Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216.925
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Nature ; 629(8013): 810-818, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38778234

RESUMO

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Assuntos
Velocidade do Fluxo Sanguíneo , Encéfalo , Circulação Cerebrovascular , Ultrassonografia , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Erros Médicos , Razão Sinal-Ruído , Pele , Crânio , Sonolência/fisiologia , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Adulto
2.
Nature ; 623(7985): 106-114, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37880365

RESUMO

Maturation of the human fetal brain should follow precisely scheduled structural growth and folding of the cerebral cortex for optimal postnatal function1. We present a normative digital atlas of fetal brain maturation based on a prospective international cohort of healthy pregnant women2, selected using World Health Organization recommendations for growth standards3. Their fetuses were accurately dated in the first trimester, with satisfactory growth and neurodevelopment from early pregnancy to 2 years of age4,5. The atlas was produced using 1,059 optimal quality, three-dimensional ultrasound brain volumes from 899 of the fetuses and an automated analysis pipeline6-8. The atlas corresponds structurally to published magnetic resonance images9, but with finer anatomical details in deep grey matter. The between-study site variability represented less than 8.0% of the total variance of all brain measures, supporting pooling data from the eight study sites to produce patterns of normative maturation. We have thereby generated an average representation of each cerebral hemisphere between 14 and 31 weeks' gestation with quantification of intracranial volume variability and growth patterns. Emergent asymmetries were detectable from as early as 14 weeks, with peak asymmetries in regions associated with language development and functional lateralization between 20 and 26 weeks' gestation. These patterns were validated in 1,487 three-dimensional brain volumes from 1,295 different fetuses in the same cohort. We provide a unique spatiotemporal benchmark of fetal brain maturation from a large cohort with normative postnatal growth and neurodevelopment.


Assuntos
Encéfalo , Desenvolvimento Fetal , Feto , Pré-Escolar , Feminino , Humanos , Gravidez , Encéfalo/anatomia & histologia , Encéfalo/embriologia , Encéfalo/crescimento & desenvolvimento , Feto/embriologia , Idade Gestacional , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/embriologia , Substância Cinzenta/crescimento & desenvolvimento , Voluntários Saudáveis , Internacionalidade , Imageamento por Ressonância Magnética , Tamanho do Órgão , Estudos Prospectivos , Organização Mundial da Saúde , Imageamento Tridimensional , Ultrassonografia
3.
PLoS Biol ; 22(6): e3002664, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38829885

RESUMO

Neuroscientists studying the neural correlates of mouse behavior often lack access to the brain-wide activity patterns elicited during a specific task of interest. Fortunately, large-scale imaging is becoming increasingly accessible thanks to modalities such as Ca2+ imaging and functional ultrasound (fUS). However, these and other techniques often involve challenging cranial window procedures and are difficult to combine with other neuroscience tools. We address this need with an open-source 3D-printable cranial implant-the COMBO (ChrOnic Multimodal imaging and Behavioral Observation) window. The COMBO window enables chronic imaging of large portions of the brain in head-fixed mice while preserving orofacial movements. We validate the COMBO window stability using both brain-wide fUS and multisite two-photon imaging. Moreover, we demonstrate how the COMBO window facilitates the combination of optogenetics, fUS, and electrophysiology in the same animals to study the effects of circuit perturbations at both the brain-wide and single-neuron level. Overall, the COMBO window provides a versatile solution for performing multimodal brain recordings in head-fixed mice.


Assuntos
Encéfalo , Optogenética , Animais , Camundongos , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Optogenética/métodos , Neurônios/fisiologia , Camundongos Endogâmicos C57BL , Crânio/fisiologia , Masculino , Comportamento Animal/fisiologia , Imagem Multimodal/métodos , Ultrassonografia/métodos , Impressão Tridimensional
4.
N Engl J Med ; 388(22): 2049-2057, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37256975

