Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Eur J Orthod ; 40(1): 65-73, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29016734

RESUMO

Background: Examination with Cone Beam CT (CBCT) is common for localizing maxillary canines with eruption disturbance. The benefits and costs of these examinations are unclear. Objectives: To measure: 1. the proportion of orthodontists' treatment decisions that were different based on intraoral and panoramic radiography (M1) compared with CBCT and panoramic radiography (M2); and 2. the costs of producing different treatment plans, regarding patients with maxillary canines with eruption disturbance. Subjects and methods: Orthodontists participated in a web-based survey and were randomly assigned to denote treatment decisions and the level of confidence in this decision for four patient cases presented with M1 or M2 at two occasions for the same patient case. Results: One hundred and twelve orthodontists made 445 assessments based on M1 and M2, respectively. Twenty-four per cent of the treatment decisions were different depending on which method the raters had access to, whereof one case differed significantly from all other cases. The mean total cost per examination was €99.84 using M1 and €134.37 using M2, resulting in an incremental cost per examination of €34.53 for M2. Limitations: Benefits in terms of number of different treatment decisions must be considered as an intermediate outcome for the effectiveness of a diagnostic method and should be interpreted with caution. Conclusions: For the patient cases presented in this study, most treatment decisions were the same irrespective of radiological method. Accordingly, this study does not support routine use of CBCT regarding patients with maxillary canine with eruption disturbance.


Assuntos
Dente Canino/diagnóstico por imagem , Custos de Cuidados de Saúde/estatística & dados numéricos , Dente Impactado/diagnóstico por imagem , Adolescente , Tomada de Decisão Clínica , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/métodos , Dente Canino/cirurgia , Feminino , Humanos , Masculino , Maxila/diagnóstico por imagem , Maxila/cirurgia , Planejamento de Assistência ao Paciente , Radiografia Panorâmica/economia , Radiografia Panorâmica/métodos , Reabsorção da Raiz , Suécia , Dente Impactado/cirurgia
2.
BMC Oral Health ; 18(1): 88, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29764458

RESUMO

BACKGROUND: In implant dentistry, three-dimensional (3D) imaging can be realised by dental cone beam computed tomography (CBCT), offering volumetric data on jaw bones and teeth with relatively low radiation doses and costs. The latter may explain why the market has been steadily growing since the first dental CBCT system appeared two decades ago. More than 85 different CBCT devices are currently available and this exponential growth has created a gap between scientific evidence and existing CBCT machines. Indeed, research for one CBCT machine cannot be automatically applied to other systems. METHODS: Supported by a narrative review, recommendations for justified and optimized CBCT imaging in oral implant dentistry are provided. RESULTS: The huge range in dose and diagnostic image quality requires further optimization and justification prior to clinical use. Yet, indications in implant dentistry may go beyond diagnostics. In fact, the inherent 3D datasets may further allow surgical planning and transfer to surgery via 3D printing or navigation. Nonetheless, effective radiation doses of distinct dental CBCT machines and protocols may largely vary with equivalent doses ranging between 2 to 200 panoramic radiographs, even for similar indications. Likewise, such variation is also noticed for diagnostic image quality, which reveals a massive variability amongst CBCT technologies and exposure protocols. For anatomical model making, the so-called segmentation accuracy may reach up to 200 µm, but considering wide variations in machine performance, larger inaccuracies may apply. This also holds true for linear measures, with accuracies of 200 µm being feasible, while sometimes fivefold inaccuracy levels may be reached. Diagnostic image quality may also be dramatically hampered by patient factors, such as motion and metal artefacts. Apart from radiodiagnostic possibilities, CBCT may offer a huge therapeutic potential, related to surgical guides and further prosthetic rehabilitation. Those additional opportunities may surely clarify part of the success of using CBCT for presurgical implant planning and its transfer to surgery and prosthetic solutions. CONCLUSIONS: Hence, dental CBCT could be justified for presurgical diagnosis, preoperative planning and peroperative transfer for oral implant rehabilitation, whilst striving for optimisation of CBCT based machine-dependent, patient-specific and indication-oriented variables.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Implantação Dentária , Imageamento Tridimensional , Planejamento de Assistência ao Paciente , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/normas , Custos e Análise de Custo , Humanos , Modelos Dentários , Cuidados Pós-Operatórios , Guias de Prática Clínica como Assunto , Cuidados Pré-Operatórios , Doses de Radiação
3.
J Oral Maxillofac Surg ; 74(4): 668-79, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26611374

RESUMO

PURPOSE: The American Association of Oral and Maxillofacial Surgeons appointed a task force to study the indications, safety, and clinical practice patterns of cone-beam computed tomography (CBCT) in oral and maxillofacial surgery (OMS). The charge was to review the published applications of CBCT in OMS, identify the current position of academic thought leaders in the field, and research the adoption and usage of the technology at the clinical practitioner level. MATERIALS AND METHODS: This study reviewed the CBCT world literature and summarized published indications for the modality. A nationwide survey of academic thought leaders and practicing oral and maxillofacial surgeons was compiled to determine how the modality is currently being used and adopted by institutions and practices. RESULTS: This report summarizes published applications of CBCT that have been vetted by the academic and practicing OMS community to define current indications. The parameters of patient safety, radiation exposure, accreditation, and legal issues are reviewed. An overview of third-party adoption of CBCT is presented. CONCLUSION: CBCT is displacing 2-dimensional imaging in the published literature, academia, and private practice. Best practices support reading the entire scan volume with a written report defining results, patient exposure, and field of view. Issues of patient safety, ALARA ("as low as reasonably achievable"), accreditation, and the legal and regulatory environment are reviewed. Third-party patterns for reimbursements vary widely and seem to lack consistency. There is much confusion within the provider community about indications, authorizations, and payment policies. The current medical and dental indications for CBCT in the clinical practice of OMS are reviewed and an industry guideline is proposed. These guidelines offer a clear way of differentiating consensus medical indications and common dental uses for clinicians. This matrix should bring a predictable logic to third-party authorizations, billing, and predictable payments for this emerging technology in OMS.


Assuntos
Centros Médicos Acadêmicos/estatística & dados numéricos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Procedimentos Cirúrgicos Bucais/estatística & dados numéricos , Prática Profissional/estatística & dados numéricos , Cirurgia Bucal/estatística & dados numéricos , Centros Médicos Acadêmicos/legislação & jurisprudência , Acreditação , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/normas , Humanos , Reembolso de Seguro de Saúde/economia , Segurança do Paciente , Prática Profissional/legislação & jurisprudência , Doses de Radiação , Cirurgia Bucal/legislação & jurisprudência , Estados Unidos
4.
J Craniofac Surg ; 25(4): 1150-4, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24933305

RESUMO

PURPOSE: Computed tomography (CT) is currently the standard in postoperative evaluation of orbital wall fracture reconstruction, but cone beam computed tomography (CBCT) offers potential advantages including reduced radiation dose and cost. The purpose of this study is to examine objectively the image quality of CBCT in the postoperative evaluation of orbital fracture reconstruction, its radiation dose, and cost compared with CT. MATERIALS AND METHODS: Four consecutive patients with orbital wall fractures in whom surgery was indicated underwent orbital reconstruction with radio-opaque grafts (bone, titanium-reinforced polyethylene, and titanium plate) and were assessed postoperatively with orbital CBCT. CBCT was evaluated for its ability to provide objective information regarding the adequacy of orbital reconstruction, radiation dose, and cost. RESULTS: In all patients, CBCT was feasible and provided hard tissue image quality comparable to CT with significantly reduced radiation dose and cost. However, it has poorer soft tissue resolution, which limits its ability to identify the extraocular muscles, their relationship to the reconstructive graft, and potential muscle entrapment. CONCLUSIONS: CBCT is a viable alternative to CT in the routine postoperative evaluation of orbital fracture reconstruction. However, in the patient who develops gaze restriction postoperatively, conventional CT is preferred over CBCT for its superior soft tissue resolution to exclude extraocular muscle entrapment.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Fraturas Orbitárias/diagnóstico por imagem , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/normas , Estudos de Viabilidade , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Orbitárias/cirurgia , Período Pós-Operatório , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
5.
J Calif Dent Assoc ; 42(3): 173-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25080723

RESUMO

Evaluate the use of cone beam computed tomography among orthodontists in two areas of the Pacific Coast region via an electronic survey sent to the chairs of the orthodontic programs at the University of California, San Francisco, and A.T. Still University in Mesa, Ariz. The survey link was subsequently forwarded to each program's alumni. Overall, 85.7 percent of the orthodontists reported using CBCT scans. The scans were primarily used for impacted/supernumerary teeth and temporomandibular joint disorders analysis.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Ortodontia/estatística & dados numéricos , Arizona , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/instrumentação , Humanos , Imageamento Tridimensional/estatística & dados numéricos , Planejamento de Assistência ao Paciente , Projetos Piloto , Padrões de Prática Odontológica/estatística & dados numéricos , Prática Privada , Doses de Radiação , São Francisco , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Dente Impactado/diagnóstico por imagem , Dente Supranumerário/diagnóstico por imagem
6.
Clin Oral Implants Res ; 23(3): 351-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22092419

RESUMO

AIM: To assess the financial benefit of cone beam computed tomography (CBCT) for the treatment options of maxillary molars including periodontal surgery and extraction followed by implant placement. MATERIAL AND METHODS: Twelve patients with generalized chronic periodontitis were recruited, and CBCT was performed in maxillary molars (n = 22) with clinical furcation involvement and increased probing pocket depths. Treatment recommendations were either based on conventional periodontal diagnostics (clinical examinations and periapical radiographs), or based on the additional CBCT data. Clinical recommendations comprised a minimal (e.g. supportive periodontal treatment) and a maximal invasive therapy (e.g. extraction and implant placement), and these were compared with CBCT-based recommendations. According to the Swiss dental tariff structure, the probabilities of saving costs or time, and the numbers needed to treat were analysed with an empirical cumulative distribution function. RESULTS: Average cost reduction from CBCT amounted to CHF 915 ± 1470 and saved 136 ± 217 min. Greatest reductions were found with maximal invasive clinically based treatment decisions (CHF 1566 ± 1840), particularly for second molars (CHF 2485 ± 2226). To compensate CBCT costs, 1.7 subjects were needed to treat to at least break even. CONCLUSIONS: Data from CBCT facilitated a reduction in treatment costs and time for periodontally involved maxillary molars in Switzerland. Based on these cost analyses, however, CBCT as additional diagnostic measure is justified only when more invasive therapies are planned.


Assuntos
Tomografia Computadorizada de Feixe Cônico/economia , Defeitos da Furca/diagnóstico por imagem , Defeitos da Furca/cirurgia , Imageamento Tridimensional/economia , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Projetos Piloto , Interpretação de Imagem Radiográfica Assistida por Computador , Retalhos Cirúrgicos , Suíça
7.
Dent Today ; 31(9): 94, 96-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23019853

RESUMO

As a profession, we must remember that tooth replacement is not a luxury; it is often a necessity for health reasons. Although bone augmentation and CBCT and expensive surgical guides are often indicated for complex cases, they are being overused. Simple or straightforward implant cases, when there is sufficient natural bone for narrow or shorter implant, can be predictable performed by well-trained GPs and other trained specialists. Complex cases requiring bone augmentation and other complexities as described herein, should be referred to a surgical specialist. Implant courses and curricula have to be based on the level of complexity of implant surgery that each clinician wishes to provide to his or her patients. Using a "logical approach" to implant dentistry keeps cases simple or straightforward, and more accessible to patients by the correct use of narrow and shorter implants.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Planejamento de Prótese Dentária , Odontologia Baseada em Evidências , Perda do Osso Alveolar/reabilitação , Aumento do Rebordo Alveolar/economia , Aumento do Rebordo Alveolar/estatística & dados numéricos , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Custos e Análise de Custo , Implantação Dentária Endóssea/economia , Implantes Dentários/economia , Odontologia Geral , Humanos , Encaminhamento e Consulta
8.
J Calif Dent Assoc ; 37(9): 653-62, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19810647

RESUMO

Until the recent introduction of cone beam computed tomography scanners, standard 2-D imaging provided a moderate contribution to overall treatment planning when considering the diagnostic potential, costs of study, and risks to the patient. Cone beam computed tomography-dedicated maxillofacial imaging scanners provide broader imaging tools for anatomic assessment and have become widely available. This article discusses the uses and benefits of 3-D imaging, as well as the impact on the standard of care.


Assuntos
Tomografia Computadorizada de Feixe Cônico/normas , Arcada Edêntula/diagnóstico por imagem , Radiografia Dentária/métodos , Gestão de Riscos , Recusa do Paciente ao Tratamento/legislação & jurisprudência , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/instrumentação , Implantação Dentária Endóssea , Diagnóstico Bucal/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Consentimento Livre e Esclarecido , Ortodontia , Garantia da Qualidade dos Cuidados de Saúde , Radiografia Dentária/normas , Fatores Socioeconômicos , Software , Extração Dentária , Dente Impactado/diagnóstico por imagem
10.
Dent Clin North Am ; 62(3): 361-391, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29903556

RESUMO

In the last several decades, the need for 3D images in dentistry have developed. Computerized tomography was first introduced mainly with the advent of implantology, but its use remained limited to a small number of specialists, due to its indications, access and dose radiation. In the late 90's, a new technology using a cone-shaped beam and a reciprocating detector, which rotates around the patient 360 degrees and acquires projected data in a single rotation, namely the cone beam computerized tomography (CBCT), invaded dentistry, making the perception of 3D easily acceptable to dentists and their patients.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radiografia Dentária , Artefatos , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/história , Tomografia Computadorizada de Feixe Cônico/métodos , Custos e Análise de Custo , Implantação Dentária Endóssea , Diagnóstico Bucal , Endodontia , História do Século XX , História do Século XXI , Humanos , Imageamento Tridimensional/economia , Imageamento Tridimensional/história , Imageamento Tridimensional/métodos , Ortodontia , Periodontia , Impressão Tridimensional , Intensificação de Imagem Radiográfica , Radiografia Dentária/efeitos adversos , Radiografia Dentária/economia , Radiografia Dentária/história , Radiografia Dentária/métodos , Tomografia Computadorizada por Raios X
12.
Health Devices ; 36(11): 362-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18543531

RESUMO

This article provides opinions and predictions about an emerging technology-256-slice wide-detector computed tomography-to help healthcare facilities decide whether the technology is worth tracking and when it might be ready for adoption. We believe 256-slice CT is worth monitoring based on its predicted clinical and business impact. We consider it unlikely, however, that more than a few select facilities will begin adopting this technology within the next three years.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Avaliação da Tecnologia Biomédica , Tomografia Computadorizada de Feixe Cônico/economia , Relação Dose-Resposta à Radiação , Coração/diagnóstico por imagem , Perfusão
13.
J Med Imaging Radiat Oncol ; 61(5): 600-606, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28345214

RESUMO

INTRODUCTION: This study examines the effects of the new Medicare Benefits Schedule (MBS) operating from 1st November 2014 on the number of Medicare rebated panoramic radiography (PR) and cone beam computed tomography (CBCT) scans. METHODS: Data for rebated PR and CBCT scans were extracted from Medicare Australia Statistics online for four 12-month periods: November 2011-October 2012, November 2012-October 2013, November 2013-October 2014 and December 2014-November 2015. RESULTS: There was a reduction in the number of CBCT scans rebated across Australia under the new MBS. Nationally, December 2014-November 2015 showed a 65.3% reduction in the number of CBCT scans when compared to the peak in the previous 12 months under the old MBS. The number of rebated PR scans remained constant. CONCLUSION: The new MBS implemented on 1st November 2014 resulted in a reduction in the number of rebated CBCT scans, but had no effect on rebated PR scans. Overall, there has been considerable cost savings for Medicare due to the change in MBS. Additionally, the reduction in the number of rebated CBCT scans has resulted in a substantial reduction in the ionising radiation load to the Australian community as a whole, but especially the younger age groups.


Assuntos
Tomografia Computadorizada de Feixe Cônico/economia , Programas Nacionais de Saúde/economia , Radiografia Panorâmica/economia , Austrália , Feminino , Humanos , Masculino , Estados Unidos
14.
PLoS One ; 12(4): e0175907, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28419147

RESUMO

PURPOSE: To evaluate the usefulness of cone-beam computed tomography with automated bone subtraction (CBCT-ABS) in the preoperative embolization of hypervascular tumors located in the pelvic bone. MATERIALS AND METHODS: This retrospective study included 26 patients with pelvic bone tumors who underwent preoperative embolization between January 2014 and October 2016. A CBCT-ABS scan was taken in a total of 17 patients (CBCT-ABS group), and only a series of digital subtraction angiographies (DSAs) was taken in the remaining 9 patients (DSA group). The percent devascularization, number of angiographic runs, total dose-area product (DAP), fluoroscopy time, interventional procedure time, operative time, and estimated blood loss were compared between the two groups using Mann-Whitney test. RESULTS: The percent devascularization, interventional procedure time, fluoroscopy time, operative time, and estimated blood loss were not statistically different between the two groups (p > 0.05). On the other hand, the number of angiographic runs in the CBCT-ABS group was significantly lower than that in the DSA group (p = 0.029). The total DAP of the CBCT-ABS group (mean, 17700.7 µGym2) was higher than that of the DSA group (mean, 8939.4 µGym2) (p = 0.002). CONCLUSIONS: The use of CBCT-ABS during the preoperative embolization of pelvic bone tumors significantly reduces the number of angiographic runs at the cost of an increased radiation dose.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Ossos Pélvicos/diagnóstico por imagem , Neoplasias Pélvicas/diagnóstico por imagem , Adulto , Idoso , Neoplasias Ósseas/terapia , Tomografia Computadorizada de Feixe Cônico/economia , Embolização Terapêutica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pélvicas/terapia , Estudos Retrospectivos
17.
PLoS One ; 11(6): e0156976, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27300554

RESUMO

In this paper, we propose an automatic method of synthesizing panoramic radiographs from dental cone beam computed tomography (CBCT) data for directly observing the whole dentition without the superimposition of other structures. This method consists of three major steps. First, the dental arch curve is generated from the maximum intensity projection (MIP) of 3D CBCT data. Then, based on this curve, the long axial curves of the upper and lower teeth are extracted to create a 3D panoramic curved surface describing the whole dentition. Finally, the panoramic radiograph is synthesized by developing this 3D surface. Both open-bite shaped and closed-bite shaped dental CBCT datasets were applied in this study, and the resulting images were analyzed to evaluate the effectiveness of this method. With the proposed method, a single-slice panoramic radiograph can clearly and completely show the whole dentition without the blur and superimposition of other dental structures. Moreover, thickened panoramic radiographs can also be synthesized with increased slice thickness to show more features, such as the mandibular nerve canal. One feature of the proposed method is that it is automatically performed without human intervention. Another feature of the proposed method is that it requires thinner panoramic radiographs to show the whole dentition than those produced by other existing methods, which contributes to the clarity of the anatomical structures, including the enamel, dentine and pulp. In addition, this method can rapidly process common dental CBCT data. The speed and image quality of this method make it an attractive option for observing the whole dentition in a clinical setting.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Arco Dental/diagnóstico por imagem , Dentição , Radiografia Panorâmica/métodos , Tomografia Computadorizada de Feixe Cônico/economia , Arco Dental/anatomia & histologia , Humanos , Processamento de Imagem Assistida por Computador/economia , Processamento de Imagem Assistida por Computador/métodos , Radiografia Panorâmica/economia , Fatores de Tempo
18.
Spine J ; 16(1): 23-31, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26456854

RESUMO

BACKGROUND CONTEXT: Pedicle screws are routinely used in contemporary spinal surgery. Screw misplacement may be asymptomatic but is also correlated with potential adverse events. Computer-assisted surgery (CAS) has been associated with improved screw placement accuracy rates. However, this technology has substantial acquisition and maintenance costs. Despite its increasing usage, no rigorous full economic evaluation comparing this technology to current standard of care has been reported. PURPOSE: Medical costs are exploding in an unsustainable way. Health economic theory requires that medical equipment costs be compared with expected benefits. To answer this question for computer-assisted spinal surgery, we present an economic evaluation looking specifically at symptomatic misplaced screws leading to reoperation secondary to neurologic deficits or biomechanical concerns. STUDY DESIGN/SETTING: The study design was an observational case-control study from prospectively collected data of consecutive patients treated with the aid of CAS (treatment group) compared with a matched historical cohort of patients treated with conventional fluoroscopy (control group). PATIENT SAMPLE: The patient sample consisted of consecutive patients treated surgically at a quaternary academic center. OUTCOME MEASURES: The primary effectiveness measure studied was the number of reoperations for misplaced screws within 1 year of the index surgery. Secondary outcome measures included were total adverse event rate and postoperative computed tomography usage for pedicle screw examination. METHODS: A patient-level data cost-effectiveness analysis from the hospital perspective was conducted to determine the value of a navigation system coupled with intraoperative 3-D imaging (O-arm Imaging and the StealthStation S7 Navigation Systems, Medtronic, Louisville, CO, USA) in adult spinal surgery. The capital costs for both alternatives were reported as equivalent annual costs based on the annuitization of capital expenditures method using a 3% discount rate and a 7-year amortization period. Annual maintenance costs were also added. Finally, reoperation costs using a micro-costing approach were calculated for both groups. An incremental cost-effectiveness ratio was calculated and reported as cost per reoperation avoided. Based on reoperation costs in Canada and in the United States, a minimal caseload was calculated for the more expensive alternative to be cost saving. Sensitivity analyses were also conducted. RESULTS: A total of 5,132 pedicle screws were inserted in 502 patients during the study period: 2,682 screws in 253 patients in the treatment group and 2,450 screws in 249 patients in the control group. Overall accuracy rates were 95.2% for the treatment group and 86.9% for the control group. Within 1 year post treatment, two patients (0.8%) required a revision surgery in the treatment group compared with 15 patients (6%) in the control group. An incremental cost-effectiveness ratio of $15,961 per reoperation avoided was calculated for the CAS group. Based on a reoperation cost of $12,618, this new technology becomes cost saving for centers performing more than 254 instrumented spinal procedures per year. CONCLUSIONS: Computer-assisted spinal surgery has the potential to reduce reoperation rates and thus to have serious cost-effectiveness and policy implications. High acquisition and maintenance costs of this technology can be offset by equally high reoperation costs. Our cost-effectiveness analysis showed that for high-volume centers with a similar case complexity to the studied population, this technology is economically justified.


Assuntos
Tomografia Computadorizada de Feixe Cônico/economia , Análise Custo-Benefício , Fluoroscopia/economia , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Fluoroscopia/métodos , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Procedimentos Neurocirúrgicos/economia , Parafusos Pediculares/efeitos adversos , Parafusos Pediculares/economia , Reoperação/economia , Reoperação/estatística & dados numéricos , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/economia
19.
Dentomaxillofac Radiol ; 44(6): 20140406, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25785820

RESUMO

OBJECTIVES: This epidemiological study aimed to analyse economical and societal consequences in Denmark if CBCT is used routinely as a diagnostic method before removal of the mandibular third molar. Furthermore, the aim was to calculate the excess cancer incidence from this practice. METHODS: 17 representative dental clinics in the regions of Denmark were visited by two observers, who registered the total number of patients in each clinic, the number of removed mandibular third molars from patients' files together with the age and gender of these patients. The data were collected from 2008 to 2014. The total number of removed mandibular third molars in Denmark each year was derived from the collected data and information on patients' contacts with dentists from Statistics Denmark as a sum of contributions from each region. The contribution of a region was obtained as the number of removed mandibular third molars in the selected clinics in the region times the ratio of the number of patients in the selected clinics in the region to the total number of patients with contact to a general practitioner in the region in 2011. Existing knowledge on the costs for panoramic and CBCT imaging was used to calculate total costs. The cancer incidence was calculated from lifetime attributable risk curves based on linear risk assumptions. RESULTS: The selected clinics included 109,686 patients, and 1369 mandibular third molars had been surgically removed. Using data from Statistics Denmark gave an estimated annual number of removed mandibular third molars of 36,882 at a total cost of €6,633,400. The additional cancer incidence was estimated to be approximately 0.46 per year. CONCLUSIONS: The data should be used in a cost-effectiveness analysis of the clinical efficacy of CBCT imaging before removal of mandibular third molars.


Assuntos
Tomografia Computadorizada de Feixe Cônico/economia , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Adulto , Tomografia Computadorizada de Feixe Cônico/efeitos adversos , Dinamarca/epidemiologia , Relação Dose-Resposta à Radiação , Feminino , Humanos , Incidência , Masculino , Neoplasias Induzidas por Radiação/epidemiologia , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade
20.
Handchir Mikrochir Plast Chir ; 47(1): 24-31, 2015 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-25706176

RESUMO

During the last decade, DVT (digital volume tomography) imaging has become a widely used standard technique in head and neck imaging. Lower radiation exposure compared to conventional computed tomography (MDCT) has been described. Recently, DVT has been developed as an extremity scanner and as such represents a new imaging technique for hand surgery. We here describe the first 24 months experience with this new imaging modality in hand and wrist imaging by presenting representative cases and by describing the technical background. Furthermore, the method's advantages and disadvantages are discussed with reference to the given literature.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Ossos da Mão/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/economia , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Fraturas Ósseas/diagnóstico por imagem , Traumatismos da Mão/diagnóstico por imagem , Humanos , Cobertura do Seguro/economia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Programas Nacionais de Saúde/economia , Posicionamento do Paciente , Doses de Radiação , Mecanismo de Reembolso/economia , Sensibilidade e Especificidade , Traumatismos do Punho/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa