVR procedures. The presence of preprocedural RBBB can be an independent predictor of postprocedural pacemaker implantation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Função Ventricular Esquerda , Ecocardiografia/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa