Your browser doesn't support javascript.
loading
Quantification of etravirine (TMC125) in plasma, dried blood spots and peripheral blood mononuclear cell lysate by liquid chromatography tandem mass spectrometry.
Ter Heine, R; Rosing, H; van Gorp, E C M; Mulder, J W; Beijnen, J H; Huitema, A D R.
  • Ter Heine R; Department of Pharmacy and Pharmacology, Louwesweg 6, 1066EC Amsterdam, The Netherlands. rob.terheine@slz.nl
J Pharm Biomed Anal ; 49(2): 393-400, 2009 Feb 20.
Article en En | MEDLINE | ID: mdl-19059744
ABSTRACT
For the quantification of the novel non-nucleoside reverse transcriptase inhibitor etravirine in human plasma, dried blood spots and peripheral blood mononuclear cell (PBMC) lysate, an assay was developed and validated, using liquid chromatography coupled with tandem mass spectrometry. Etravirine was extracted from plasma by means of protein precipitation with a mixture of methanol and acetonitrile using only 50 microL plasma. Extraction from dried blood spots was performed with a one-step extraction with a mixture of methanol, acetonitrile and 0.2M zinc sulphate in water (112, v/v/v) and extraction from cell lysate was performed in 50% methanol in water. Chromatographic separation was performed on a reversed phase C18 column (150mmx2.0mm, particle size 5microm) with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.25mL/min. (13)C(6)-efavirenz was used as an internal standard. The analytical run time was only 10min. The triple quadrupole mass spectrometer was operated in the positive ion-mode and multiple reaction monitoring was used for drug quantification. The method was validated over a range of 25-5000ng/mL in plasma, 50-10,000ng/mL in dried blood spots and a range of 5-2500ng/mL in PBMC lysate. Accuracies ranged from 89% to 106% in plasma, from 94% to 109% in dried blood spots and from 91% to 105% in PBMC lysate. Precisions at the all concentration levels ranged from 1.9% to 14% in plasma, 4.7% to 20% in dried blood spots and from 3.1% to 11% in PBMC lysate. The bioanalytical assay was successfully incorporated with previously developed assays for the determination of all currently approved PIs and NNRTIs in plasma and dried blood spots and it is now applied for therapeutic drug monitoring and pharmacological research in HIV-infected patients treated with etravirine.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Piridazinas / Leucocitos Mononucleares / Inhibidores de la Proteasa del VIH / Desecación / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2009 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Piridazinas / Leucocitos Mononucleares / Inhibidores de la Proteasa del VIH / Desecación / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2009 Tipo del documento: Article