Comparación de la eficacia y seguridad de flecainida y dronedarona como terapias antiarrítmicas para mantenimiento de ritmo sinusal en fibrilación auricular / Comparison of the efficacy and safety of dronedarone and flecainide as maintenance antiarrhythmic therapy for sinus rhythm in atrial fibrillation
Sánchez Sorian, Ruth María; Chamorro Fernández, Carlos Israel; Ruiz Nodar, Juan Miguel; Chamorro Fernández, Antonio Javier; Grau Jornet, Guillermo; Nuñez Villota, Julio.
  • Sánchez Sorian, Ruth María; Hospital Virgen de los Lirios. Unidad de Cardiología. Alcoy. ES
  • Chamorro Fernández, Carlos Israel; Hospital Virgen de los Lirios. Unidad de Cardiología. Alcoy. ES
  • Ruiz Nodar, Juan Miguel; Hospital General de Alicante. Servicio de Cardiología. ES
  • Chamorro Fernández, Antonio Javier; Hospital General Universitario de Salamanca. Servicio de Medicina Interna. Salamanca. ES
  • Grau Jornet, Guillermo; Hospital Virgen de los Lirios. Unidad de Cardiología. Alcoy. ES
  • Nuñez Villota, Julio; Hospital Clínico de Valencia. Servicio de Cardiología. Valencia. ES
Arch. cardiol. Méx ; 88(3): 204-211, jul.-sep. 2018. tab, graf
Article en Es | LILACS | ID: biblio-1088751
Biblioteca responsable: BR1.1
RESUMEN
Resumen Introducción y

objetivos:

Dronedarona y flecainida son antiarrítmicos de primera elección para reducir recurrencias de fibrilación auricular (FA), sin existir estudios que los comparen entre sí. Nuestro objetivo es comparar la eficacia en cuanto a prevención de recurrencias y seguridad de ambos fármacos.

Métodos:

Estudio retrospectivo en el que se incluyeron 123 pacientes de forma consecutiva en tratamiento con flecainida o dronedarona desde octubre de 2010 hasta febrero de 2013 por FA paroxística (76.4%) y FA persistente (23.6%). Se realizó cardioversión eléctrica en un 7.3% de los pacientes y farmacológica en un 16.3%. La mediana (rango intercuartílico) de seguimiento fue de 301 días (92-474), con una media de 2.8 revisiones por paciente. Se realizó análisis de tiempo hasta el primer evento mediante Kaplan-Meier y regresión de Cox ajustada por un índice de propensión.

Resultados:

De entre los 123 sujetos incluidos con FA, 71 fueron tratados con flecainida y 52 con dronedarona. Durante el seguimiento se registraron 36 recurrencias y 20 efectos adversos. Se documentaron un 36.6% de recurrencias en los pacientes tratados con flecainida en comparación con un 21% en los tratados con dronedarona (p = 0.073). En el análisis multivariante, dronedarona se mostró al menos tan eficaz como flecainida para prevenir recurrencias de FA (HR 0.53, IC 95% 0.20-1.44, p = 0.221) y demostró un perfil de seguridad comparable al de flecainida (HR 0.68, IC 95% 0.18-2.53, p = 0.566).

Conclusiones:

Según nuestra experiencia, dronedarona resulta al menos tan eficaz como flecainida para el mantenimiento de ritmo sinusal, con un buen perfil de tolerabilidad, a pesar de pautarse en pacientes con un perfil clínico más desfavorable.
ABSTRACT
Abstract Introduction and

objectives:

Dronedarone and flecainide are the first pharmacological choice to reduce recurrence of atrial fibrillation (AF); however, there are no studies comparing them. A study was performed to compare the efficacy in terms of recurrence of AF and safety of both drugs.

Methods:

A retrospective cohort study was conducted that included 123 consecutive patients treated with flecainide or dronedarone due to paroxysmal AF (76.4%) or persistent AF (23.6%), from October 2010 to February 2013. Electrical cardioversion was performed in 7.3% of patients and pharmacological cardioversion in 16.3%. The median (interquartile range) follow-up was 301 days (92-474) with a mean of 2.8 reviews per patient. Time to first event analysis was performed using Kaplan-Meier and Cox regression, adjusted for propensity score.

Results:

Of the 123 consecutive patients with AF included, 71 were on dronedarone and 52 on flecainide. During the follow-up, there were 36 AF recurrences and 20 safety events. There were recurrences in 36.6% of patients treated with flecainide, compared with 21% of those receiving dronedarone (P = .073). Dronedarone showed to be at least as effective as flecainide in preven- ting recurrence of atrial fibrillation (HR 0.53, 95% CI 0.20-1.44, P = .221), and demonstrated an acceptable safety profile when compared with flecainide (HR 0.68, 95% CI 0.18-2.53, P = .566).

Conclusions:

In our experience, dronedarone has been at least as effective and safe as flecainide, despite it was most frequently prescribed in patients with worse baseline risk profile.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: LILACS Asunto principal: Fibrilación Atrial / Flecainida / Dronedarona / Antiarrítmicos Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: Es Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: LILACS Asunto principal: Fibrilación Atrial / Flecainida / Dronedarona / Antiarrítmicos Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: Es Año: 2018 Tipo del documento: Article