RESUMO

BACKGROUND: Data on whether ultrasonography for the initial diagnostic imaging of forearm fractures in children and adolescents is noninferior to radiography for subsequent physical function of the arm are limited. METHODS: In this open-label, multicenter, noninferiority, randomized trial in Australia, we recruited participants 5 to 15 years of age who presented to the emergency department with an isolated distal forearm injury, without a clinically visible deformity, in whom further evaluation with imaging was indicated. Participants were randomly assigned to initially undergo point-of-care ultrasonography or radiography, and were then followed for 8 weeks. The primary outcome was physical function of the affected arm at 4 weeks as assessed with the use of the validated Pediatric Upper Extremity Short Patient-Reported Outcomes Measurement Information System (PROMIS) score (range, 8 to 40, with higher scores indicating better function); the noninferiority margin was 5 points. RESULTS: A total of 270 participants were enrolled, with outcomes for 262 participants (97%) available at 4 weeks (with a window of ±3 days) as prespecified. PROMIS scores at 4 weeks in the ultrasonography group were noninferior to those in the radiography group (mean, 36.4 and 36.3 points, respectively; mean difference, 0.1 point; 95% confidence interval [CI], -1.3 to 1.4). Intention-to-treat analyses (in 266 participants with primary outcome data recorded at any time) produced similar results (mean difference, 0.1 point; 95% CI, -1.3 to 1.4). No clinically important fractures were missed, and there were no between-group differences in the occurrence of adverse events. CONCLUSIONS: In children and adolescents with a distal forearm injury, the use of ultrasonography as the initial diagnostic imaging method was noninferior to radiography with regard to the outcome of physical function of the arm at 4 weeks. (Funded by the Emergency Medicine Foundation and others; BUCKLED Australian New Zealand Clinical Trials Registry number, ACTRN12620000637943).


Assuntos
Traumatismos do Antebraço , Fraturas Ósseas , Fraturas do Punho , Adolescente , Criança , Humanos , Austrália , Traumatismos do Antebraço/diagnóstico por imagem , Fraturas Ósseas/diagnóstico por imagem , Radiografia , Ultrassonografia , Fraturas do Punho/diagnóstico por imagem , Pré-Escolar , Testes Imediatos
5.
N Engl J Med ; 388(16): 1501-1511, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-37075142

RESUMO

BACKGROUND: The use of cerebral oximetry monitoring in the care of extremely preterm infants is increasing. However, evidence that its use improves clinical outcomes is lacking. METHODS: In this randomized, phase 3 trial conducted at 70 sites in 17 countries, we assigned extremely preterm infants (gestational age, <28 weeks), within 6 hours after birth, to receive treatment guided by cerebral oximetry monitoring for the first 72 hours after birth or to receive usual care. The primary outcome was a composite of death or severe brain injury on cerebral ultrasonography at 36 weeks' postmenstrual age. Serious adverse events that were assessed were death, severe brain injury, bronchopulmonary dysplasia, retinopathy of prematurity, necrotizing enterocolitis, and late-onset sepsis. RESULTS: A total of 1601 infants underwent randomization and 1579 (98.6%) were evaluated for the primary outcome. At 36 weeks' postmenstrual age, death or severe brain injury had occurred in 272 of 772 infants (35.2%) in the cerebral oximetry group, as compared with 274 of 807 infants (34.0%) in the usual-care group (relative risk with cerebral oximetry, 1.03; 95% confidence interval, 0.90 to 1.18; P = 0.64). The incidence of serious adverse events did not differ between the two groups. CONCLUSIONS: In extremely preterm infants, treatment guided by cerebral oximetry monitoring for the first 72 hours after birth was not associated with a lower incidence of death or severe brain injury at 36 weeks' postmenstrual age than usual care. (Funded by the Elsass Foundation and others; SafeBoosC-III ClinicalTrials.gov number, NCT03770741.).


Assuntos
Lactente Extremamente Prematuro , Doenças do Prematuro , Oximetria , Humanos , Lactente , Recém-Nascido , Lesões Encefálicas/diagnóstico por imagem , Lesões Encefálicas/etiologia , Displasia Broncopulmonar/etiologia , Circulação Cerebrovascular , Doenças do Prematuro/diagnóstico , Doenças do Prematuro/mortalidade , Doenças do Prematuro/terapia , Oximetria/métodos , Cérebro , Ultrassonografia , Retinopatia da Prematuridade/etiologia , Enterocolite Necrosante/etiologia , Sepse Neonatal/etiologia
6.
Chem Rev ; 124(13): 8307-8472, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38924776

RESUMO

Due to the intrinsic non-invasive nature, cost-effectiveness, high safety, and real-time capabilities, besides diagnostic imaging, ultrasound as a typical mechanical wave has been extensively developed as a physical tool for versatile biomedical applications. Especially, the prosperity of nanotechnology and nanomedicine invigorates the landscape of ultrasound-based medicine. The unprecedented surge in research enthusiasm and dedicated efforts have led to a mass of multifunctional micro-/nanosystems being applied in ultrasound biomedicine, facilitating precise diagnosis, effective treatment, and personalized theranostics. The effective deployment of versatile ultrasound-based micro-/nanosystems in biomedical applications is rooted in a profound understanding of the relationship among composition, structure, property, bioactivity, application, and performance. In this comprehensive review, we elaborate on the general principles regarding the design, synthesis, functionalization, and optimization of ultrasound-based micro-/nanosystems for abundant biomedical applications. In particular, recent advancements in ultrasound-based micro-/nanosystems for diagnostic imaging are meticulously summarized. Furthermore, we systematically elucidate state-of-the-art studies concerning recent progress in ultrasound-based micro-/nanosystems for therapeutic applications targeting various pathological abnormalities including cancer, bacterial infection, brain diseases, cardiovascular diseases, and metabolic diseases. Finally, we conclude and provide an outlook on this research field with an in-depth discussion of the challenges faced and future developments for further extensive clinical translation and application.


Assuntos
Neoplasias , Humanos , Animais , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Ultrassonografia/métodos , Nanomedicina/métodos , Nanotecnologia/métodos
7.
Proc Natl Acad Sci U S A ; 120(13): e2218847120, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36940339

RESUMO

Surface tension provides microbubbles (MB) with a perfect spherical shape. Here, we demonstrate that MB can be engineered to be nonspherical, endowing them with unique features for biomedical applications. Anisotropic MB were generated via one-dimensionally stretching spherical poly(butyl cyanoacrylate) MB above their glass transition temperature. Compared to their spherical counterparts, nonspherical polymeric MB displayed superior performance in multiple ways, including i) increased margination behavior in blood vessel-like flow chambers, ii) reduced macrophage uptake in vitro, iii) prolonged circulation time in vivo, and iv) enhanced blood-brain barrier (BBB) permeation in vivo upon combination with transcranial focused ultrasound (FUS). Our studies identify shape as a design parameter in the MB landscape, and they provide a rational and robust framework for further exploring the application of anisotropic MB for ultrasound-enhanced drug delivery and imaging applications.


Assuntos
Barreira Hematoencefálica , Microbolhas , Barreira Hematoencefálica/diagnóstico por imagem , Ultrassonografia , Transporte Biológico , Sistemas de Liberação de Medicamentos
8.
Proc Natl Acad Sci U S A ; 120(18): e2300291120, 2023 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-37098060

RESUMO

Transcranial low-intensity ultrasound is a promising neuromodulation modality, with the advantages of noninvasiveness, deep penetration, and high spatiotemporal accuracy. However, the underlying biological mechanism of ultrasonic neuromodulation remains unclear, hindering the development of efficacious treatments. Here, the well-known Piezo1 was studied through a conditional knockout mouse model as a major mediator for ultrasound neuromodulation ex vivo and in vivo. We showed that Piezo1 knockout (P1KO) in the right motor cortex of mice significantly reduced ultrasound-induced neuronal calcium responses, limb movement, and muscle electromyogram (EMG) responses. We also detected higher Piezo1 expression in the central amygdala (CEA), which was found to be more sensitive to ultrasound stimulation than the cortex was. Knocking out the Piezo1 in CEA neurons showed a significant reduction of response under ultrasound stimulation, while knocking out astrocytic Piezo1 showed no-obvious changes in neuronal responses. Additionally, we excluded an auditory confound by monitoring auditory cortical activation and using smooth waveform ultrasound with randomized parameters to stimulate P1KO ipsilateral and contralateral regions of the same brain and recording evoked movement in the corresponding limb. Thus, we demonstrate that Piezo1 is functionally expressed in different brain regions and that it is an important mediator of ultrasound neuromodulation in the brain, laying the ground for further mechanistic studies of ultrasound.


Assuntos
Córtex Auditivo , Encéfalo , Camundongos , Animais , Encéfalo/fisiologia , Córtex Auditivo/metabolismo , Ultrassonografia , Neurônios/metabolismo , Camundongos Knockout , Canais Iônicos/genética , Canais Iônicos/metabolismo
9.
Proc Natl Acad Sci U S A ; 120(21): e2212933120, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37186852

RESUMO

The glymphatic system is a perivascular fluid transport system for waste clearance. Glymphatic transport is believed to be driven by the perivascular pumping effect created by the pulsation of the arterial wall caused by the cardiac cycle. Ultrasound sonication of circulating microbubbles (MBs) in the cerebral vasculature induces volumetric expansion and contraction of MBs that push and pull on the vessel wall to generate a MB pumping effect. The objective of this study was to evaluate whether glymphatic transport can be mechanically manipulated by focused ultrasound (FUS) sonication of MBs. The glymphatic pathway in intact mouse brains was studied using intranasal administration of fluorescently labeled albumin as fluid tracers, followed by FUS sonication at a deep brain target (thalamus) in the presence of intravenously injected MBs. Intracisternal magna injection, the conventional technique used in studying glymphatic transport, was employed to provide a comparative reference. Three-dimensional confocal microscopy imaging of optically cleared brain tissue revealed that FUS sonication enhanced the transport of fluorescently labeled albumin tracer in the perivascular space (PVS) along microvessels, primarily the arterioles. We also obtained evidence of FUS-enhanced penetration of the albumin tracer from the PVS into the interstitial space. This study revealed that ultrasound combined with circulating MBs could mechanically enhance glymphatic transport in the brain.


Assuntos
Sistema Glinfático , Microbolhas , Camundongos , Animais , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Sistema Glinfático/diagnóstico por imagem , Sistema Glinfático/metabolismo , Ultrassonografia , Albuminas/metabolismo
10.
J Neurosci ; 44(9)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38253533

RESUMO

Increasing evidence has suggested a link between cerebrovascular disease and the cognitive impairment associated with Alzheimer's disease. However, detailed descriptions of microvascular changes across brain regions and how they relate to other more traditional pathology have been lacking. Additionally, the efforts to elucidate the interplay between cerebral microvascular function and Alzheimer's disease progression are complicated by the necessity of probing deep-brain structures since early-stage Alzheimer's disease typically involves hippocampal pathology. The purpose of this study was to examine changes in microvascular dynamics in a mouse model of Alzheimer's disease using cohorts that were age-matched to wild-type controls. Data from both sexes were included in this study. Super-resolution ultrasound localization microscopy revealed microvascular functional and structural features throughout the whole brain depth to visualize and quantify. We found that functional decreases in hippocampal and entorhinal flow velocity preceded structural derangements in regional vascular density. Co-registered histological sectioning confirmed the regionalized perfusion deficits seen on ultrasound imaging, which were co-localized with amyloid beta plaque deposition. In addition to providing global vascular quantifications of deep brain structures with a high local resolution, this technology also permitted velocity-profile analysis of individual vessels and, in some cases, allowed for decoupling of arterial and venous flow contributions. These data suggest that microvascular pathology is an early and pervasive feature of Alzheimer's disease and may represent a novel therapeutic target for this disease.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Masculino , Camundongos , Feminino , Animais , Doença de Alzheimer/complicações , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/patologia , Peptídeos beta-Amiloides/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Modelos Animais de Doenças , Ultrassonografia
11.
N Engl J Med ; 386(10): 923-932, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35263518

RESUMO

BACKGROUND: In patients with low-risk differentiated thyroid cancer undergoing thyroidectomy, the postoperative administration of radioiodine (iodine-131) is controversial in the absence of demonstrated benefits. METHODS: In this prospective, randomized, phase 3 trial, we assigned patients with low-risk differentiated thyroid cancer who were undergoing thyroidectomy to receive ablation with postoperative administration of radioiodine (1.1 GBq) after injections of recombinant human thyrotropin (radioiodine group) or to receive no postoperative radioiodine (no-radioiodine group). The primary objective was to assess whether no radioiodine therapy was noninferior to radioiodine therapy with respect to the absence of a composite end point that included functional, structural, and biologic abnormalities at 3 years. Noninferiority was defined as a between-group difference of less than 5 percentage points in the percentage of patients who did not have events that included the presence of abnormal foci of radioiodine uptake on whole-body scanning that required subsequent treatment (in the radioiodine group only), abnormal findings on neck ultrasonography, or elevated levels of thyroglobulin or thyroglobulin antibodies. Secondary end points included prognostic factors for events and molecular characterization. RESULTS: Among 730 patients who could be evaluated 3 years after randomization, the percentage of patients without an event was 95.6% (95% confidence interval [CI], 93.0 to 97.5) in the no-radioiodine group and 95.9% (95% CI, 93.3 to 97.7) in the radioiodine group, a difference of -0.3 percentage points (two-sided 90% CI, -2.7 to 2.2), a result that met the noninferiority criteria. Events consisted of structural or functional abnormalities in 8 patients and biologic abnormalities in 23 patients with 25 events. Events were more frequent in patients with a postoperative serum thyroglobulin level of more than 1 ng per milliliter during thyroid hormone treatment. Molecular alterations were similar in patients with or without an event. No treatment-related adverse events were reported. CONCLUSIONS: In patients with low-risk thyroid cancer undergoing thyroidectomy, a follow-up strategy that did not involve the use of radioiodine was noninferior to an ablation strategy with radioiodine regarding the occurrence of functional, structural, and biologic events at 3 years. (Funded by the French National Cancer Institute; ESTIMABL2 ClinicalTrials.gov number, NCT01837745.).


Assuntos
Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/radioterapia , Neoplasias da Glândula Tireoide/cirurgia , Tireoidectomia , Adulto , Terapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Prognóstico , Qualidade de Vida , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
12.
Development ; 149(16)2022 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-35912573

RESUMO

Gastrointestinal motor activity has been extensively studied in adults; however, only few studies have investigated fetal motor skills. It is unknown when the gastrointestinal tract starts to contract during the embryonic period and how this function evolves during development. Here, we adapted a non-invasive high-resolution echography technique combined with speckle tracking analysis to examine the gastrointestinal tract motor activity dynamics during chick embryo development. We provided the first recordings of fetal gastrointestinal motility in living embryos without anesthesia. We found that, although gastrointestinal contractions appear very early during development, they become synchronized only at the end of the fetal period. To validate this approach, we used various pharmacological inhibitors and BAPX1 gene overexpression in vivo. We found that the enteric nervous system determines the onset of the synchronized contractions in the stomach. Moreover, alteration of smooth muscle fiber organization led to an impairment of this functional activity. Altogether, our findings show that non-invasive high-resolution echography and speckle tracking analysis allows visualization and quantification of gastrointestinal motility during development and highlight the progressive acquisition of functional and coordinated gastrointestinal motility before birth.


Assuntos
Sistema Nervoso Entérico , Motilidade Gastrointestinal , Animais , Embrião de Galinha , Motilidade Gastrointestinal/fisiologia , Trato Gastrointestinal/diagnóstico por imagem , Miócitos de Músculo Liso , Ultrassonografia
13.
Annu Rev Biomed Eng ; 26(1): 49-65, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38166185

RESUMO

The democratization of ultrasound imaging refers to the process of making ultrasound technology more accessible. Traditionally, ultrasound imaging has been predominately used in specialized medical facilities by trained professionals. Advancements in technology and changes in the health-care landscape have inspired efforts to broaden the availability of ultrasound imaging to various settings such as remote and resource-limited areas. In this review, we highlight several key factors that have contributed to the ongoing democratization of ultrasound imaging, including portable and handheld devices, recent advancements in technology, and training and education. Examples of diagnostic point-of-care ultrasound (POCUS) imaging used in emergency and critical care, gastroenterology, musculoskeletal applications, and other practices are provided for both human and veterinary medicine. Open challenges and the future of POCUS imaging are presented, including the emerging role of artificial intelligence in technology development.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Medicina Veterinária , Humanos , Ultrassonografia/métodos , Ultrassonografia/instrumentação , Medicina Veterinária/métodos , Animais , Inteligência Artificial
14.
CA Cancer J Clin ; 68(2): 97-105, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29369334

RESUMO

Incidental thyroid nodules that are found on an imaging study performed for reasons other than thyroid pathology represent a common scenario encountered by health care providers. The initial workup for these nodules comprises a thorough history and physical examination, thyroid function tests, a dedicated thyroid ultrasound, and fine-needle aspiration of any suspicious lesions. Management ranges from observation and reassurance to surgical resection and depends on the cytologic diagnosis. In cases of cytologically indeterminate or discordant nodules, surgical excision (lobectomy) offers a definitive diagnosis, although molecular testing or a reasonable period of observation may be useful as less invasive adjuncts. CA Cancer J Clin 2018;68:97-105. © 2018 American Cancer Society.


Assuntos
Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/diagnóstico , Biópsia por Agulha Fina , Diagnóstico Diferencial , Humanos , Achados Incidentais , Técnicas de Diagnóstico Molecular , Tomografia por Emissão de Pósitrons/métodos , Guias de Prática Clínica como Assunto , Testes de Função Tireóidea , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/cirurgia , Ultrassonografia/métodos
18.
Proc Natl Acad Sci U S A ; 119(21): e2115821119, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35580186

RESUMO

Neurons of the peripheral nervous system (PNS) are tasked with diverse roles, from encoding touch, pain, and itch to interoceptive control of inflammation and organ physiology. Thus, technologies that allow precise control of peripheral nerve activity have the potential to regulate a wide range of biological processes. Noninvasive modulation of neuronal activity is an important translational application of focused ultrasound (FUS). Recent studies have identified effective strategies to modulate brain circuits; however, reliable parameters to control the activity of the PNS are lacking. To develop robust noninvasive technologies for peripheral nerve modulation, we employed targeted FUS stimulation and electrophysiology in mouse ex vivo skin-saphenous nerve preparations to record the activity of individual mechanosensory neurons. Parameter space exploration showed that stimulating neuronal receptive fields with high-intensity, millisecond FUS pulses reliably and repeatedly evoked one-to-one action potentials in all peripheral neurons recorded. Interestingly, when neurons were classified based on neurophysiological properties, we identified a discrete range of FUS parameters capable of exciting all neuronal classes, including myelinated A fibers and unmyelinated C fibers. Peripheral neurons were excited by FUS stimulation targeted to either cutaneous receptive fields or peripheral nerves, a key finding that increases the therapeutic range of FUS-based peripheral neuromodulation. FUS elicited action potentials with millisecond latencies compared with electrical stimulation, suggesting ion channel­mediated mechanisms. Indeed, FUS thresholds were elevated in neurons lacking the mechanically gated channel PIEZO2. Together, these results demonstrate that transcutaneous FUS drives peripheral nerve activity by engaging intrinsic mechanotransduction mechanisms in neurons [B. U. Hoffman, PhD thesis, (2019)].


Assuntos
Canais Iônicos , Neurônios , Sistema Nervoso Periférico , Estimulação Elétrica Nervosa Transcutânea , Potenciais de Ação , Animais , Interneurônios , Mamíferos , Neurônios/fisiologia , Sistema Nervoso Periférico/fisiologia , Ultrassonografia/métodos
19.
Proc Natl Acad Sci U S A ; 119(46): e2206828119, 2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36343238

RESUMO

Focused ultrasound (FUS) is a powerful tool for noninvasive modulation of deep brain activity with promising therapeutic potential for refractory epilepsy; however, tools for examining FUS effects on specific cell types within the deep brain do not yet exist. Consequently, how cell types within heterogeneous networks can be modulated and whether parameters can be identified to bias these networks in the context of complex behaviors remains unknown. To address this, we developed a fiber Photometry Coupled focused Ultrasound System (PhoCUS) for simultaneously monitoring FUS effects on neural activity of subcortical genetically targeted cell types in freely behaving animals. We identified a parameter set that selectively increases activity of parvalbumin interneurons while suppressing excitatory neurons in the hippocampus. A net inhibitory effect localized to the hippocampus was further confirmed through whole brain metabolic imaging. Finally, these inhibitory selective parameters achieved significant spike suppression in the kainate model of chronic temporal lobe epilepsy, opening the door for future noninvasive therapies.


Assuntos
Epilepsia do Lobo Temporal , Epilepsia , Animais , Epilepsia/terapia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Ultrassonografia , Hipocampo/diagnóstico por imagem
20.
Nano Lett ; 24(1): 209-214, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38156794

RESUMO

Despite the real-time, nonionizing, and cost-effective nature of ultrasound imaging, there is a dearth of methods to visualize two or more populations of contrast agents simultaneously─a technique known as multiplex imaging. Here, we present a new approach to multiplex ultrasound imaging using perfluorocarbon (PFC) nanodroplets. The nanodroplets, which undergo a liquid-to-gas phase transition in response to an acoustic trigger, act as activatable contrast agents. This work characterized the dynamic responses of two PFC nanodroplets with boiling points of 28 and 56 °C. These characteristic responses were then used to demonstrate that the relative concentrations of the two populations of PFC nanodroplets could be accurately measured in the same imaging volume within an average error of 1.1%. Overall, the findings indicate the potential of this approach for multiplex ultrasound imaging, allowing for the simultaneous visualization of multiple molecular targets simultaneously.


Assuntos
Meios de Contraste , Fluorocarbonos , Ultrassonografia/métodos , Transição de Fase , Acústica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa