Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera-collimator combinations.
Eur J Nucl Med Mol Imaging
; 36(4): 560-6, 2009 Apr.
Article
en En
| MEDLINE
| ID: mdl-18989667
BACKGROUND: Although the heart-to-mediastinum (H/M) ratio in a planar image has been used for practical quantification in (123)I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of the H/M ratio could be standardized to the various camera-collimator combinations. METHODS AND RESULTS: Standard phantoms consisting of the heart and mediastinum were made. A low-energy high-resolution (LEHR) collimator and a medium-energy (ME) collimator were used. We examined multi-window correction methods with (123)I- dual-window (IDW) acquisition, and planar images were obtained with IDW correction and the LEHR collimator. The images were obtained using the following gamma camera systems: GCA 9300A (Toshiba, Tokyo), E.CAM Signature (Toshiba/Siemens, Tokyo) and Varicam (GE, Tokyo). Cardiac phantom studies demonstrated that contamination of the H/M count ratio was greater with the LEHR collimator and least with the ME collimator. The corrected H/M ratio with the LEHR collimator was similar to that with ME collimators. The uncorrected H/M ratio with the ME collimator was linearly related to the H/M ratio with IDW correction with the LEHR collimator. The relationship between the uncorrected H/M ratios determined with the LEHR (E.CAM) and the ME collimators was y = 0.56x + 0.49, where y = H/M ratio with the E.CAM and x = H/M ratio with the ME collimator. The average normal values for the low-energy collimator (n=18) were 2.2+/-0.2 (initial H/M ratio) and 2.42+/-0.2 (delayed H/M ratio), and for the low/medium-energy (LME) collimator (n=14) were 2.63+/-0.25 (initial H/M ratio) and 2.87+/-0.19 (delayed H/M ratio). H/M ratios in previous clinical studies using LEHR collimators are comparable to those with ME collimators. CONCLUSION: The IDW-corrected H/M ratios determined with the LEHR collimator were similar to those determined with the ME collimator. This finding could make it possible to standardize the H/M ratio in planar imaging among various collimators in the clinical setting.
Texto completo:
1
Banco de datos:
MEDLINE
Asunto principal:
Diagnóstico por Imagen
/
3-Yodobencilguanidina
/
Corazón
/
Radioisótopos de Yodo
/
Mediastino
Tipo de estudio:
Diagnostic_studies
/
Prognostic_studies
Idioma:
En
Año:
2009
Tipo del documento:
Article