Enantioselective analysis of methadone in saliva by liquid chromatography-mass spectrometry.
J Chromatogr A
; 871(1-2): 163-72, 2000 Feb 25.
Article
en En
| MEDLINE
| ID: mdl-10735296
Saliva was tested and evaluated as a biological matrix for methadone (Mtd) monitoring. Conventional method using a narrow bore C18 column, and an enantioselective method using a narrow bore alpha1-acid glycoprotein column, were developed using liquid chromatography coupled with a mass spectromeric (MS) detector. After optimisation of MS conditions by flow injection analysis, selected ion monitoring detection was used to enhance sensitivity. The total Mtd concentration and the enantiomeric ratio in saliva were validated using an experimental design. The methods were applied to samples provided by heroin addicts undergoing a Mtd treatment. Results on total Mtd determination showed a very poor correlation between saliva and serum, whereas the enantiomeric ratios of Mtd gave a very good one.
Search on Google
Banco de datos:
MEDLINE
Asunto principal:
Saliva
/
Cromatografía Liquida
/
Metadona
Tipo de estudio:
Diagnostic_studies
Límite:
Humans
Idioma:
En
Año:
2000
Tipo del documento:
Article