Your browser doesn't support javascript.
loading
[Three-dimensional assessment of the remnant hepatic function following surgery using single photon emission computed tomography in an animal model].
Mao, Yi-lei; Zhang, Tao; Sang, Xin-ting; Li, Fang; Ba, Jian-tao; Lu, Xin; Yang, Zhi-ying; Zhong, Shou-xian; Huang, Jie-fu.
  • Mao YL; Department of Liver Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100730, China. maoy@public3.bta.net.cn
Zhonghua Wai Ke Za Zhi ; 45(9): 609-12, 2007 May 01.
Article en Zh | MEDLINE | ID: mdl-17688795
OBJECTIVE: The predictive value of postoperative hepatic function evaluated by liver functional imaging combined with single photon emission computed tomography (SPECT) technique was appraised in the present study. METHODS: Twenty New Zealand white rabbits were divided randomly into two groups, including the Hepatic Fibrosis with Carcinoma Group (FC-Group, n = 10) and the Control Group (C-Group, n = 10). All the rabbits underwent the resection of outer-right lobe of the liver. The whole hepatic function indexes, such as HCI(5), HLI(5) and Ex(15), and the hepatic function remnant indexes, including HCI(5P), HLI(5P) and Ex(15P), were calculated by 99mTc-EHIDA liver imaging. RESULTS: Ex(15) of FC-Group was lower than that of C-Group (P < 0.05). HCI(5) and HLI(5) of FC-Group had the trends to increase compared with the C-Group. Ex(15) was positively correlated with ALB, and negatively correlated with TBil and GGT (P < 0.05). HCI(5) had a positive correlation with CHE (P < 0.05), while HLI(5) had a negative correlation with A/G (P < 0.05). HLI(5P) had the negative correlation with postoperative A/G (P < 0.05), and Ex(15P) had the negative correlation with postoperative TBil and GGT (P < 0.05). CONCLUSIONS: This study has established a method of 3-D liver function evaluation system on an animal model. Among the indexes, Ex(15) can exactly represent the whole liver function while Ex(15P) and HLI(5P) can predict the liver function after the liver resection. The results may help the future clinical use of this technique to evaluate the risk of operation.
Asunto(s)
Search on Google
Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada de Emisión de Fotón Único / Hígado / Cirrosis Hepática Experimental / Neoplasias Hepáticas Experimentales Tipo de estudio: Prognostic_studies Límite: Animals Idioma: Zh Año: 2007 Tipo del documento: Article
Search on Google
Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada de Emisión de Fotón Único / Hígado / Cirrosis Hepática Experimental / Neoplasias Hepáticas Experimentales Tipo de estudio: Prognostic_studies Límite: Animals Idioma: Zh Año: 2007 Tipo del documento: Article