Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.738
Filtrar
Mais filtros

Eixos temáticos
Intervalo de ano de publicação
1.
BMC Med ; 22(1): 324, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39113028

RESUMO

BACKGROUND: A stent with characteristics of a hybrid design may have advantages in improving the patency of symptomatic iliofemoral vein obstruction. This study assessed the safety and effectiveness of the V-Mixtent Venous Stent in treating symptomatic iliofemoral outflow obstruction. METHODS: Eligible patients had a Clinical-Etiologic-Anatomic-Physiologic (CEAP) C classification of ≥ 3 or a Venous Clinical Severity Score (VCSS) pain score of ≥ 2. The primary safety endpoint was the rate of major adverse events within 30 days. The primary effectiveness endpoint was the 12-month primary patency rate. Secondary endpoints included changes in VCSS from baseline to 6 and 12 months, alterations in CEAP C classification, Chronic Venous Disease Quality of Life Questionnaire (CIVIQ-14) scores at 12 months, and stent durability measures. RESULTS: Between December 2020 and November 2021, 171 patients were enrolled across 15 institutions. A total of 185 endovenous stents were placed, with 91.81% of subjects receiving one stent and 8.19% receiving 2 stents. Within 30 days, only two major adverse events occurred (1.17%; 95% confidence interval [CI], 0.14-4.16%), below the literature-defined performance goal of 11% (P < .001). The 12-month primary patency rate (91.36%; 95% CI, 85.93-95.19%; P < .001) exceeded the literature-defined performance goal. VCSS changes from baseline demonstrated clinical improvement at 6 months (- 4.30 ± 3.66) and 12 months (- 4.98 ± 3.67) (P < .001). Significant reduction in symptoms, as measured by CEAP C classification and CIVIQ-14, was observed from pre-procedure to 12 months (P < .001). CONCLUSIONS: The 12-month outcomes confirm the safety and effectiveness of the V-Mixtent Venous Stent in managing symptomatic iliofemoral venous outflow obstruction, including clinical symptom improvement compared to before treatment.


Assuntos
Veia Femoral , Veia Ilíaca , Stents , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Veia Femoral/cirurgia , Veia Ilíaca/cirurgia , Resultado do Tratamento , Adulto , Idoso , Qualidade de Vida
2.
Small ; 20(34): e2312191, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38488706

RESUMO

Acute thrombosis and its complications are leading global causes of disability and death. Existing thrombolytic drugs, such as alteplase and urokinase (UK), carry a significant bleeding risk during clinical treatments. Thus, the development of a novel thrombolysis strategy is of utmost urgency. Based on the previous work, the hollow structure of microcapsules (MC) is fabricated. Subsequently, armor-piercing MC, known as Fucoidan/S-Nitrosoglutathione/Melanin@MC (FGM@MC) is obtained, using a layer-by-layer (LBL) self-assembly method. Utilizing near-infrared (NIR) light as a trigger, the FGM@MC demonstrated photothermal thrombolysis at the site of thrombus due to its stable and outstanding photothermal properties. Simultaneously, photothermal stimulation leads to the release of a significant amount of nitric oxide from the FGM@MC, resulting in cavitation effects for mechanical thrombolysis. In vivo experiments confirmed the stable release of nitric oxide under NIR light irradiation. Treatment of femoral vein thrombosis in rats revealed that the thrombolytic effectiveness of FGM@MC+NIR (53.71%) is comparable to that of UK (59.70%). Notably, FGM@MC does not interfere with the coagulation function of rats and exhibits a favorable safety profile. In conclusion, this study demonstrates that the drug-free armor-piercing microcapsule has significant potential in the treatment of thrombosis, offering a safe and effective alternative to traditional thrombolytic therapies.


Assuntos
Cápsulas , Raios Infravermelhos , Trombose Venosa , Animais , Trombose Venosa/terapia , Veia Femoral , Ratos , Ratos Sprague-Dawley , Óxido Nítrico/metabolismo , Óxido Nítrico/química , Masculino , Fibrinolíticos/uso terapêutico , Fibrinolíticos/química , Fibrinolíticos/farmacologia
3.
J Cardiovasc Electrophysiol ; 35(8): 1701-1705, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38845191

RESUMO

INTRODUCTION: Transvenous lead extractions (TLEs) for cardiac implantable electronic device complications often encounter difficulties with strong adhesions to the myocardium or vessels. In this report, we introduce a novel "Four-Stage Rocket" technique for effective TLE in cases where conventional methods fail. METHODS AND RESULTS: Two challenging cases where conventional TLE methods failed were treated using a combination of four devices: Needle's Eye Snare, Agilis NxT Steerable Introducer, GlideLight Laser sheath, and GORE® DrySeal Flex Introducer sheath, employed via the inferior vena cava. The "Four-Stage Rocket" technique successfully detached firmly adhered leads near the tricuspid valve annulus, where the traditional superior vena cava approach was inadequate. CONCLUSION: The "Four-Stage Rocket" technique offers a potential alternative in complex TLE cases, aligning the laser direction with the adhesion detachment and reducing the tissue damage risk.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Veia Femoral , Lasers , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Masculino , Idoso , Resultado do Tratamento , Feminino , Pessoa de Meia-Idade , Cateterismo Periférico/instrumentação
4.
J Cardiovasc Electrophysiol ; 35(10): 1952-1959, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39099135

RESUMO

INTRODUCTION: Hemostasis following large-bore femoral vein access remains a challenge. Manual compression has been the standard of care but requires bedside staff, prolonged bed rest, and longer length of stay. The LockeT is an external compression device that attempts to address these issues while achieving venous hemostasis. OBJECTIVES: We evaluate postprocedural hemostasis and vascular closure outcomes after using LockeT following cardiac electrophysiologic procedures. METHODS: We performed a single-center, observational study of patients who underwent vascular closure for electrophysiology procedures using LockeT. Postprocedural outcomes were subsequently analyzed. RESULTS: We studied 102 patients (N) for whom LockeT was used to close 182 separate vascular access sites (n). Common procedures were atrial fibrillation ablation (56.9%, N = 58) and left atrial appendage occlusion (28.4%, N = 29). Most often, 8-Fr [48.3% (n = 126)], 11-Fr [27.2% (n = 71)], and 8.5-Fr [16.9% (n = 44)] sheaths were used, with an average procedure time of 82.1 ± 29.4 min. Hemostasis was achieved in 97.8% (n = 187) of all LockeT cases. Time to ambulation and discharge were 3.93 ± 1.10 h and 8.1 ± 4.4 h, respectively. No major complications were noted. Postprocedurally, 52% (N = 53) of patients were discharged on the same day. There were no differences in hemostasis (p = .859) or ambulation times (p = .202) between procedure types. CONCLUSION: The LockeT can effectively close venous access sites with no major complications.


Assuntos
Desenho de Equipamento , Estudos de Viabilidade , Técnicas Hemostáticas , Punções , Dispositivos de Oclusão Vascular , Humanos , Masculino , Feminino , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Fatores de Tempo , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Veia Femoral/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Pressão , Hemorragia/etiologia , Hemorragia/prevenção & controle , Fatores de Risco
5.
J Cardiovasc Electrophysiol ; 35(8): 1656-1662, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38924288

RESUMO

INTRODUCTION: Access site complications remain common following atrial fibrillation (AF) catheter ablation. Femoral vascular closure devices (VCDs) reduce time to hemostasis compared with manual compression, although large-scale data comparing clinical outcomes between the two approaches are lacking. METHODS: Two cohorts of patients undergoing AF ablation were identified from 36 healthcare organizations using a global federated research network (TriNetX): those receiving a VCD for femoral hemostasis, and those not receiving a VCD. A 1:1 propensity score matching (PSM) model based on baseline characteristics was used to create two comparable cohorts. The primary outcome was a composite of all-cause mortality, vascular complications, bleeding events, and need for blood transfusion. Outcomes were assessed during early (within 7 days of ablation) and extended follow-up (within 8-30 days of ablation). RESULTS: After PSM, 28 872 patients were included (14 436 in each cohort). The primary composite outcome occurred less frequently in the VCD cohort during early (1.97% vs. 2.60%, odds ratio (OR) 0.76, 95% confidence interval (CI) 0.65-0.88; p < .001) and extended follow-up (1.15% vs. 1.43%, OR 0.80, 95% CI 0.65-0.98; p = .032). This was driven by a lower rate of vascular complications during early follow-up in the VCD cohort (0.83% vs. 1.26%, OR 0.66, 95% CI 0.52-0.83; p < .001), and fewer bleeding events during early (0.90% vs. 1.23%, OR 0.73, 95% CI 0.58-0.92; p = .007) and extended follow-up (0.36% vs. 0.59%, OR 0.61, 95% CI 0.43-0.86; p = .005). CONCLUSION: Following AF ablation, femoral venous hemostasis with a VCD was associated with reduced complications compared with hemostasis without a VCD.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veia Femoral , Técnicas Hemostáticas , Punções , Dispositivos de Oclusão Vascular , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Fatores de Tempo , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Fatores de Risco , Estudos Retrospectivos , Cateterismo Periférico/efeitos adversos , Medição de Risco , Hemorragia/etiologia , Hemorragia/prevenção & controle
6.
J Vasc Surg ; 80(3): 847-854.e1, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38723910

RESUMO

OBJECTIVE: Vascular access is difficult in patients without suitable arm veins and prior graft infections. The use of femoral vein translocation (FVT) to the upper extremity or contralateral lower extremity for hemodialysis access may be associated with low infection rates and high patency rates. FVT is used for patients without central venous occlusion who have failed prior access either owing to graft infection or repetitive graft thrombosis. The largest case series consists of 30 cases. The objective of this study is to determine the infection incidence, primary patency, primary-assisted patency, and secondary patency rates among FVTs. METHODS: A retrospective chart review was performed on all patients who underwent FVT by a single vascular practice over a 10-year period (2013-2023). Study variables included length to last follow-up (months), prior access, prior graft infection, comorbid conditions, primary patency, primary-assisted patency, secondary patency, postoperative steal syndrome, postoperative graft infection, postoperative harvest site complication, and postoperative lower extremity compartment syndrome. RESULTS: A total of 131 FVTs were performed from 2013 to 2023; 126 patients (47% male, 53% female; 76% Black, 24% White) with a mean age of 52 ± 14 years and a mean body mass index of 29 ± 8 had at least 1 month of follow-up and were included for analysis. The median follow-up was 46 months (interqurtile range, 19-72 months). The mean number of prior permanent accesses was 2.5 ± 1.4. Forty-eight percent of patients had prior graft infections. The primary, primary-assisted, and secondary patency rates were 66%, 93%, and 98%, respectively, at 6 months; 43%, 85%, and 96% at 12 months; 25%, 70%, and 92% at 24 months; 16%, 61%, and 88% at 36 months; and 14%, 56%, and 82% at 48 months. Postoperative steal syndrome and postoperative access infection requiring excision was observed 16% and 5% of patients, respectively. Harvest site complications requiring an additional procedure occurred in 19% of cases. Three patients developed lower extremity compartment syndrome postoperatively, requiring fasciotomy. Six patients developed chronic lower extremity edema after femoral vein harvest. The mean procedure time and hospital length of stay were 197 ± 40 minutes and 3.5 ± 2.8 days, respectively. CONCLUSIONS: FVT is associated with low infection rates and high long-term patency rates. Significant postoperative complications include steal syndrome and harvest site complications. FVT remains a viable option for patients who have failed prior access owing to graft infection or repetitive graft thrombosis.


Assuntos
Derivação Arteriovenosa Cirúrgica , Implante de Prótese Vascular , Veia Femoral , Diálise Renal , Grau de Desobstrução Vascular , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Veia Femoral/cirurgia , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Adulto , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Fatores de Risco , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/etiologia , Extremidade Superior/irrigação sanguínea , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/epidemiologia
7.
J Vasc Interv Radiol ; 35(6): 834-845, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484910

RESUMO

PURPOSE: To report 3-year outcomes from a prospective, multicenter, nonrandomized, single-arm study designed to assess the safety and effectiveness of the Zilver Vena Venous Stent for the treatment of symptomatic iliofemoral venous outflow obstruction. MATERIALS AND METHODS: The VIVO study included patients with symptomatic obstruction of 1 iliofemoral venous segment (ie, 1 limb), characterized by a Clinical, Etiological, Anatomic, Pathophysiology (CEAP) clinical classification of ≥3 or a Venous Clinical Severity Score (VCSS) for pain of ≥2. Patients were retrospectively grouped based on baseline clinical presentation as postthrombotic syndrome (PTS), nonthrombotic iliac vein (NIVL) obstruction, or acute deep vein thrombosis (aDVT). Clinical improvement was assessed by change in VCSS, Venous Disability Score, Chronic Venous Disease Quality of Life Questionnaire (CIVIQ-20) scores, and CEAP C classification. Stent performance was evaluated by rates of patency by ultrasound (US), freedom from clinically driven reintervention, and freedom from stent fracture. RESULTS: The 3-year results for the 243 patients in the VIVO cohort included a 90.3% rate of patency by US and a 92.6% rate of freedom from clinically driven reintervention. The 3-year rates of patency by US for the NIVL, aDVT, and PTS groups were 100%, 84.0%, and 86.1%, respectively. Sustained clinical improvement through 3 years was demonstrated by changes in VCSS, Venous Disability Score, CIVIQ-20, and CEAP C classification. No stent fractures were observed. CONCLUSIONS: The VIVO study demonstrated sustained high rates of patency and freedom from clinically driven reintervention and improvements in venous clinical symptoms through 3 years. Each patient group (NIVL, aDVT, and PTS) showed clinical improvement and sustained patency through 3 years; some variation existed among groups (eg, only the NIVL group had a 100% patency rate).


Assuntos
Procedimentos Endovasculares , Veia Femoral , Veia Ilíaca , Síndrome Pós-Trombótica , Desenho de Prótese , Stents , Grau de Desobstrução Vascular , Humanos , Feminino , Masculino , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/fisiopatologia , Pessoa de Meia-Idade , Veia Femoral/diagnóstico por imagem , Veia Femoral/fisiopatologia , Resultado do Tratamento , Estudos Prospectivos , Fatores de Tempo , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Síndrome Pós-Trombótica/fisiopatologia , Síndrome Pós-Trombótica/terapia , Síndrome Pós-Trombótica/diagnóstico por imagem , Síndrome Pós-Trombótica/etiologia , Idoso , Adulto , Trombose Venosa/terapia , Trombose Venosa/fisiopatologia , Trombose Venosa/diagnóstico por imagem , Estados Unidos , Qualidade de Vida , Avaliação da Deficiência
8.
J Vasc Interv Radiol ; 35(5): 664-675.e5, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38336032

RESUMO

PURPOSE: To report 36-month outcomes and subgroup analysis of the ABRE study evaluating the safety and effectiveness of the Abre venous self-expanding stent system for the treatment of symptomatic iliofemoral venous outflow obstruction disease. METHODS: The ABRE study was a prospective, multicenter, nonrandomized study that enrolled and implanted Abre venous stents in 200 participants (mean age 51.5 years [SD ± 15.9], 66.5% women) with symptomatic iliofemoral venous outflow obstruction at 24 global sites. Outcomes assessed through 36 months included patency, major adverse events, stent migration, stent fracture, and quality-of-life changes. Adverse events and imaging studies were adjudicated by independent clinical events committee and core laboratories, respectively. RESULTS: Primary, primary-assisted, and secondary patency through 36 months by Kaplan-Meier estimates were 81.6%, 84.8%, and 86.3%, respectively. The cumulative incidence of major adverse events through 36 months was 10.2%, mainly driven by 12 thrombosis events. Subgroup analyses demonstrated a primary patency of 76.5% in the acute deep vein thrombosis group, 70.4% in the postthrombotic syndrome group, and 97.1% in the nonthrombotic iliac vein lesion group through 36 months. The overall mean lesion length was 112.4 mm (SD ± 66.1). There were no stent fractures or migrations in this study. Quality of life and venous functional assessments demonstrated significant improvements from baseline to 36 months across all patient subsets. CONCLUSIONS: Results from the ABRE study demonstrated sustained patency with a good safety profile after implantation of a dedicated venous stent in patients with symptomatic iliofemoral venous outflow obstruction disease.


Assuntos
Procedimentos Endovasculares , Veia Femoral , Veia Ilíaca , Desenho de Prótese , Qualidade de Vida , Stents , Grau de Desobstrução Vascular , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Veia Femoral/diagnóstico por imagem , Veia Femoral/fisiopatologia , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/fisiopatologia , Síndrome de May-Thurner/diagnóstico por imagem , Síndrome de May-Thurner/terapia , Síndrome de May-Thurner/fisiopatologia , Síndrome Pós-Trombótica/diagnóstico por imagem , Síndrome Pós-Trombótica/fisiopatologia , Síndrome Pós-Trombótica/etiologia , Síndrome Pós-Trombótica/terapia , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/fisiopatologia , Trombose Venosa/terapia
9.
Eur J Vasc Endovasc Surg ; 68(4): 521-528, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38906369

RESUMO

OBJECTIVE: Iliofemoral venous obstructive disease can result in significant, potentially debilitating symptoms that can negatively affect quality of life. Unlike arterial disease, patients with deep venous disease have a significantly lower median age, therefore the need for long term stent patency becomes a matter of decades rather than years. Furthermore, iliofemoral lesions frequently require stent placement across the inguinal ligament. Such stents are subject to dynamic stress from leg movement and associated concerns for device fatigue, resulting in stent fracture. The aim of this study was to describe an in vitro 50 year stent fatigue test method designed to assess durability against dynamic stress induced device fracture. METHODS: Through literature review, cadaver studies, and computer modelling, the most challenging loading was confirmed to be hip flexion across the inguinal ligament. This occurs when the patient adjusts between a seated and standing position. Sit to stand hip flexion at the inguinal ligament was effectively simulated on the bench in this in vitro experimental study. RESULTS: When tested under challenge parameters, hip flexion was reliably found to cause fractures in non-venous nitinol stents. However, a dedicated self expanding nitinol venous stent, engineered for improved durability, underwent up to 50 years of simulated loading on the bench with 15% (3/20) of stents experiencing fractures at 50 years, compared with fractures in 35% (14/40) of non-venous stents tested to 1.4 years; no statistical testing was performed as durations do not match and the objective was to demonstrate the test method. CONCLUSION: The presented fatigue test method is a suitable approach for evaluating the durability of stents intended for venous use. Venous stents demonstrated superior fatigue resistance compared with non-venous stents via in vitro hip flexion testing.


Assuntos
Ligas , Teste de Materiais , Falha de Prótese , Stents , Humanos , Stents/efeitos adversos , Desenho de Prótese , Estresse Mecânico , Fatores de Tempo , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Veia Ilíaca/fisiopatologia , Veia Ilíaca/cirurgia , Veia Femoral , Análise de Falha de Equipamento
10.
Eur J Vasc Endovasc Surg ; 67(4): 644-652, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37981003

RESUMO

OBJECTIVE: To compare thrombus removal and residual venous symptoms and signs of disease following interventional treatment of iliofemoral deep vein thrombosis (DVT) with mechanical thrombectomy (MT) and pharmacomechanical catheter directed thrombolysis (PCDT). METHODS: Retrospective cohort analysis of propensity score matched subgroups from the multicentre prospective MT ClotTriever Outcomes registry and the PCDT arm of the randomised Acute Venous Thrombosis: Thrombus Removal with Adjunctive Catheter Directed Thrombolysis trial. Patients with bilateral DVT, symptom duration greater than four weeks, isolated femoral-popliteal disease, or incomplete case data were excluded. Patients with iliofemoral DVT were propensity score matched (1:1) on 10 baseline covariables, including race, sex, age, body mass index, leg treated, prior thromboembolism, Marder score, symptom duration, provoked deep vein thrombosis status, and Villalta score. Reduction in post-procedure thrombus burden (i.e., Marder scores), assessment of venous symptoms and signs (i.e., Villalta scores) at 12 months, and healthcare resource utilisation were compared between subgroups. RESULTS: Propensity score matching resulted in 130 patient pairs with no significant differences in baseline characteristics between the MT and PCDT groups. MT was associated with a greater reduction in Marder scores (91.0% vs. 67.7%, p < .001), and a greater proportion of patients at 12 months with no post-thrombotic syndrome (83.1% vs. 63.6%, p = .007) compared with matched patients receiving PCDT. No differences in rates of adjunctive stenting or venoplasty were identified (p = .27). Higher rates of single session treatment were seen with MT (97.7% vs. 26.9%, p < .001), which also showed shorter mean post-procedure hospital stays (1.81 vs. 3.46 overnights, p < .001), and less post-procedure intensive care unit utilisation (2.3% vs. 52.8%, p < .001). CONCLUSION: Compared with PCDT, MT was associated with greater peri-procedural thrombus reduction, more efficient post-procedure care, and improved symptoms and signs of iliofemoral vein disease at 12 months.


Assuntos
Síndrome Pós-Trombótica , Trombose Venosa , Humanos , Terapia Trombolítica/efeitos adversos , Fibrinolíticos , Estudos Retrospectivos , Pontuação de Propensão , Estudos Prospectivos , Veia Femoral/diagnóstico por imagem , Resultado do Tratamento , Veia Ilíaca/diagnóstico por imagem , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/terapia , Síndrome Pós-Trombótica/etiologia , Catéteres , Trombectomia/efeitos adversos
11.
Clin Exp Rheumatol ; 42(10): 2032-2039, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38573067

RESUMO

OBJECTIVES: To evaluate common femoral vein thickness (CFVT) as a diagnostic tool in Brazilian patients with Behçet's disease (BD) and to analyse associations between increased CFVT and disease features. METHODS: A cross-sectional study was performed including 100 BD patients and 100 controls. The CFVT and the diameters of great saphenous vein (GSV), and small saphenous vein (SSV) were measured by Doppler ultrasound. RESULTS: BD patients had higher right CFVT [0.600mm (0.500-0.700) vs. 0.525mm (0.450-0.637); p=0.012] and left CFVT [0.550mm (0.450-0.650) vs. 0.500mm (0.450-0.550); p=0.004] compared to controls. Vascular involvement of BD and previous deep venous thrombosis were associated with increased CFVT (p<0.05). The number of vascular events correlated with right and left CFVT (Rho = 0.475 p=0.030 and Rho = 0.429 p=0.052, respectively). The 0.575mm cut-off point of right and left CFVT had area under the curve (AUC) of 0.602; 95% confidence interval (95% CI): 0.524-0.680 and AUC: 0.615; 95% CI: 0.537-0.693, respectively. The right and left CFVT had a sensitivity for BD diagnosis of 52% and 43%, and a specificity of 64% and 77%, respectively. No significant differences were found between BD patients and controls regarding the GSV and SSV diameters in both legs (p>0.05). CONCLUSIONS: In this study, CFVT measurement was not shown to be a reliable diagnostic test for BD. CFVT was increased in BD patients presenting vascular involvement and correlated with the number of previous events.


Assuntos
Síndrome de Behçet , Veia Femoral , Valor Preditivo dos Testes , Veia Safena , Humanos , Síndrome de Behçet/diagnóstico por imagem , Síndrome de Behçet/complicações , Síndrome de Behçet/diagnóstico , Masculino , Feminino , Estudos Transversais , Adulto , Veia Femoral/diagnóstico por imagem , Pessoa de Meia-Idade , Estudos de Casos e Controles , Veia Safena/diagnóstico por imagem , Brasil/epidemiologia , Ultrassonografia Doppler , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Curva ROC , Área Sob a Curva , Adulto Jovem
12.
Europace ; 26(8)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39051875

RESUMO

AIMS: Leadless pacemaker therapy was introduced to overcome lead- and pocket-related complications in conventional transvenous pacemaker systems. Implantation via the femoral vein, however, may not always be feasible. The aim of this study was to evaluate leadless pacemaker implantation using a jugular vein approach and compare it to the standard implantation via the femoral vein. METHODS AND RESULTS: The records of the first consecutive 100 patients undergoing Micra™ leadless pacemaker implantation via the right internal jugular vein from two centres were included in this study. Peri-procedural safety and efficacy of the jugular approach were compared to the first 100 patients using a femoral implantation approach at the University Hospital Zurich. One hundred patients underwent successful implantation of a leadless pacemaker via the internal jugular vein (mean age, 81.18 ± 8.29, 60% males). Mean procedure time was 35.63 ± 10.29 min with a mean fluoroscopy time of 4.66 ± 5.16 min. The device was positioned at the inferior septum in 25 patients, at the high septum in 24 patients, and mid-septum in 51 patients. The mean pacing threshold was 0.56 ± 0.35 V at 0.24 ms pulse width with a sensed amplitude of 10.0 ± 4.4 mV. At follow-up, electrical parameters remained stable in all patients. Compared with femoral implantation, patients undergoing the jugular approach were of similar age and had similar comorbidities. Mean procedure (48.9 ± 21.0 min) and fluoroscopy times (7.7 ± 7.8 min, both P < 0.01) were shorter compared to the femoral approach. Electrical parameters were similar between the two approaches. There were only two complications during jugular veinous implantations (1 pericardial effusion and 1 dislocation), compared to 16 complications using the femoral approach (1 pericardial effusion, 2 femoral artery injuries, and 13 major groin haematomas). CONCLUSION: The jugular approach may represent a safe and efficient alternative to femoral implantation of the Micra leadless pacemaker.


Assuntos
Estimulação Cardíaca Artificial , Veia Femoral , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estimulação Cardíaca Artificial/métodos , Resultado do Tratamento , Implantação de Prótese/métodos , Desenho de Equipamento , Estudos Retrospectivos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/fisiopatologia , Fatores de Tempo
13.
Semin Dial ; 37(5): 399-403, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38773851

RESUMO

INTRODUCTION: Femoral vein transposition is one of the final resorts for vascular access in patients with exhaustion of upper limb venous patrimony and central venous occlusive disease. Its major pitfalls include hemodialysis access-induced distal ischemia and infection. Surgical procedures may be warranted to preserve vascular access if ischemia develops. Several techniques are reported in the literature for femoral vein transposition. CASE REPORT: We expose an endoscopic femoral vein harvesting as an alternative to the single thigh incision in order to avoid its associated complications. In the setting of ischemia, proximalization of arterial inflow was used to manage femoral vein transposition associated limb ischemia. CONCLUSION: This case report aims to expose the aforementioned unreported surgical techniques for lower limb arteriovenous fistula, its advantages, and pitfalls, as well as considerations on its future use.


Assuntos
Derivação Arteriovenosa Cirúrgica , Artéria Femoral , Veia Femoral , Isquemia , Diálise Renal , Humanos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Derivação Arteriovenosa Cirúrgica/métodos , Isquemia/etiologia , Isquemia/cirurgia , Diálise Renal/métodos , Artéria Femoral/cirurgia , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Feminino
14.
Pacing Clin Electrophysiol ; 47(8): 988-993, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38967390

RESUMO

INTRODUCTION: Successful implantations of the Aveir VR, have been effectively demonstrated in adults; however, there remain limited reports supporting safe and feasible implantation of the Aveir VR in the young population. METHODS: Retrospective, observational study of Aveir VR implantation of young patients (≦21 years old) at UC Davis Medical Center from November 2022 to January 2024 via the internal jugular or femoral vein implantation approaches. Indications for pacing, patient demographics, pacing thresholds and longevity were reported at the time of implantation and last follow-up. RESULTS: A total of 10 patients received the Aveir VR with a median age of years (IQR 12.5-17) and median weight of 50.8 kg (IQR 44.6-60.9) kg. The majority were male (80%). Aveir VR leadless pacemaker occurred via internal jugular venous (90%) or femoral venous (10%) approaches. Indications for placement were intermittent complete heart block (60%) and sinus pauses (40%). Adequate impedance, sensing and thresholds were maintained from implantation to a median follow-up of 9 months. Predicted pacemaker longevity at follow-up median was 23.8 years. There were no complications in any of the 10 patients. CONCLUSION: Aveir VR implantation via the internal jugular and femoral veins is feasible in the young patient population with stable pacing parameters at follow-up.


Assuntos
Veia Femoral , Marca-Passo Artificial , Humanos , Masculino , Feminino , Estudos Retrospectivos , Adolescente , Criança , Veias Jugulares , Remoção de Dispositivo , Estimulação Cardíaca Artificial/métodos
15.
Pacing Clin Electrophysiol ; 47(2): 330-335, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38240379

RESUMO

OBJECTIVE: This study aims to investigate the anatomical variations in femoral vasculature and evaluate the clinical value of ultrasound-guided femoral vein puncture in catheter ablation procedures. METHODS: In this retrospective analysis conducted from January 2023 to March 2023, we examined data from patients who underwent catheter ablation with ultrasound-guided femoral venipuncture. We evaluated the anatomy of the femoral vasculature at both high and low inguinal levels. Based on the relationship between the femoral vein and artery, we classified the anatomy into four types: Type I (vein parallel to artery without overlap), Type II (vein medial to artery with lumen overlap ≤50%), Type III (vein posterior to artery with lumen overlap > 50%), and Type IV (vein lateral to artery). Additionally, we assessed procedure-related vascular complications that required interventions or prolonged hospital stays. RESULTS: A total of 254 patients were included in this study. At the upper inguinal level, most cases (92.5%) exhibited Type II, followed by Type I (6.5%), while Type III (0.6%) and IV (0.4%) were less common. At the lower inguinal level, Type II accounted for 70.7%, there was a significantly higher proportion of Type III (23.4%) and Type IV (5.9%). The overall complication rate was 0.4%, no pseudoaneurysm or hematoma was observed in our study. CONCLUSION: Our study revealed significant anatomical variations in the relationship between the femoral vein and femoral artery. Ultrasound-guided femoral venipuncture significantly reduced vascular complication rate, making it a valuable tool for guiding puncture procedures.


Assuntos
Ablação por Cateter , Flebotomia , Humanos , Veia Femoral/diagnóstico por imagem , Veia Femoral/cirurgia , Estudos Retrospectivos , Arritmias Cardíacas , Punções/métodos , Artéria Femoral/cirurgia , Artéria Femoral/diagnóstico por imagem , Ultrassonografia de Intervenção
16.
Ann Vasc Surg ; 100: 184-189, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37865169

RESUMO

BACKGROUND: The aim of this study was to assess the role of treatment of superficial venous reflux (SVR) in patients with combined deep segmental venous reflux as regards clinical symptoms as well as reflux improvement of the deep veins. METHODS: We reviewed 80 patients, retrospectively selected on the inclusion criteria and having combined SVR and segmental deep venous reflux who underwent SVR ablation. The contralateral limb of 44 patients was used as a control group, asked to wear compression stockings for 3 months during day time with no surgical intervention. Duplex ultrasounds follow-up was performed at 3, 6, and 12 months postoperatively. Clinical severity of venous disease was graded from C1 to C6 according to the CEAP (Clinical, Etiology, Anatomy, and Pathophysiology) classification. Duplex ultrasound was done in both supine and standing positions with non-weight-bearing of the examined limb. The venous reflux time, the venous flow volume and the peak venous flow velocity were registered. Removal of SVR was performed using either conventional surgery or radiofrequency ablation. The patient was required to wear compression stockings during the day time for the following weeks. RESULTS: During the follow-up period, all patients were improved clinically as regards pain, edema, and ulcer healing. All patients included in this study had no signs of residual SVR. Corrected deep venous segment reflux was in 36 (45%). Similar data at 3, 6, and 12 months postoperatively after SVR removal. The popliteal vein reflux responded less than the femoral vein reflux did. CONCLUSIONS: Treatment of the SVR eliminates segmental deep venous reflux in a good percentage of patients regardless of the treatment modality. Also, symptoms improvement and ulcer healing were documented, and hence, more studies are recommended to evaluate this role.


Assuntos
Doenças Vasculares , Insuficiência Venosa , Humanos , Úlcera , Estudos Retrospectivos , Resultado do Tratamento , Veia Femoral/diagnóstico por imagem , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/cirurgia , Doença Crônica
17.
Ann Vasc Surg ; 106: 152-161, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38815910

RESUMO

BACKGROUND: The anticoagulation strategy of switching to rivaroxaban after 1 week of initial low-molecular-weight heparin (LMWH) therapy is recommended by a guideline for the treatment of acute iliofemoral deep vein thrombosis (DVT). However, the initial rivaroxaban dose in the switching strategy, as well as the effectiveness and safety of the early switching (less than 1 week) to rivaroxaban, remain inadequately substantiated. We aimed to evaluate the effectiveness and safety of early switching from LMWH to maintenance therapy of rivaroxaban (20 mg once daily) for acute iliofemoral DVT. METHODS: A retrospective cohort study was conducted using data from patients with acute iliofemoral DVT who received initial LMWH anticoagulation followed by rivaroxaban maintenance therapy. The clinical outcomes were compared between early (LMWH course ≤7 days) and routine (LMWH course >7 days) switching strategies within 3 months of initiating anticoagulation. RESULTS: 217 patients were included, 59 (27.2%) receiving early switching and 158 (72.8%) receiving routine switching. Compared with routine switching, patients with early switching had a significantly shorter hospital stay (7 days vs. 14 days, P < 0.001). The length of hospital stay was significantly positively correlated with the duration of LMWH (r = 0.762, P < 0.001). The incidences of recurrent venous thromboembolism (5.1% vs. 2.5%, P = 0.606), major bleeding (0% vs. 1.9%, P = 0.564), clinically relevant nonmajor bleeding (1.7% vs. 2.5%, P = 1.000) and all-cause mortality (6.8% vs. 2.5%, P = 0.283) were not statistically different between the 2 groups. CONCLUSIONS: Direct early switching from LMWH to maintenance therapy of rivaroxaban is effective and safe for acute iliofemoral DVT.


Assuntos
Esquema de Medicação , Substituição de Medicamentos , Inibidores do Fator Xa , Veia Femoral , Hemorragia , Heparina de Baixo Peso Molecular , Veia Ilíaca , Rivaroxabana , Trombose Venosa , Humanos , Rivaroxabana/efeitos adversos , Rivaroxabana/administração & dosagem , Estudos Retrospectivos , Trombose Venosa/tratamento farmacológico , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/mortalidade , Trombose Venosa/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Resultado do Tratamento , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/administração & dosagem , Fatores de Tempo , Idoso , Hemorragia/induzido quimicamente , Veia Ilíaca/diagnóstico por imagem , Heparina de Baixo Peso Molecular/efeitos adversos , Heparina de Baixo Peso Molecular/administração & dosagem , Fatores de Risco , Adulto , Doença Aguda , Tempo de Internação , Recidiva , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem
18.
BMC Med Imaging ; 24(1): 163, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38956583

RESUMO

PURPOSE: To examine whether there is a significant difference in image quality between the deep learning reconstruction (DLR [AiCE, Advanced Intelligent Clear-IQ Engine]) and hybrid iterative reconstruction (HIR [AIDR 3D, adaptive iterative dose reduction three dimensional]) algorithms on the conventional enhanced and CE-boost (contrast-enhancement-boost) images of indirect computed tomography venography (CTV) of lower extremities. MATERIALS AND METHODS: In this retrospective study, seventy patients who underwent CTV from June 2021 to October 2022 to assess deep vein thrombosis and varicose veins were included. Unenhanced and enhanced images were reconstructed for AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images were obtained using subtraction software. Objective and subjective image qualities were assessed, and radiation doses were recorded. RESULTS: The CT values of the inferior vena cava (IVC), femoral vein ( FV), and popliteal vein (PV) in the CE-boost images were approximately 1.3 (1.31-1.36) times higher than in those of the enhanced images. There were no significant differences in mean CT values of IVC, FV, and PV between AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images. Noise in AiCE, AiCE-boost images was significantly lower than in AIDR 3D and AIDR 3D-boost images ( P < 0.05). The SNR (signal-to-noise ratio), CNR (contrast-to-noise ratio), and subjective scores of AiCE-boost images were the highest among 4 groups, surpassing AiCE, AIDR 3D, and AIDR 3D-boost images (all P < 0.05). CONCLUSION: In indirect CTV of the lower extremities images, DLR with the CE-boost technique could decrease the image noise and improve the CT values, SNR, CNR, and subjective image scores. AiCE-boost images received the highest subjective image quality score and were more readily accepted by radiologists.


Assuntos
Meios de Contraste , Aprendizado Profundo , Extremidade Inferior , Flebografia , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Idoso , Flebografia/métodos , Adulto , Algoritmos , Trombose Venosa/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Veia Poplítea/diagnóstico por imagem , Varizes/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Veia Femoral/diagnóstico por imagem , Doses de Radiação , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Intensificação de Imagem Radiográfica/métodos
19.
Am J Emerg Med ; 78: 206-214, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38330835

RESUMO

BACKGROUND: Ultrasound-guided central venous catheterization (CVC) has become the standard of care. However, providers use a variety of approaches, encompassing the internal jugular vein (IJV), supraclavicular subclavian vein (SupraSCV), infraclavicular subclavian vein (InfraSCV), proximal axillary vein (ProxiAV), distal axillary vein (DistalAV), and femoral vein. OBJECTIVE: This review aimed to compare the first-pass success rate and arterial puncture rate for different approaches to ultrasound-guided CVC above the diaphragm. METHODS: In May 2023, Embase, MEDLINE, CENTRAL, ClinicalTrials.gov, and World Health Organization International Clinical Trials Platform were searched for randomized controlled trials (RCTs) comparing the 5 CVC approaches. The Confidence in Network Meta-Analysis tool was used to assess confidence. Thirteen RCTs (4418 participants and 13 comparisons) were included in this review. RESULTS: The SupraSCV approach likely increased the proportion of first-attempt successes compared to the other 4 approaches. The SupraSCV first-attempt success demonstrated risk ratios (RRs) > 1.21 with a lower 95% confidence interval (CI) exceeding 1. Compared to the IJV, the SupraSCV approach likely increased the first-attempt success proportion (RR 1.22; 95% confidence interval [CI] 1.06-1.40, moderate confidence), whereas the DistalAV approach reduced it (RR 0.72; 95% CI 0.59-0.87, high confidence). Artery puncture had little to no difference across all approaches (low to high confidence). CONCLUSION: Considering first-attempt success and mechanical complications, the SupraSCV may emerge as the preferred approach, while DistalAV might be the least preferable approach. Nevertheless, head-to-head studies comparing the approaches with the greatest first attempt success should be undertaken.


Assuntos
Cateterismo Venoso Central , Veias Jugulares , Metanálise em Rede , Veia Subclávia , Ultrassonografia de Intervenção , Humanos , Cateterismo Venoso Central/métodos , Ultrassonografia de Intervenção/métodos , Veia Subclávia/diagnóstico por imagem , Veias Jugulares/diagnóstico por imagem , Pescoço/irrigação sanguínea , Pescoço/diagnóstico por imagem , Veia Femoral/diagnóstico por imagem , Veia Axilar/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
J Cardiothorac Vasc Anesth ; 38(6): 1361-1368, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38555215

RESUMO

OBJECTIVES: The aim of this study was to evaluate if the presence of a pulsatile femoral vein pattern is an indicator of venous congestion in the intensive care unit (ICU). DESIGN: Retrospective observational study. SETTING: Three medico-surgical university-affiliated ICUs. PARTICIPANTS: Adult patients who had an ultrasound evaluation at several time points during their ICU stay: at baseline (within 24 hours of admission to ICU), daily during their ICU stay, and within 24 hours before ICU discharge. INTERVENTIONS: At each time point, the hemodynamic, respiratory, and cardiac ultrasound parameters were recorded. The common femoral vein was studied with pulsed-wave Doppler at the level of the femoral trigonum, with high frequency (5-13 MHz) linear array vascular probe and venous vascular mode, in supine patients. MEASUREMENTS AND MAIN RESULTS: One hundred eight patients who underwent 400 ultrasound evaluations (3.7 ± 1 ultrasound evaluations per patient) during their ICU stay were included. Seventy-nine of 108 patients (73%) had a pulsatile femoral vein pattern at least at 1 time point. The multivariable mixed effects logistic regression model demonstrated an association among pulsatile femoral vein pattern, body mass index (OR: 0.91[95% CI 0.85-0.96], p = 0.002), inferior vena cava mean diameter (OR: 2.35 [95% CI 1.18-4.66], p = 0.014), portal vein pulsatility (OR: 2.3 [95% CI 1.2-4.4], p = 0.012), and congestive renal vein flow pattern (OR: 4.02 [95% CI 2.01-8.03], p < 0.001). The results were confirmed by principal component analysis. CONCLUSION: In the ICU, a pulsatile femoral vein pattern is associated with parameters of venous congestion, independently of the patient's volume status, and ventilatory treatment. These results suggest the femoral vein Doppler pulsatility as a parameter of congestion in ICU patients.


Assuntos
Veia Femoral , Unidades de Terapia Intensiva , Fluxo Pulsátil , Humanos , Feminino , Masculino , Estudos Retrospectivos , Veia Femoral/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Fluxo Pulsátil/fisiologia , Hiperemia/diagnóstico por imagem , Hiperemia/fisiopatologia , Adulto , Cuidados Críticos/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa