Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.911
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Strahlenther Onkol ; 200(1): 71-82, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37380796

RESUMO

PURPOSE: The robustness of surface-guided (SG) deep-inspiration breath-hold (DIBH) radiotherapy (RT) for left breast cancer was evaluated by investigating any potential dosimetric effects due to the residual intrafractional motion allowed by the selected beam gating thresholds. The potential reduction of DIBH benefits in terms of organs at risk (OARs) sparing and target coverage was evaluated for conformational (3DCRT) and intensity-modulated radiation therapy (IMRT) techniques. METHODS: A total of 192 fractions of SGRT DIBH left breast 3DCRT treatment for 12 patients were analyzed. For each fraction, the average of the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift") during beam-on was evaluated and applied to the original plan isocenter. The dose distribution for the treatment beams with the new isocenter point was then calculated and the total plan dose distribution was obtained by summing the estimated perturbed dose for each fraction. Then, for each patient, the original plan and the perturbed one were compared by means of Wilcoxon test for target coverage and OAR dose-volume histogram (DVH) metrics. A global plan quality score was calculated to assess the overall plan robustness against intrafractional motion of both 3DCRT and IMRT techniques. RESULTS: Target coverage and OAR DVH metrics did not show significant variations between the original and the perturbed plan for the IMRT techniques. 3DCRT plans showed significant variations for the left descending coronary artery (LAD) and the humerus only. However, none of the dose metrics exceeded the mandatory dose constraints for any of the analyzed plans. The global plan quality analysis indicated that both 3DCRT and IMRT techniques were affected by the isocenter shifts in the same way and, generally, the residual isocenter shifts more likely tend to worsen the plan in all cases. CONCLUSION: The DIBH technique proved to be robust against residual intrafractional isocenter shifts allowed by the selected SGRT beam-hold thresholds. Small-volume OARs located near high dose gradients showed significant marginal deteriorations in the perturbed plans with the 3DCRT technique only. Global plan quality was mainly influenced by patient anatomy and treatment beam geometry rather than the technique adopted.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Suspensão da Respiração , Radioterapia Conformacional/métodos , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco , Neoplasias Unilaterais da Mama/radioterapia
2.
Strahlenther Onkol ; 200(3): 208-218, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658924

RESUMO

PURPOSE: The purpose of the present prospective study was to evaluate the significance of geriatric conditions measured by a comprehensive geriatric assessment (GA) for the prediction of the risk of high-grade acute radiation-induced toxicity. METHODS: A total of 314 prostate cancer patients (age ≥ 65 years) undergoing definitive radiotherapy at a tertiary academic center were included. Prior to treatment, patients underwent a GA. High-grade toxicity was defined as acute toxicity grade ≥ 2 according to standard RTOG/EORTC criteria. To analyze the predictive value of the GA, univariable and multivariable logistic regression models were applied. RESULTS: A total of 40 patients (12.7%) developed acute toxicity grade ≥ 2; high grade genitourinary was found in 37 patients (11.8%) and rectal toxicity in 8 patients (2.5%), respectively. Multivariable analysis revealed a significant association of comorbidities with overall toxicity grade ≥ 2 (odds ratio [OR] 2.633, 95% confidence interval [CI] 1.260-5.502; p = 0.010) as well as with high-grade genitourinary and rectal toxicity (OR 2.169, 95%CI1.017-4.625; p = 0.045 and OR 7.220, 95%CI 1.227-42.473; p = 0.029, respectively). Furthermore, the Activities of Daily Living score (OR 0.054, 95%CI 0.004-0.651; p = 0.022), social status (OR 0.159, 95%CI 0.028-0.891; p = 0.036), and polypharmacy (OR 4.618, 95%CI 1.045-20.405; p = 0.044) were identified as independent predictors of rectal toxicity grade ≥ 2. CONCLUSION: Geriatric conditions seem to be predictive of the development of high-grade radiation-induced toxicity in prostate cancer patients treated with definitive radiotherapy.


Assuntos
Neoplasias da Próstata , Lesões por Radiação , Radioterapia Conformacional , Masculino , Idoso , Humanos , Dosagem Radioterapêutica , Estudos Prospectivos , Avaliação Geriátrica , Atividades Cotidianas , Neoplasias da Próstata/radioterapia , Lesões por Radiação/diagnóstico , Lesões por Radiação/epidemiologia , Lesões por Radiação/etiologia , Radioterapia Conformacional/efeitos adversos
3.
Acta Oncol ; 63: 511-517, 2024 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-38946286

RESUMO

PURPOSE: In evaluating second primary cancers (SPCs) following External Beam Radiotherapy (EBRT), the role of lifestyle factors is frequently not considered due to data limitations. We investigated the association between smoking, comorbidities, and SPC risks within EBRT-treated patients for localized prostate cancer (PCa). PATIENTS & METHODS: The study included 1,883 PCa survivors aged 50-79, treated between 2006 and 2013, with intensity-modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT). Clinical data were combined with SPC and survival data from the Netherlands Cancer Registry with a 12-month latency period. Standardized Incidence Ratios (SIRs) were calculated comparing the EBRT cohort with the general Dutch population. To explore the effect of patient and treatment characteristics on SPCs we conducted a Cox regression analysis. Lastly, we estimated cumulative incidences of developing solid SPC, pelvis SPC, and non-pelvis SPC using a competing risk analysis. RESULTS: Significantly increased SIRs were observed for all SPC (SIR = 1.21, 95% confidence interval [CI]: 1.08-1.34), pelvis SPC (SIR = 1.46, 95% CI: 1.18-1.78), and non-pelvis SPC (SIR = 1.18, 95% CI [1.04-1.34]). Smoking status was significantly associated with pelvic and non-pelvic SPCs. Charlson comorbidity index (CCI) ≥ 1 (Hazard Ratio [HR] = 1.45, 95% CI: 1.10-1.91), cardiovascular disease (HR = 1.41, 95% CI: 1.05-1.88), and chronic obstructive pulmonary disease (COPD) (HR = 1.91, 95% CI: 1.30-2.79) were significantly associated with non-pelvis SPC. The proportion of active smoking numbers in the cohort was similar to the general population. INTERPRETATION: We conclude that the presence of comorbidities in the EBRT population might be a relevant factor in observed excess non-pelvis SPC risk, but not for excess pelvis SPC risk.


Assuntos
Segunda Neoplasia Primária , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/epidemiologia , Segunda Neoplasia Primária/epidemiologia , Segunda Neoplasia Primária/etiologia , Idoso , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Fatores de Risco , Incidência , Radioterapia de Intensidade Modulada/efeitos adversos , Comorbidade , Fumar/epidemiologia , Fumar/efeitos adversos , Radioterapia Conformacional/efeitos adversos , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/etiologia , Sistema de Registros/estatística & dados numéricos
4.
Jpn J Clin Oncol ; 54(3): 312-318, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38010609

RESUMO

BACKGROUND: Intensity-modulated radiation therapy (IMRT) has been increasingly used as a new radiation modality for unresectable non-small cell lung cancer (NSCLC). The risk factors for radiation pneumonitis (RP) during consolidation durvalumab following concurrent chemoradiotherapy (CCRT) using IMRT have not been thoroughly investigated. METHODS: This retrospective study analyzed medical record data from consecutive patients diagnosed with NSCLC who underwent CCRT and consolidation durvalumab at our institution between April 2018 and September 2022. Since we adopted IMRT for the treatment of NSCLC in April 2020, these patients were categorized into two groups: those treated with IMRT after April 2020 and those treated with three-dimensional conformal radiotherapy (3D-CRT) before April 2020. RESULTS: A total of 31 patients underwent IMRT (the IMRT group), while 25 patients underwent 3D-CRT (the 3D-CRT group). In both groups, the total dose was 60 Gy in 30 fractions. The cumulative incidence of ≥ grade 2 RP at 12 months was significantly lower in the IMRT group than in the 3D-CRT group (27.0% vs. 64.0%, hazard ratio [HR]: 0.338, 95% confidence interval [CI]: 0.144-0.793, p = 0.013). In the multivariable analysis, V20 (≥ 25.6%, HR: 2.706, 95% CI: 1.168-6.269, p = 0.020) and radiotherapy technique (IMRT, HR: 0.414, 95% CI: 0.172-0.994, p = 0.048) were identified as significant risk factors for ≥ grade 2 RP. CONCLUSIONS: IMRT is associated with a lower rate of ≥ grade 2 RP in patients with NSCLC who received CCRT followed by durvalumab.


Assuntos
Anticorpos Monoclonais , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Pneumonite por Radiação , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/complicações , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Incidência , Pneumonite por Radiação/epidemiologia , Pneumonite por Radiação/etiologia , Estudos Retrospectivos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/complicações , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Quimiorradioterapia/efeitos adversos
5.
J Appl Clin Med Phys ; 25(2): e14153, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37698358

RESUMO

PURPOSE: This research aimed to develop a prediction model to assess bladder wall dosimetry during radiotherapy for patients with pelvic tumors, thereby facilitating the refinement and evaluation of radiotherapy treatment plans to mitigate bladder toxicity. METHODS: Radiotherapy treatment plans of 49 rectal cancer patients and 45 gynecologic cancer patients were collected, and multiple linear regression analyses were used to generate prediction models for bladder wall dose parameters ( V 10 - 45 G y ( c m 3 ) ${V_{10 - 45Gy\ }}( {{\mathrm{c}}{{\mathrm{m}}^3}} )$ , D m e a n ( Gy ) ${D_{mean}}( {{\mathrm{Gy}}} )$ ). These models were based on the multiscale spatial relationship between the planning target volume (PTV) and the bladder or bladder wall. The proportion of bladder or bladder wall volume overlapped by the different distance expansions of the PTV was used as an indicator of the multiscale spatial relationship. The accuracy of these models was verified in a cohort of 12 new patients, with further refinement of radiotherapy treatment plans using the predicted values as optimization parameters. Model accuracy was assessed using root mean square error (RMSE) and mean percentage error (MPE). RESULTS: Models derived from individual disease data outperformed those derived from combined datasets. Predicted bladder wall dose parameters were accurate, with the majority of initial calculated values for new patients falling within the 95% confidence interval of the model predictions. There was a robust correlation between the predicted and actual dose metrics, with a correlation coefficient of 0.943. Using the predicted values to optimize treatment plans significantly reduced bladder wall dose (p < $\ < \ $ 0.001), with bladder wall D mean ( G y ) ${D_{{\mathrm{mean}}}}( {Gy} )$ and V 10 - 45 G y ( c m 3 ) ${V_{10 - 45Gy\ }}( {{\mathrm{c}}{{\mathrm{m}}^3}} )$ decreasing by 2.27±0.80 Gy (5.8%±1.8%) and 2.96±2.05 cm3 (7.9%±5.4%), respectively. CONCLUSION: The formulated prediction model provides a valuable tool for predicting and minimizing bladder wall dose and for optimizing and evaluating radiotherapy treatment plans for pelvic tumor patients. This approach holds promise for reducing bladder toxicity and potentially improving patient outcomes.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Feminino , Bexiga Urinária , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
6.
J Appl Clin Med Phys ; 25(3): e14284, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38295191

RESUMO

PURPOSE: External beam radiotherapy is a complex process, involving timely coordination among multiple teams. The aim of this study is to report our experience of establishing a standardized workflow and using quantitative data and metrics to manage the time-to-treatment initiation (TTI). METHODS AND MATERIALS: Starting in 2014, we established a standard process in a radiation oncology-specific electronic medical record system (RO-EMR) for patients receiving external beam radiation therapy in our department, aiming to measure the time interval from simulation to treatment initiation, defined as TTI, for radiation oncology. TTI data were stratified according to the following treatment techniques: three-dimensional (3D) conformal therapy, intensity-modulated radiotherapy (IMRT), and stereotactic body radiotherapy (SBRT). Statistical analysis was performed with the Mann-Whitney test for the respective metrics of aggregate data for the initial period 2012- 2015 (PI) and the later period 2016-2019 (PII). RESULT: Over 8 years, the average annual number of treatments for PI and PII were 1760 and 2357 respectively, with 3D, IMRT, and SBRT treatments accounting for 53, 29, 18% and 44, 34, 22%, respectively, of the treatment techniques. The median TTI for 3D, IMRT, and SBRT for PI and PII were 1, 6, 7, and 1, 5, 7 days, respectively, while the 90th percentile TTI for the three techniques in both periods were 5, 9, 11 and 4, 9, 10 days, respectively. From the aggregate data, the TTI was significantly reduced (p = 0.0004, p < 0.0001, p < 0.0001) from PI to PII for the three treatment techniques. CONCLUSION: Establishing a standardized workflow and frequently measuring TTI resulted in shortening the TTI during the early years (in PI) and maintaining the established TTI in the subsequent years (in PII).


Assuntos
Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Radiocirurgia/métodos
7.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38778567

RESUMO

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Assuntos
Estudos de Viabilidade , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas/instrumentação , Radiocirurgia/métodos , Dosímetros de Radiação , Radioterapia Conformacional/métodos , Radioterapia Conformacional/instrumentação , Radiometria/métodos , Radiometria/instrumentação , Órgãos em Risco/efeitos da radiação , Neoplasias/radioterapia
8.
J Appl Clin Med Phys ; 25(6): e14278, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38230839

RESUMO

PURPOSE: Linear accelerator-based stereotactic radiosurgery (SRS) has become a mainstay for simultaneous management of multiple intracranial targets. Recent improvements in treatment planning systems (TPS) have enabled treatment of multiple brain metastases using dynamic conformal arcs (DCA) and a single treatment isocenter. However, as the volume of healthy tissue receiving at least 12 Gy (V12) is linked to the probability of developing radionecrosis, balancing target coverage while minimizing V12 is a critical factor affecting SRS plan quality. Current TPS allow users to adjust various parameters influencing plan optimization. The purpose of this work is to quantify the effect of negative margins on V12 for cranial SRS plans managing multiple brain metastases. METHODS: Using the Brainlab Elements v3.0 TPS (Brainlab, Munich, Germany), we calculated V10, V12, V15, monitor units, and conformity index for seventeen SRS plans treating 2-10 metastases on our Elekta Versa HD (Elekta, Stockholm, Sweden) linear accelerator. We compared plans optimized using 70%-90% prescription isodose lines (IDL) in 5% increments. RESULTS: Irrespective of the number of treated metastases, optimization at a lower prescription IDL reduced V10, V12, and V15 and increased MU compared to the 90% IDL (p < 0.01). However, comparing the 70% and 75% IDL optimizations, there was little difference in tissue sparing. The conformity index showed no consistent trends at different IDLs due to a significant spread in case data. CONCLUSION: For our plans treating up to 10 metastases, diminishing returns for tissue sparing at IDLs below 80% paired with increasing treatment MU and dosimetric hot spot made optimization at lower IDLs less favorable. In our clinic, after consulting with a physician, it was determined that optimization at the 80% IDL achieved the best balance of V12, treatment MU, and maximum dose. Clinics implementing LINAC-based SRS programs may consider using similar evaluations to develop their own clinical protocols.


Assuntos
Neoplasias Encefálicas , Órgãos em Risco , Aceleradores de Partículas , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/radioterapia , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas/instrumentação , Radioterapia de Intensidade Modulada/métodos , Tratamentos com Preservação do Órgão/métodos , Radioterapia Conformacional/métodos
9.
J Xray Sci Technol ; 32(3): 765-781, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38277334

RESUMO

BACKGROUND: SRS and SRT are precise treatments for brain metastases, delivering high doses while minimizing doses to nearby organs. Modern linear accelerators enable the precise delivery of SRS/SRT using different modalities like three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and Rapid Arc (RA). OBJECTIVE: This study aims to compare dosimetric differences and evaluate the effectiveness of 3DCRT, IMRT, and Rapid Arc techniques in SRS/SRT for brain metastases. METHODS: 10 patients with brain metastases, 3 patients assigned for SRT, and 7 patients for SRS. For each patient, 3 treatment plans were generated using the Eclipse treatment planning system using different treatment modalities. RESULTS: No statistically significant differences were observed among the three techniques in the homogeneity index (HI), maximum D2%, and minimum D98% doses for the target, with a p > 0.05. The RA demonstrated a better conformity index of 1.14±0.25 than both IMRT 1.21±0.26 and 3DCRT 1.37±0.31. 3DCRT and IMRT had lower Gradient Index values compared to RA, suggesting that they achieved a better dose gradient than RA. The mean treatment time decreased by 26.2% and 10.3% for 3DCRT and RA, respectively, compared to IMRT. In organs at risk, 3DCRT had lower maximum doses than IMRT and RA, but some differences were not statistically significant. However, in the brain stem and brain tissues, RA exhibited lower maximum doses compared to IMRT and 3DCRT. Additionally, RA and IMRT had lower V15Gy, V12Gy, and V9Gy values compared to 3DCRT. CONCLUSION: While 3D-CRT delivered lower doses to organs at risk, RA and IMRT provided better conformity and target coverage. RA effectively controlled the maximum dose and irradiated volume of normal brain tissue. Overall, these findings indicate that 3DCRT, RA, and IMRT are suitable for treating brain metastases in SRS/SRT due to their improved dose conformity and target coverage while minimizing dose to healthy tissues.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Estudos de Viabilidade , Masculino , Feminino , Radioterapia Conformacional/métodos , Pessoa de Meia-Idade , Idoso
10.
Strahlenther Onkol ; 199(1): 90-101, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35943553

RESUMO

PURPOSE: The purpose of this study was to compare two techniques of irradiation of left-sided breast cancer patients who underwent breast-conserving surgery, three-dimensional conformal radiotherapy technique (3D-CRT) and volumetric modulated arc therapy (VMAT), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim of the study was estimation of the projected risk of radiation-induced secondary cancer for both radiotherapy techniques. MATERIALS AND METHODS: For 25 patients who underwent CT simulation in deep inspiration breath-hold (DIBH), three treatment plans were generated: one using a three-dimensional conformal radiotherapy technique and two using volumetric modulated arc therapy. First VMAT-DIBH geometry consisted of three partial arcs (ARC-DIBH 3A) and second consisted of four partial arcs (ARC-DIBH 4A). Cumulative dose-volume histograms (DVHs) were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery [LAD], ipsilateral and contralateral lung [IL, CL], and contralateral breast [CB]). Normal tissue complication probabilities (NTCPs) and organ equivalent doses (OEDs) were calculated using the differential DVHs. Excess absolute risks (EARs) for second cancers were estimated using Schneider's full mechanistic dose-response model. RESULTS: All plans fulfilled the criterium for PTV V95% ≥ 95%. The PTV coverage, homogeneity, and conformity indices were significantly better for VMAT-DIBH. VMAT showed a significantly increased mean dose and V5Gy for all OARs, but reduced LAD Dmax by 15 Gy. For IL, CL, and CB, the 3D-CRT DIBH method achieved the lowest values of EAR: 28.38 per 10,000 PYs, 2.55 per 10,000 PYs, and 4.48 per 10,000 PYs (p < 0.001), compared to 40.29 per 10,000 PYs, 15.62 per 10,000 PYs, and 23.44 per 10,000 PYs for ARC-DIBH 3A plans and 41.12 per 10,000 PYs, 15.59 per 10,000 PYs, and 22.73 per 10,000 PYs for ARC-DIBH 4A plans. Both techniques provided negligibly low NTCPs for all OARs. CONCLUSION: The study shows that VMAT-DIBH provides better OAR sparing against high doses. However, the large low-dose-bath (≤ 5 Gy) is still a concern due to the fact that a larger volume of normal tissues exposed to lower doses may increase a radiation-induced risk of secondary cancer.


Assuntos
Neoplasias da Mama , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/radioterapia , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Órgãos em Risco/efeitos da radiação
11.
Gynecol Oncol ; 175: 176-181, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37393743

RESUMO

INTRODUCTION: NRG/RTOG 1203 compared 3-D conformal radiotherapy (3D CRT) to intensity-modulated radiotherapy (IMRT) in patients with endometrial or cervical cancer requiring post-operative radiotherapy after hysterectomy. The purpose of this study was to report the first quality-adjusted survival analysis comparing the two treatments. METHODS: NRG/RTOG 1203 randomized patients having undergone hysterectomy to either 3DCRT or IMRT. Stratification factors included RT dose, chemotherapy, and disease site. The EQ-5D, both index and visual analog scale (VAS), were obtained at baseline, 5 weeks after the start of RT, 4-6 weeks post RT and 1 and 3-years post RT. EQ-5D index and VAS scores along with quality-adjusted survival (QAS) were compared between treatment arms using the t-test at a two-sided significance level of 0.05. RESULTS: NRG/RTOG 1203 enrolled 289 patients of which 236 consented to participate in the patient reported outcome (PRO) assessments. QAS was higher in women treated with IMRT, 1374 vs 1333 days (p = 0.5) compared to patients treated with 3DCRT, but this difference was not statistically different. Patients treated with IMRT had less of a decline in VAS score 5 weeks post RT, -5.04, compared to patients treated with 3DCRT, -7.48, although not statistically significant (p = 0.38). CONCLUSION: This is the first report of the use of the EQ-5D comparing two radiotherapy techniques in the treatment of gynecologic malignancies after surgery. While there were no significant differences in QAS and VAS scores between patients who received IMRT vs. 3DCRT, RTOG 1203 was not powered to show statistical differences in these secondary endpoints.


Assuntos
Neoplasias dos Genitais Femininos , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias dos Genitais Femininos/etiologia , Radioterapia Conformacional/efeitos adversos , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/cirurgia , Neoplasias do Colo do Útero/etiologia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
12.
J Neurooncol ; 164(2): 271-286, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37624529

RESUMO

Despite aggressive management consisting of surgery, radiation therapy (RT), and systemic therapy given alone or in combination, a significant proportion of patients with brain tumors will experience tumor recurrence. For these patients, no standard of care exists and management of either primary or metastatic recurrent tumors remains challenging.Advances in imaging and RT technology have enabled more precise tumor localization and dose delivery, leading to a reduction in the volume of health brain tissue exposed to high radiation doses. Radiation techniques have evolved from three-dimensional (3-D) conformal RT to the development of sophisticated techniques, including intensity modulated radiation therapy (IMRT), volumetric arc therapy (VMAT), and stereotactic techniques, either stereotactic radiosurgery (SRS) or stereotactic radiotherapy (SRT). Several studies have suggested that a second course of RT is a feasible treatment option in patients with a recurrent tumor; however, survival benefit and treatment related toxicity of reirradiation, given alone or in combination with other focal or systemic therapies, remain a controversial issue.We provide a critical overview of the current clinical status and technical challenges of reirradiation in patients with both recurrent primary brain tumors, such as gliomas, ependymomas, medulloblastomas, and meningiomas, and brain metastases. Relevant clinical questions such as the appropriate radiation technique and patient selection, the optimal radiation dose and fractionation, tolerance of the brain to a second course of RT, and the risk of adverse radiation effects have been critically discussed.


Assuntos
Neoplasias Encefálicas , Neoplasias Cerebelares , Radiocirurgia , Radioterapia Conformacional , Reirradiação , Humanos , Reirradiação/métodos , Recidiva Local de Neoplasia/radioterapia , Recidiva Local de Neoplasia/cirurgia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Radioterapia Conformacional/métodos , Neoplasias Cerebelares/cirurgia
13.
Pediatr Blood Cancer ; 70(11): e30627, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37580901

RESUMO

PURPOSE: Three-dimensional conformal RT (3D-RT) techniques are gold standard for post-operative flank radiotherapy (RT) in paediatric renal tumours. Recently, highly conformal RT (HC-RT) techniques have been implemented without comparative clinical data. The main objective of this multicentre study was to compare locoregional control (LRC) in children treated either with HC-RT or 3D-RT techniques. METHODS: Patients treated with post-operative flank RT for renal tumour registered in the national cohort PediaRT between March 2013 and September 2019 were included. Treatment and follow-up data, including toxicities and outcomes, were retrieved from the database. LRC was calculated, and dose reconstruction was performed in case of an event. RESULTS: Seventy-nine patients were included. Forty patients were treated with HC-RT and 39 with 3D-RT. Median follow-up was 4.5 years. Three patients had locoregional failure (LRF; 4%). HC-RT was not associated with a higher risk of LRF. Three-year LRC were 97.4% and 94.7% in the HC-RT and 3D-RT groups, respectively. The proportion of planning target volumes receiving 95% or more of the prescribed dose did not significantly differ between both groups (HC-RT 88%; 3D-RT 69%; p = .05). HC-RT was better achieving dose constraints, and a significant mean dose reduction was observed in the peritoneal cavity and pancreas associated with lower incidence of acute gastrointestinal toxicity. CONCLUSION: LRF after post-operative flank RT for renal tumours was rare and did not increase using HC-RT versus 3D-RT techniques. Dose to the pancreas and the peritoneal cavity, as well as acute toxicity, were reduced with HC-RT compared to 3D-RT.


Assuntos
Neoplasias Renais , Radioterapia Conformacional , Criança , Humanos , Neoplasias Renais/radioterapia , Neoplasias Renais/cirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos
14.
Pediatr Blood Cancer ; 70 Suppl 6: e30593, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37486145

RESUMO

Radiation oncology is an integral part of the multidisciplinary team caring for children with cancer. The primary goal of our committee is to enable the delivery of the safest dose of radiation therapy (RT) with the maximal potential for cure, and to minimize toxicity in children by delivering lower doses to normal tissues using advanced technologies like intensity-modulated RT (IMRT) and proton therapy. We provide mentorship for y ators and are actively involved in educating the global radiation oncology community. We are leaders in the effort to discover novel radiosensitizers, radioprotectors, and advanced RT technologies that could help improve outcomes of children with cancer.


Assuntos
Neoplasias , Radioterapia (Especialidade) , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Criança , Neoplasias/radioterapia , Oncologia
15.
Pediatr Blood Cancer ; 70(3): e30164, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36591994

RESUMO

PURPOSE: Pediatric patients with medulloblastoma in low- and middle-income countries (LMICs) are most treated with 3D-conformal photon craniospinal irradiation (CSI), a time-consuming, complex treatment to plan, especially in resource-constrained settings. Therefore, we developed and tested a 3D-conformal CSI autoplanning tool for varying patient lengths. METHODS AND MATERIALS: Autocontours were generated with a deep learning model trained:tested (80:20 ratio) on 143 pediatric medulloblastoma CT scans (patient ages: 2-19 years, median = 7 years). Using the verified autocontours, the autoplanning tool generated two lateral brain fields matched to a single spine field, an extended single spine field, or two matched spine fields. Additional spine subfields were added to optimize the corresponding dose distribution. Feathering was implemented (yielding nine to 12 fields) to give a composite plan. Each planning approach was tested on six patients (ages 3-10 years). A pediatric radiation oncologist assessed clinical acceptability of each autoplan. RESULTS: The autocontoured structures' average Dice similarity coefficient ranged from .65 to .98. The average V95 for the brain/spinal canal for single, extended, and multi-field spine configurations was 99.9% ± 0.06%/99.9% ± 0.10%, 99.9% ± 0.07%/99.4% ± 0.30%, and 99.9% ± 0.06%/99.4% ± 0.40%, respectively. The average maximum dose across all field configurations to the brainstem, eyes (L/R), lenses (L/R), and spinal cord were 23.7 ± 0.08, 24.1 ± 0.28, 13.3 ± 5.27, and 25.5 ± 0.34 Gy, respectively (prescription = 23.4 Gy/13 fractions). Of the 18 plans tested, all were scored as clinically acceptable as-is or clinically acceptable with minor, time-efficient edits preferred or required. No plans were scored as clinically unacceptable. CONCLUSION: The autoplanning tool successfully generated pediatric CSI plans for varying patient lengths in 3.50 ± 0.4 minutes on average, indicating potential for an efficient planning aid in a resource-constrained settings.


Assuntos
Neoplasias Cerebelares , Radiação Cranioespinal , Meduloblastoma , Radioterapia Conformacional , Humanos , Criança , Pré-Escolar , Adolescente , Adulto Jovem , Adulto , Meduloblastoma/radioterapia , Planejamento da Radioterapia Assistida por Computador , Neoplasias Cerebelares/diagnóstico por imagem , Neoplasias Cerebelares/radioterapia , Dosagem Radioterapêutica
16.
Acta Oncol ; 62(5): 473-479, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37154167

RESUMO

PURPOSE/OBJECTIVES: Proton beam therapy (PBT) may provide a dosimetric advantage in sparing soft tissue and bone for selected patients with extremity soft sarcoma (eSTS). We compared PBT with photons plans generated using intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). MATERIALS/METHODS: Seventeen patients previously treated with pencil beam scanning PBT were included in this study. Of these patients, 14 treated with pre-operative 50 Gy in 25 fractions were analyzed. IMRT and 3D-CRT plans were created to compare against the original PBT plans. Dose-volume histogram (DVH) indices were evaluated amongst PBT, IMRT, and 3D plans. Kruskal-Wallis rank sum tests were used to get the statistical significance. A p value smaller than .05 was considered to be statistically significant. RESULTS: For the clinical target volume (CTV), D2%, D95%, D98%, Dmin, Dmax, and V50Gy, were assessed. Dmin, D1%, Dmax, Dmean, V1Gy, V5Gy, and V50Gy were evaluated for the adjacent soft tissue. D1%, Dmax, Dmean, and V35-50% were evaluated for bone. All plans met CTV target coverage. The PBT plans delivered less dose to soft tissue and bone. The mean dose to the soft tissue was 2 Gy, 11 Gy, and 13 Gy for PBT, IMRT, and 3D, respectively (p < .001). The mean dose to adjacent bone was 15 Gy, 26 Gy, and 28 Gy for PBT, IMRT, and 3D, respectively (p = .022). CONCLUSION: PBT plans for selected patients with eSTS demonstrated improved sparing of circumferential soft tissue and adjacent bone compared to IMRT and 3D-CRT. Further evaluation will determine if this improved dosimetry correlates with reduced toxicity and improved quality of life.


Assuntos
Terapia com Prótons , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Sarcoma , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Qualidade de Vida , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Sarcoma/radioterapia
17.
Acta Oncol ; 62(10): 1169-1177, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37812070

RESUMO

BACKGROUND: Volumetric Modulated Arc Therapy (VMAT) offers better conformity, homogeneity and sparing of the heart and ipsilateral lung for locoregional radiotherapy in left-sided breast cancer compared to three-dimensional conformal radiotherapy (3D-CRT). However, conventional coplanar VMAT (cVMAT) can result in higher doses to the normal tissue on the contralateral side. This study investigates a non-coplanar VMAT-technique (ncVMAT) to mitigate this issue. MATERIAL AND METHODS: CT series of 20 left sided breast cancer patients were included for planning of locoregional breast radiotherapy including internal mammary nodes (IMN). Three treatment plans; 3D-CRT, cVMAT and ncVMAT, were generated for each patient with a prescription dose of 40.05 Gy in 15 fractions. Both VMAT-techniques consisted of a single arc in the axial plane, while ncVMAT included an additional arc in the sagittal plane. All plans were optimized to cover the clinical target volume (CTV) by 38.05 Gy for the breast and 36.05 Gy for lymph nodes, with as low as possible dose to organs at risk. RESULTS: Full CTV coverage was achieved for all plans. Both cVMAT and ncVMAT delivered more conformal and homogeneous target doses than 3D-CRT. Doses to the heart and ipsilateral lung were significantly lower with ncVMAT compared to both cVMAT and 3D-CRT. ncVMAT reduced doses to both the contralateral breast and lung compared to cVMAT and achieved levels similar to 3D-CRT for the contralateral breast and moderately higher doses for the contralateral lung. Delivery of high doses (>30 Gy) to the contralateral side was completely avoided with ncVMAT, contrary to the results for cVMAT and 3D-CRT. CONCLUSION: ncVMAT reduced doses to the heart and ipsilateral lung as compared to both cVMAT and 3D-CRT. All contralateral dose metrics were reduced with the novel ncVMAT technique compared to cVMAT, and the mean contralateral breast doses were similar to 3D-CRT.


Assuntos
Neoplasias da Mama , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Mama , Dosagem Radioterapêutica , Linfonodos , Órgãos em Risco
18.
Acta Oncol ; 62(8): 932-941, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37516978

RESUMO

PURPOSE: The purpose of this study was to evaluate three techniques of irradiation of left-sided breast cancer patients, three-dimensional conformal radiotherapy (3D-CRT), hybrid Intensity-Modulated Radiotherapy (h-IMRT), and hybrid Volumetric-Modulated Arc Therapy (h-VMAT, h-ARC), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim was to estimate the projected relative risk of radiation-induced secondary cancers for hybrid techniques. MATERIALS AND METHODS: Three treatment plans were prepared in 3D-CRT, h-IMRT, and h-VMAT techniques for each of the 40 patients, who underwent CT simulation in deep inspiration breath-hold (DIBH). For hybrid techniques, plans were created by combining 3D-CRT and dynamic fields with an 80%/20% dose ratio for 3D-CRT and IMRT or VMAT. Cumulative dose-volume histograms were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery [LAD], left and right lung [LL, RL], right breast [RB]). Projected risk ratios for secondary cancers were estimated relative to 3D-CRT using the organ equivalent dose (OED) concept for the Schneider's linear exponential, plateau, and full mechanistic dose-response model. RESULTS: All plans fulfilled the PTV criterium: V95%≥95%. Compared to 3D-CRT, both hybrid techniques showed significantly better target coverage (PTV: V95%>98%, p < 0.001), and the best conformality was achieved by h-ARC plans (CI: 1.18 ± 0.09, p < 0.001). Compared to 3D-CRT and h-ARC, h-IMRT increased the average sum of monitor units (MU) over 129.9% (p < 0.001). H-ARC increased the mean dose of contralateral organs and the LL V5Gy parameter (p < 0.001). Both hybrid techniques significantly reduced the Dmax of the heart by 5 Gy. Compared to h-IMRT, h-ARC increased secondary cancer projected relative risk ratios for LL, RL, and RB by 18, 152, and 81%, respectively. CONCLUSIONS: The results confirmed that both hybrid techniques provide better target quality and OARs sparing than 3D-CRT. Hybrid VMAT delivers less MU compared to hybrid IMRT but may increase the risk of radiation-induced secondary malignancies.


Assuntos
Neoplasias da Mama , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Neoplasias Unilaterais da Mama/radioterapia , Risco , Neoplasias da Mama/radioterapia , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Segunda Neoplasia Primária/etiologia , Órgãos em Risco/efeitos da radiação
19.
Jpn J Clin Oncol ; 53(12): 1177-1182, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37599064

RESUMO

BACKGROUND: Although the trend in radiotherapy in all cancer patients has been studied, changes in radiotherapy modalities for specific cancer types have not been reported. This study aimed to analyze radiotherapy patterns for major cancers in Korea in recent years. MATERIALS AND METHODS: We collected data from claims and reimbursement records of the Health and Insurance Review and Assessment Service from 2017 to 2020, according to initial diagnostic codes. The radiotherapy modalities for major cancers, such as lung, stomach, colorectal, breast and liver cancer, were analyzed. The radiotherapy modalities consisted of two-dimensional radiotherapy, three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, proton radiotherapy and stereotactic body radiotherapy. RESULTS: Overall, from 2017 to 2020, the use of two-dimensional radiotherapy and three-dimensional conformal radiotherapy decreased, and intensity-modulated radiotherapy increased. In 2017, three-dimensional conformal radiotherapy accounted for approximately half of the radiotherapy in patients for lung and colorectal cancer, which was replaced by intensity-modulated radiotherapy in 2020. In 2020, stereotactic body radiotherapy also accounted for a large proportion of radiotherapy used in liver cancer cases. Intensity-modulated radiotherapy was most used, followed by three-dimensional conformal radiotherapy and two-dimensional radiotherapy for breast cancer in 2020. Among major cancers, radiotherapy utilization for breast cancer is the highest. Compared with other cancers, the number of patients receiving radiotherapy for stomach cancer was low. CONCLUSION: The number of patients receiving radiotherapy for major cancers has increased. The use of advanced forms of radiotherapy, such as intensity-modulated radiotherapy, is rapidly increasing for major cancers. The rate of radiotherapy utilization was higher in major cancer patients than in all cancer patients.


Assuntos
Neoplasias da Mama , Neoplasias Hepáticas , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Feminino , Radioterapia Conformacional/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias Hepáticas/radioterapia , República da Coreia/epidemiologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
20.
Int J Gynecol Cancer ; 33(8): 1295-1303, 2023 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-37041022

RESUMO

Since the National Cancer Institute (NCI) alert of concurrent chemoradiotherapy, radiotherapy has been changed from external beam radiotherapy plus brachytherapy to platinum-based concurrent chemoradiotherapy. Therefore, concurrent chemoradiotherapy plus brachytherapy has become a standard treatment for locally advanced cervical cancer. Simultaneously, definitive radiotherapy has been changed gradually from external beam radiotherapy plus low-dose-rate intracavitary brachytherapy to external beam radiotherapy plus high-dose-rate intracavitary brachytherapy. Cervix cancer is uncommon in developed countries; hence, international collaborations have been critical in large-scale clinical trials. The Cervical Cancer Research Network (CCRN), created from the Gynecologic Cancer InterGroup (GCIG), has investigated various concurrent chemotherapy regimens and sequential methods of radiation and chemotherapy. Most recently, many clinical trials of combining immune checkpoint inhibitors with radiotherapy have been ongoing for sequential or concurrent settings. During the last decade, the method of standard radiation therapy has changed from three-dimensional conformal radiation therapy to intensity-modulated radiation therapy for external beam radiotherapy and from two-dimensional to three-dimensional image-guided approaches for brachytherapy. Recent improvements include stereotactic ablative body radiotherapy and MRI-guided linear accelerator (MRI-LINAC) using adaptive radiotherapy. Here we review the current progress of radiation therapy during the last two decades.


Assuntos
Braquiterapia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/tratamento farmacológico , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Quimiorradioterapia , Braquiterapia/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa