Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.891
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Magn Reson Med ; 90(5): 1905-1918, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37392415

RESUMO

PURPOSE: To present the validation of a new Flexible Ultra-Short Echo time (FUSE) pulse sequence using a short-T2 phantom. METHODS: FUSE was developed to include a range of RF excitation pulses, trajectories, dimensionalities, and long-T2 suppression techniques, enabling real-time interchangeability of acquisition parameters. Additionally, we developed an improved 3D deblurring algorithm to correct for off-resonance artifacts. Several experiments were conducted to validate the efficacy of FUSE, by comparing different approaches for off-resonance artifact correction, variations in RF pulse and trajectory combinations, and long-T2 suppression techniques. All scans were performed on a 3 T system using an in-house short-T2 phantom. The evaluation of results included qualitative comparisons and quantitative assessments of the SNR and contrast-to-noise ratio. RESULTS: Using the capabilities of FUSE, we demonstrated that we could combine a shorter readout duration with our improved deblurring algorithm to effectively reduce off-resonance artifacts. Among the different RF and trajectory combinations, the spiral trajectory with the regular half-inc pulse achieves the highest SNRs. The dual-echo subtraction technique delivers better short-T2 contrast and superior suppression of water and agar signals, whereas the off-resonance saturation method successfully suppresses water and lipid signals simultaneously. CONCLUSION: In this work, we have validated the use of our new FUSE sequence using a short T2 phantom, demonstrating that multiple UTE acquisitions can be achieved within a single sequence. This new sequence may be useful for acquiring improved UTE images and the development of UTE imaging protocols.


Assuntos
Imageamento por Ressonância Magnética , Técnica de Subtração , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Artefatos , Água , Imageamento Tridimensional/métodos
2.
AJR Am J Roentgenol ; 220(1): 63-72, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35946861

RESUMO

BACKGROUND. Coronary CTA with hybrid iterative reconstruction (HIR) is prone to false-positive results for in-stent restenosis due to stent-related blooming artifact. OBJECTIVE. The purpose of this study is to assess the impact of deep learning reconstruction (DLR), subtraction images, and the combination of DLR and subtraction images on the diagnostic performance of coronary CTA for the detection of in-stent restenosis. METHODS. This prospective study included patients with coronary stents who underwent coronary CTA between March 2020 and August 2021. CTA used a technique with two breath-holds (noncontrast and contrast-enhanced acquisitions). Conventional and subtraction images were reconstructed for HIR and DLR. The maximum visible instent lumen diameter was measured. Two readers independently evaluated images for in-stent restenosis (≥ 50% stenosis). A simulated assessment of combined conventional and subtraction images was generated, reflecting assessment of conventional and subtraction images in the presence or absence of severe misregistration artifact, respectively. Invasive angiography served as reference standard. RESULTS. The study enrolled 30 patients (22 men and eight women; mean age, 63.6 ± 7.4 [SD] years) with a total of 59 stents; severe misregistration artifact was present for 32 stents. Maximum visible in-stent lumen diameter was higher for DLR than for HIR (2.3 ± 0.5 vs 2.1 ± 0.5 mm, p < .001), and among stents without severe misregistration artifact, it was higher for subtraction than conventional DLR (3.0 ± 0.5 vs 2.4 ± 0.5, p < .001). Among conventional CTA with HIR, conventional CTA with DLR, combination (conventional and subtraction) approach with HIR, and combination (conventional and subtraction) approach with DLR, the highest patient-level diagnostic performance measures were as follows: for reader 1, sensitivity was identical (62.5%), specificity was highest for combination with DLR (90.1%), PPV was highest for combination with DLR (71.4%), NPV was highest for combination with DLR (87.0%), and accuracy was highest for combination with DLR (83.3%); for reader 2, sensitivity was identical (50.0%), specificity was highest for combination with HIR or DLR (both 95.5%), PPV was highest for combination with HIR or DLR (both 80.0%), NPV was highest for combination with HIR or DLR (84.0%), and accuracy was highest for combination with HIR or DLR (both 83.3%). CONCLUSION. The combined DLR and subtraction technique yielded optimal diagnostic performance for detecting in-stent restenosis by coronary CTA. CLINICAL IMPACT. The described technique could guide patient selection for invasive coronary stent evaluation.


Assuntos
Reestenose Coronária , Aprendizado Profundo , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Angiografia Coronária/métodos , Vasos Coronários , Estudos Prospectivos , Técnica de Subtração , Stents
3.
Neuroimage ; 245: 118708, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34743050

RESUMO

INTRODUCTION: Electroencephalography (EEG) is increasingly used to investigate brain responses to transcranial magnetic stimulation (TMS). A relevant issue is that TMS is associated with considerable auditory and somatosensory stimulation, causing peripherally evoked potentials (PEPs) in the EEG, which contaminate the direct cortical responses to TMS (TEPs). All previous attempts to control for PEPs suffer from significant limitations. OBJECTIVE/HYPOTHESIS: To design an optimized sham procedure to control all sensory input generated by subthreshold real TMS targeting the hand area of the primary motor cortex (M1), enabling reliable separation of TEPs from PEPs. METHODS: In 23 healthy (16 female) subjects, we recorded EEG activity evoked by an optimized sham TMS condition which masks and matches auditory and somatosensory co-stimulation during the real TMS condition: auditory control was achieved by noise masking and by using a second TMS coil that was placed on top of the real TMS coil and produced a calibrated sound pressure level. Somatosensory control was obtained by electric stimulation (ES) of the scalp with intensities sufficient to saturate somatosensory input. ES was applied in both the sham and real TMS conditions. Perception of auditory and somatosensory inputs in the sham and real TMS conditions were compared by psychophysical testing. Transcranially evoked EEG signal changes were identified by subtraction of EEG activity in the sham condition from EEG activity in the real TMS condition. RESULTS: Perception of auditory and somatosensory inputs in the sham vs. real TMS conditions was comparable. Both sham and real TMS evoked a series of similar EEG signal deflections and induced broadband power increase in oscillatory activity. Notably, the present procedure revealed EEG potentials and a transient increase in beta band power at the site of stimulation that were only present in the real TMS condition. DISCUSSION: The results validate the effectiveness of our optimized sham approach. Despite the presence of typical responses attributable to sensory input, the procedure provided evidence for direct cortical activation by subthreshold TMS of M1. The findings are relevant for future TMS-EEG experiments that aim at measuring regional brain target engagement controlled by an optimized sham procedure.


Assuntos
Eletroencefalografia , Córtex Somatossensorial/fisiologia , Estimulação Magnética Transcraniana , Adulto , Potenciais Evocados/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Técnica de Subtração
4.
Magn Reson Med ; 85(2): 694-708, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32754954

RESUMO

PURPOSE: To correct the intensity difference of static background signal between bright blood images and dark blood images in subtractive non-contrast-enhanced MR angiography using robust regression, thereby improving static background signal suppression on subtracted angiograms. METHODS: Robust regression (RR), using iteratively reweighted least squares, is used to calculate the regression coefficient of background tissues from a scatter plot showing the voxel intensity of bright blood images versus dark blood images. The weighting function is based on either the Euclidean distance from the estimated regression line or the deviation angle. Results from RR using the deviation angle (RRDA), conventional RR using the Euclidean distance, and ordinary leastsquares regression were compared with reference values determined manually by two observers. Performance was evaluated over studies using different sequences, including 36 thoracic flow-sensitive dephasing data sets, 13 iliac flow-sensitive dephasing data sets, and 26 femoral fresh blood imaging data sets. RESULTS: RR deviation angle achieved robust and accurate performance in all types of images, with small bias, small mean absolute error, and high-correlation coefficients with reference values. Background tissues, such as muscle, veins, and bladder, were suppressed while the vascular signal was preserved. Euclidean distance gave good performance for thoracic and iliac flow-sensitive dephasing, but could not suppress background tissues in femoral fresh blood imaging. Ordinary least squares regression was sensitive to outliers and overestimated regression coefficients in thoracic flow-sensitive dephasing. CONCLUSION: Weighted subtraction using RR was able to acquire the regression coefficients of background signal and improve background suppression of subtractive non-contrast-enhanced MR angiography techniques. RR deviation angle has the most robust and accurate overall performance among three regression methods.


Assuntos
Meios de Contraste , Angiografia por Ressonância Magnética , Artéria Femoral , Sensibilidade e Especificidade , Técnica de Subtração
5.
Magn Reson Med ; 86(1): 320-334, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33645815

RESUMO

PURPOSE: To develop an improved reconstruction method, k-space subtraction with phase and intensity correction (KSPIC), for highly accelerated, subtractive, non-contrast-enhanced MRA. METHODS: The KSPIC method is based on k-space subtraction of complex raw data. It applies a phase-correction procedure to restore the polarity of negative signals caused by subtraction and an intensity-correction procedure to improve background suppression and thereby sparsity. Ten retrospectively undersampled data sets and 10 groups of prospectively undersampled data sets were acquired in 12 healthy volunteers. The performance of KSPIC was compared with another improved reconstruction based on combined magnitude subtraction, as well as with conventional k-space subtraction reconstruction and magnitude subtraction reconstruction, both using quantitative metrics and using subjective quality scoring. RESULTS: In the quantitative evaluation, KSPIC had the best performance in terms of peak SNR, structural similarity index measure, contrast-to-noise ratio of artery-to-background and sharpness, especially at high acceleration factors. The KSPIC method also had the highest subjective scores for all acceleration factors in terms of vessel delineation, image noise and artifact, and background contamination. The acquisition can be accelerated by a factor of 20 without significant decreases of subjective scores. The optimal size of the phase-correction region was found to be 12-20 pixels in this study. CONCLUSION: Compared with combined magnitude subtraction and conventional reconstructions, KSPIC has the best performance in all of the quantitative and qualitative measurements, permitting good image quality to be maintained up to higher accelerations. The KSPIC method has the potential to further reduce the acquisition time of subtractive MRA for clinical examinations.


Assuntos
Angiografia por Ressonância Magnética , Técnica de Subtração , Artefatos , Artéria Femoral/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Estudos Retrospectivos
6.
NMR Biomed ; 34(2): e4423, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33029872

RESUMO

Noninvasive measurements of liver perfusion and fibrosis in cirrhotic small animals can help develop treatments for haemodynamic complications of liver disease. Here, we measure liver perfusion in cirrhotic rodents using flow-sensitive alternating inversion recovery arterial spin labelling (FAIR ASL), evaluating agreement with previously validated caval subtraction phase-contrast magnetic resonance imaging (PCMRI) total liver blood flow (TLBF). Baseline differences in cirrhotic rodents and the haemodynamic effects of acute inflammation were investigated using FAIR ASL and tissue T1. Sprague-Dawley rats (nine bile duct ligated [BDL] and ten sham surgery controls) underwent baseline hepatic FAIR ASL with T1 measurement and caval subtraction PCMRI (with two-dimensional infra-/supra-hepatic inferior vena caval studies), induction of inflammation with intravenous lipopolysaccharide (LPS) and repeat liver FAIR ASL with T1 measurement after ~90 minutes. The mean difference between FAIR ASL hepatic perfusion and caval subtraction PCMRI TLBF was -51 ± 30 ml/min/100 g (Bland-Altman 95% limits-of-agreement ±258 ml/min/100 g). The FAIR ASL coefficient of variation was smaller than for caval subtraction PCMRI (29.3% vs 50.1%; P = .03). At baseline, FAIR ASL liver perfusion was lower in BDL rats (199 ± 32 ml/min/100 g vs sham 316 ± 24 ml/min/100 g; P = .01) but liver T1 was higher (BDL 1533 ± 50 vs sham 1256 ± 18 ms; P = .0004). Post-LPS FAIR ASL liver perfusion response differences were observed between sham/BDL rats (P = .02), approaching significance in sham (+78 ± 33 ml/min/100 g; P = .06) but not BDL rats (-49 ± 40 ml/min/100 g; P = .47). Post-LPS differences in liver tissue T1 were nonsignificant (P = .35). FAIR ASL hepatic perfusion and caval subtraction PCMRI TLBF agreement was modest, with significant baseline FAIR ASL liver perfusion and tissue T1 differences in rodents with advanced cirrhosis compared with controls. Following inflammatory stress, differences in hepatic perfusion response were detected between cirrhotic/control animals, but liver T1 was unaffected. Findings underline the potential of FAIR ASL in the assessment of vasoactive treatments for patients with chronic liver disease and inflammation.


Assuntos
Cirrose Hepática Experimental/metabolismo , Angiografia por Ressonância Magnética/métodos , Animais , Área Sob a Curva , Ductos Biliares , Doença Hepática Induzida por Substâncias e Drogas/metabolismo , Doença Hepática Induzida por Substâncias e Drogas/patologia , Modelos Animais de Doenças , Inflamação , Ligadura , Lipopolissacarídeos/toxicidade , Circulação Hepática , Cirrose Hepática Experimental/patologia , Masculino , Ratos , Ratos Sprague-Dawley , Marcadores de Spin , Técnica de Subtração , Veia Cava Inferior/fisiopatologia
7.
Eur Radiol ; 31(7): 5160-5171, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33439320

RESUMO

OBJECTIVES: To compare image quality and radiation dose between dual-energy subtraction (DES)-based bone suppression images (D-BSIs) and software-based bone suppression images (S-BSIs). METHODS: Chest radiographs (CXRs) of forty adult patients were obtained with the two X-ray devices, one with DES and one with bone suppression software. Three image quality metrics (relative mean absolute error (RMAE), peak signal-to-noise ratio (PSNR), and structural similarity index (SSIM)) between original CXR and BSI for each of D-BSI and S-SBI groups were calculated for each bone and soft tissue areas. Two readers rated the visual image quality for original CXR and BSI for each of D-BSI and S-SBI groups. The dose area product (DAP) values were recorded. Paired t test was used to compare the image quality and DAP values between D-BSI and S-BSI groups. RESULTS: In bone areas, S-BSIs had better SSIM values than D-BSI (94.57 vs. 87.77) but worse RMAE and PSNR values (0.50 vs. 0.20; 20.93 vs. 34.37) (all p < 0.001). In soft tissue areas, S-BSIs had better SSIM values than D-BSI (97.56 vs. 91.42) but similar RMAE and PSNR values (0.29 vs. 0.27; 31.35 vs. 29.87) (all p < 0.001). Both readers gave S-BSIs significantly higher image quality scores than D-BSI (p < 0.001). The mean DAP in software-related images (0.98 dGy·cm2) was significantly lower than that in the DES-related images (1.48 dGy·cm2) (p < 0.001). CONCLUSION: Bone suppression software significantly improved the image quality of bone suppression images with a relatively lower radiation dose, compared with dual-energy subtraction technique. KEY POINTS: • Bone suppression software preserves structure similarity of soft tissues better than dual-energy subtraction technique in bone suppression images. • Bone suppression software achieves superior image quality for lung lesions than dual-energy subtraction technique in bone suppression images. • Bone suppression software can decrease the radiation dose over the hardware-based image processing technique.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Radiografia Torácica , Adulto , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Técnica de Subtração
8.
Pacing Clin Electrophysiol ; 44(1): 135-144, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33283875

RESUMO

INTRODUCTION: Causes of non-response to cardiac resynchronization therapy (CRT) include mechanical dyssynchrony, myocardial scar, and suboptimal left ventricular (LV) lead location. We aimed to assess the utility of Late Iodine Enhancement Computed Tomography (LIE-CT) with image subtraction in characterizing CRT non-response. METHODS: CRT response was defined as a decrease in LV end-systolic volume > 15% at 6 months. LIE-CT was performed after 6 months, and analyzed global and segmental dyssynchrony, myocardial scar, coronary venous anatomy, and position of LV lead relative to scar and segment of latest mechanical contraction. RESULTS: We evaluated 29 patients (age 71 ± 12 years; 72% men) including 18 (62%) responders. All metrics evaluating residual dyssynchrony such as wall motion index and wall thickness index were worse in non-responders. There was no difference in presence and extent of scar between responders and non-responders. However, in non-responders, the LV lead was more often over an akinetic/dyskinetic area (72% vs. 22%, p = .007), a fibrotic area (64% vs. 8%, p = .0007), an area with myocardial thickness < 6 mm (82% vs. 22%, p = .002), and less often concordant with the region of maximal wall thickness (9% vs. 72%, p = .001). Among the 11 non-responders, eight had at least another coronary venous branch visualized by CT, including three (27%) coursing over a potentially interesting myocardial area (free of scar, with normal wall motion, and with a myocardial thickness ≥6 mm). CONCLUSION: LIE-CT with image subtraction allows a comprehensive characterization of patients after CRT and may provide clues for management of non-responders.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Tomografia Computadorizada por Raios X , Falha de Tratamento , Idoso , Terapia de Ressincronização Cardíaca , Meios de Contraste , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Técnica de Subtração
9.
Proc Natl Acad Sci U S A ; 115(9): E2105-E2114, 2018 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-29440410

RESUMO

"Functional connectivity" techniques are commonplace tools for studying brain organization. A critical element of these analyses is to distinguish variance due to neurobiological signals from variance due to nonneurobiological signals. Multiecho fMRI techniques are a promising means for making such distinctions based on signal decay properties. Here, we report that multiecho fMRI techniques enable excellent removal of certain kinds of artifactual variance, namely, spatially focal artifacts due to motion. By removing these artifacts, multiecho techniques reveal frequent, large-amplitude blood oxygen level-dependent (BOLD) signal changes present across all gray matter that are also linked to motion. These whole-brain BOLD signals could reflect widespread neural processes or other processes, such as alterations in blood partial pressure of carbon dioxide (pCO2) due to ventilation changes. By acquiring multiecho data while monitoring breathing, we demonstrate that whole-brain BOLD signals in the resting state are often caused by changes in breathing that co-occur with head motion. These widespread respiratory fMRI signals cannot be isolated from neurobiological signals by multiecho techniques because they occur via the same BOLD mechanism. Respiratory signals must therefore be removed by some other technique to isolate neurobiological covariance in fMRI time series. Several methods for removing global artifacts are demonstrated and compared, and were found to yield fMRI time series essentially free of motion-related influences. These results identify two kinds of motion-associated fMRI variance, with different physical mechanisms and spatial profiles, each of which strongly and differentially influences functional connectivity patterns. Distance-dependent patterns in covariance are nearly entirely attributable to non-BOLD artifacts.


Assuntos
Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Movimento (Física) , Respiração , Artefatos , Encéfalo/fisiologia , Estudos de Coortes , Humanos , Técnica de Subtração
10.
J Digit Imaging ; 34(2): 357-361, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33604806

RESUMO

Subtraction ictal single-photon emission computed tomography (SPECT) coregistered to MRI (SISCOM) is a well-established technique for quantitative analysis of ictal vs interictal SPECT images that can contribute to the identification of the seizure onset zone in patients with drug-resistant epilepsy. However, there is presently a lack of user-friendly free and open-source software to compute SISCOM results from raw SPECT and MRI images. We aimed to develop a simple graphical desktop application for computing SISCOM. MNI SISCOM is a new free and open-source software application for computing SISCOM and producing practical MRI/SPECT/SISCOM image panels for review and reporting. The graphical interface allows any user to quickly and easily obtain SISCOM images with minimal user interaction. Additionally, MNI SISCOM provides command line and Python interfaces for users who would like to integrate these features into their own scripts and pipelines. MNI SISCOM is freely available for download from: https://github.com/jeremymoreau/mnisiscom .


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada de Emissão de Fóton Único , Encéfalo/diagnóstico por imagem , Eletroencefalografia , Humanos , Técnica de Subtração , Tomografia Computadorizada por Raios X
11.
J Synchrotron Radiat ; 27(Pt 6): 1734-1740, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33147202

RESUMO

Spectral K-edge subtraction imaging and wide-field energy-dispersive X-ray absorption spectroscopy imaging are novel, related, synchrotron imaging techniques for element absorption contrast imaging and element speciation imaging, respectively. These two techniques serve different goals but share the same X-ray optics principles with a bent Laue type monochromator and the same data processing algorithms. As there is a growing interest to implement these novel techniques in synchrotron facilities, Python-based software has been developed to automate the data processing procedures for both techniques. In this paper, the concept of the essential data processing algorithms are explained, the workflow of the software is described, and the main features and some related utilities are introduced.


Assuntos
Algoritmos , Processamento de Sinais Assistido por Computador/instrumentação , Análise Espectral/métodos , Doses de Radiação , Razão Sinal-Ruído , Software , Técnica de Subtração , Síncrotrons , Raios X
12.
Eur Radiol ; 30(6): 3198-3209, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32048038

RESUMO

OBJECTIVES: The diagnostic reading of follow-up low-dose whole-body computed tomography (WBCT) examinations in patients with multiple myeloma (MM) is a demanding process. This study aimed to evaluate the diagnostic accuracy and benefit of a novel software program providing rapid-subtraction maps for bone lesion change detection. METHODS: Sixty patients (66 years ± 10 years) receiving 120 WBCT examinations for follow-up evaluation of MM bone disease were identified from our imaging archive. The median follow-up time was 292 days (range 200-641 days). Subtraction maps were calculated from 2-mm CT images using a nonlinear deformation algorithm. Reading time, correctly assessed lesions, and disease classification were compared to a standard reading software program. De novo clinical reading by a senior radiologist served as the reference standard. Statistics included Wilcoxon rank-sum test, Cohen's kappa coefficient, and calculation of sensitivity, specificity, positive/negative predictive value, and accuracy. RESULTS: Calculation time for subtraction maps was 84 s ± 24 s. Both readers reported exams faster using subtraction maps (reader A, 438 s ± 133 s; reader B, 1049 s ± 438 s) compared to PACS software (reader A, 534 s ± 156 s; reader B, 1486 s ± 587 s; p < 0.01). The course of disease was correctly classified by both methods in all patients. Sensitivity for lesion detection in subtraction maps/conventional reading was 92%/80% for reader A and 88%/76% for reader B. Specificity was 98%/100% for reader A and 95%/96% for reader B. CONCLUSION: A software program for the rapid-subtraction map calculation of follow-up WBCT scans has been successfully tested and seems suited for application in clinical routine. Subtraction maps significantly facilitated reading of WBCTs by reducing reading time and increasing sensitivity. KEY POINTS: • A novel algorithm has been successfully applied to generate motion-corrected bone subtraction maps of whole-body low-dose CT scans in less than 2 min. • Motion-corrected bone subtraction maps significantly facilitate the reading of follow-up whole-body low-dose CT scans in multiple myeloma by reducing reading time and increasing sensitivity.


Assuntos
Mieloma Múltiplo/diagnóstico por imagem , Software , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Idoso , Algoritmos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
AJR Am J Roentgenol ; 214(1): 72-80, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31573851

RESUMO

OBJECTIVE. The purpose of this study is to validate the use of subtraction images derived from gadoxetic acid-enhanced MRI for observation of washout and enhancing capsule in the diagnosis of hepatocellular carcinoma (HCC). MATERIALS AND METHODS. For 120 histologically verified HCCs in 115 high-risk patients, the presence of washout and enhancing capsule in the portal venous phase (PVP) on conventional MR images with and without corresponding subtraction images was determined by two independent observers. The incremental value of subtraction imaging in upgrading the categories outlined in the Liver Imaging Reporting and Data System (LI-RADS) version 2018 for the diagnosis of HCC was analyzed for different subgroups of patients classified on the basis of lesion size (< 10 mm, 10-19 mm, ≥ 20 mm), unenhanced T1-weighted signal intensity, and arterial phase hyperenhancement (APHE) of the lesions. RESULTS. When conventional PVP images were compared with the combination of conventional and subtraction PVP images, only T1-weighted isointensity or hyperintensity significantly increased the detection of washout (eight vs 15 of 18 lesions; p = 0.0233). Detection of enhancing capsule was significantly increased (p < 0.05) regardless of various factors, except for a lesion size of less than 2 cm (five vs nine of 36 lesions; p = 0.1336). Two lesions (one LI-RADS category 3 lesion and one LI-RADS category 4 lesion) with APHE were upgraded to category 5 on the basis of a review of PVP subtraction images. CONCLUSION. PVP subtraction imaging during gadoxetic acid-enhanced MRI can upgrade LI-RADS categories for the diagnosis of HCC because of its superior ability in depicting enhancing capsule and the incremental benefit of showing washout.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Veia Porta/diagnóstico por imagem , Técnica de Subtração , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa , Estudos Retrospectivos
14.
Echocardiography ; 37(4): 497-504, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32212390

RESUMO

AIM: To explore the feasibility and value of transthoracic echocardiography (TTE) postprocessing subtraction technique in the detection of a stent in the coronary artery. METHOD: Transthoracic echocardiography was used to examine 46 coronary artery stents in 30 patients by two-dimensional ultrasound postprocessing subtraction technique. The shape of each stent and its flow patency were observed. The patency was assessed according to blood flow and mosaic flow in the stent. Then, the results were compared with those of percutaneous coronary intervention (PCI) records and coronary angiography (CAG). RESULTS: Transthoracic echocardiography detected 36 stents among 46 stents (two in the LMCA, 23 in the LAD, seven in the RCA, and two in the LCX); the detection rate was 78.3%. The average length of the stents was 21.8 ± 4.1 mm, and the average diameter was 2.4 ± 0.5 mm; both are shorter than those from PCI records (P < .001). Of the 36 stents, blood flow could be observed in 27. Compared with the results of CAG, TTE had 75% feasibility and 92.6% accuracy in detecting flow patency in the stents. CONCLUSION: Transthoracic echocardiography postprocessing subtraction technique could be a noninvasive method for detecting a coronary artery stent and, although the measurements of stent length and diameter were shorter than those of PCI records, an accurate detection of flow patency in the stents was achieved.


Assuntos
Vasos Coronários , Intervenção Coronária Percutânea , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Ecocardiografia , Humanos , Stents , Técnica de Subtração
15.
Radiol Med ; 125(1): 1-6, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31562581

RESUMO

PURPOSE: To evaluate the influence of fat deposition on T1 relaxation time of pancreatic parenchyma using dual-flip-angle T1 mapping with and without fat suppression. METHODS: Forty-five patients who underwent abdominal MR imaging including T1 mapping with dual-flip-angle method on 3T MRI were included. We measured T1 relaxation time of pancreatic parenchyma on the T1 map images with and without fat suppression. T1 relaxation time of bone marrow was also measured as a reference organ with abundant fat deposition. Fat signal fraction (FSF) was also measured at the same location as T1 map images. Then, the correlation between T1 relaxation time and FSF was assessed. RESULTS: T1 relaxation times of pancreatic parenchyma and bone marrow on the T1 map images without fat suppression showed significantly negative correlation with FSF (pancreas, r = - 0.394, P = 0.007; bone marrow, r = - 0.550, P < 0.001), while there were no significant correlations between them on the T1 map images with fat suppression. On the T1 map images without fat suppression, T1 relaxation times of pancreatic parenchyma as well as bone marrow in patients with FSF ≥ 10% were significantly shorter than those in patients with FSF < 10% (pancreas, P = 0.041; bone marrow, P = 0.005). Conversely, on the T1 map images with fat suppression, no significant differences in T1 relaxation times were found between two groups. CONCLUSION: T1 relaxation time of the pancreas on T1 mapping was influenced by the presence of fat deposition. Therefore, fat suppression technique in T1 mapping will be essential for evaluating T1 relaxation time of pancreatic parenchyma.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pâncreas/diagnóstico por imagem , Pancreatopatias/diagnóstico por imagem , Técnica de Subtração , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Padrões de Referência , Estudos Retrospectivos , Fatores de Tempo
16.
J Digit Imaging ; 33(6): 1543-1553, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33025166

RESUMO

Temporal subtraction (TS) technique calculates a subtraction image between a pair of registered images acquired from the same patient at different times. Previous studies have shown that TS is effective for visualizing pathological changes over time; therefore, TS should be a useful tool for radiologists. However, artifacts caused by partial volume effects degrade the quality of thick-slice subtraction images, even with accurate image registration. Here, we propose a subtraction method for reducing artifacts in thick-slice images and discuss its implementation in high-speed processing. The proposed method is based on voxel matching, which reduces artifacts by considering gaps in discretized positions of two images in subtraction calculations. There are two different features between the proposed method and conventional voxel matching: (1) the size of a searching region to reduce artifacts is determined based on discretized position gaps between images and (2) the searching region is set on both images for symmetrical subtraction. The proposed method is implemented by adopting an accelerated subtraction calculation method that exploit the nature of liner interpolation for calculating the signal value at a point among discretized positions. We quantitatively evaluated the proposed method using synthetic data and qualitatively using clinical data interpreted by radiologists. The evaluation showed that the proposed method was superior to conventional methods. Moreover, the processing speed using the proposed method was almost unchanged from that of the conventional methods. The results indicate that the proposed method can improve the quality of subtraction images acquired from thick-slice images.


Assuntos
Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Humanos , Radiologistas , Técnica de Subtração
17.
J Hepatol ; 71(3): 534-542, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31108157

RESUMO

BACKGROUND & AIMS: Although gadoxetate disodium-enhanced magnetic resonance imaging (MRI) shows higher sensitivity for diagnosing hepatocellular carcinoma (HCC), its arterial-phase images may be unsatisfactory because of weak arterial enhancement. We investigated the clinical effectiveness of arterial subtraction images from gadoxetate disodium-enhanced MRI for diagnosing early-stage HCC using the Liver Imaging Reporting and Data System (LI-RADS) v2018. METHODS: In 258 patients at risk of HCC who underwent gadoxetate disodium-enhanced MRI in 2016, a total of 372 hepatic nodules (273 HCCs, 18 other malignancies, and 81 benign nodules) of 3.0 cm or smaller were retrospectively analyzed. Final diagnosis was assessed histopathologically or clinically (marginal recurrence after treatment or change in lesion size on follow-up imaging). The detection rate for arterial hyperenhancement was compared between ordinary arterial-phase and arterial subtraction images, and the benefit of arterial subtraction images in diagnosing HCC using LI-RADS was assessed. RESULTS: Arterial subtraction images had a significantly higher detection rate for arterial hyperenhancement than ordinary arterial-phase images, both for all hepatic nodules (72.3% vs. 62.4%, p <0.001) and HCCs (91.9% vs. 80.6%, p <0.001). Compared with ordinary arterial-phase images, arterial subtraction images significantly increased the sensitivity of LI-RADS category 5 for diagnosis of HCC (64.1% [173/270] vs. 55.9% [151/270], p <0.001), without significantly decreasing specificity (92.9% [91/98] vs. 94.9% [93/98], p = 0.155). For histopathologically confirmed lesions, arterial subtraction images significantly increased sensitivity to 68.8% (128/186) from the 61.3% (114/186) of ordinary arterial-phase images (p <0.001), with a minimal decrease in specificity to 84.8% (39/46) from 89.1% (41/46) (p = 0.151). CONCLUSIONS: Arterial subtraction images of gadoxetate disodium-enhanced MRI can significantly improve the sensitivity of early-stage HCC diagnosis using LI-RADS, without a significant decrease in specificity. LAY SUMMARY: Gadoxetate disodium-enhanced magnetic resonance imaging is an imaging technique with a high sensitivity for the diagnosis of hepatocellular carcinoma. However, arterial-phase images may be unsatisfactory because of weak arterial enhancement. We found that using arterial subtraction images led to clinically meaningful improvements in the diagnosis of early-stage hepatocellular carcinoma.


Assuntos
Artérias/diagnóstico por imagem , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Técnica de Subtração , Adulto , Idoso , Idoso de 80 Anos ou mais , Confiabilidade dos Dados , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias , Estudos Retrospectivos , Sensibilidade e Especificidade
18.
Osteoporos Int ; 30(5): 1051-1057, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30706095

RESUMO

Tc99m-sestamibi dual-time imaging is a standard tool for localization of adenomas/hyperplasia in hyperparathyroidism. We investigated the degree and causes of localization failure among different types of hyperparathyroidism. Pre-operative parathyroid hormone levels and size of the gland were major determinants of Tc99m-sestamibi positivity; 123I scan may be helpful in localization failures. INTRODUCTION: Tc99m-sestamibi dual-time imaging is a standard tool for localization of adenomas/hyperplasia in hyperparathyroidism. However, parathyroid adenomas/hyperplasia has been reported to washout as fast as normal thyroid tissue ("rapid washout") which may lead to diagnostic failure. We aimed to evaluate the determinants of rapid washout and to determine the role of subtraction imaging for detection of parathyroid adenomas/hyperplasia with rapid washout. METHODS: Retrospective analysis of patients with hyperparathyroidism who have undergone Tc99m-sestamibi dual-time imaging and parathyroid surgery. Rapid washout was correlated to the type of hyperparathyroidism in surgically confirmed cases. Biochemical and pathological data were reviewed. RESULTS: A total of 135 hyperparathyroidism patients met the inclusion criteria. Ninety-six (72%), 29 (21%), and 10 (7%) had primary, secondary, and tertiary hyperparathyroidisms, respectively. Rapid washout was identified in 28/87 glands (32%), 14/53 glands (26%), and 1/16 glands (6%) with primary, secondary, and tertiary hyperparathyroidisms, respectively. Glands that were positive on late-phase Tc99m-sestamibi scans were significantly large being 1.7 (IQR 1.4-2.3) vs. 1.45 (IQR 1-2) cm (p = 0.003). High parathyroid hormone levels (PTH) were associated with early-phase Tc99m-sestamibi positivity in both primary (p = 0.01) and secondary hyperparathyroidism (p = 0.03) but not with last phase (p = 0.11, p = 0.37, respectively). Correlative imaging with subtraction scintigraphy was positive in 14/16 (87.5%) parathyroid adenomas. CONCLUSION: Pre-operative PTH levels and size of the gland were major determinants of Tc99m-sestamibi positivity on early-phase Tc99m-sestamibi scans, whereas size is an independent predictor of late-phase Tc99m-sestamibi positivity. Subtraction scintigraphy might be a useful tool in suspected cases of rapid washout adenomas/hyperplasia.


Assuntos
Adenoma/diagnóstico por imagem , Hiperparatireoidismo Primário/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Adenoma/complicações , Adulto , Idoso , Feminino , Humanos , Hiperparatireoidismo Primário/etiologia , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Hormônio Paratireóideo/sangue , Neoplasias das Paratireoides/complicações , Cintilografia/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Técnica de Subtração , Tecnécio Tc 99m Sestamibi
19.
Eur Radiol ; 29(2): 759-769, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30062525

RESUMO

OBJECTIVE: To assess whether temporal subtraction (TS) images of brain CT improve the detection of suspected brain infarctions. METHODS: Study protocols were approved by our institutional review board, and informed consent was waived because of the retrospective nature of this study. Forty-two sets of brain CT images of 41 patients, each consisting of a pair of brain CT images scanned at two time points (previous and current) between January 2011 and November 2016, were collected for an observer performance study. The 42 sets consisted of 23 cases with a total of 77 newly developed brain infarcts or hyperdense artery signs confirmed by two radiologists who referred to additional clinical information and 19 negative control cases. To create TS images, the previous images were registered to the current images by partly using a non-rigid registration algorithm and then subtracted. Fourteen radiologists independently interpreted the images to identify the lesions with and without TS images with an interval of over 4 weeks. A figure of merit (FOM) was calculated along with the jackknife alternative free-response receiver-operating characteristic analysis. Sensitivity, number of false positives per case (FPC) and reading time were analyzed by the Wilcoxon signed-rank test. RESULTS: The mean FOM increased from 0.528 to 0.737 with TS images (p < 0.0001). The mean sensitivity and FPC improved from 26.5% and 0.243 to 56.0% and 0.153 (p < 0.0001 and p = 0.239), respectively. The mean reading time was 173 s without TS and 170 s with TS (p = 0.925). CONCLUSION: The detectability of suspected brain infarctions was significantly improved with TS CT images. KEY POINTS: • Although it is established that MRI is superior to CT in the detection of strokes, the first choice of modality for suspected stroke patients is often CT. • An observer performance study with 14 radiologists was performed to evaluate whether temporal subtraction images derived from a non-rigid transformation algorithm can significantly improve the detectability of newly developed brain infarcts on CT. • Temporal subtraction images were shown to significantly improve the detectability of newly developed brain infarcts on CT.


Assuntos
Infarto Encefálico/diagnóstico por imagem , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Eur Radiol ; 29(12): 6439-6442, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31273458

RESUMO

OBJECTIVE: Temporal subtraction of CT (TS) images improves detection of newly developed bone metastases (BM). We sought to determine whether TS improves detection of BM by radiology residents as well. METHODS: We performed an observer study using a previously reported dataset, consisting of 60 oncology patients, each with previous and current CT images. TS images were calculated using in-house software. Four residents independently interpreted twice the 60 sets of CT images, without and with TS. They identified BM by marking suspicious lesions likely to be BM. Lesion-based sensitivity and number of false positives per patient were calculated. Figure-of-merit (FOM) was calculated. Detectability of BM, with and without TS, was compared between radiology residents and board-certified radiologists, as published previously. RESULTS: FOM of residents significantly improved by implementing TS (p value < 0.0001). Lesion-based sensitivity, false positives per patients, and FOM were 40.8%, 0.121, and 0.657, respectively, without TS, and 58.1%, 0.0958, and 0.796, respectively, with TS. These findings were comparable with the previously published values for board-certified radiologists without TS (58.0%, 0.19, and 0.758, respectively). CONCLUSION: The detectability of BM by residents improved markedly by implementing TS and reached that of board-certified radiologists without TS. KEY POINTS: • Detectability of bone metastases on CT by residents improved significantly when using temporal subtraction of CT (TS). • Detections by residents with TS and board-certified radiologists without TS were comparable. • TS is useful for residents as it is for board-certified radiologists.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Competência Clínica/estatística & dados numéricos , Interpretação de Imagem Assistida por Computador/métodos , Radiologia/educação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Internato e Residência , Sensibilidade e Especificidade , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa