Your browser doesn't support javascript.
loading
Haemodynamic effects during endoscopic vein harvest of the saphenous vein for off-pump coronary artery bypass grafting surgery.
Kim, Seong-Hyop; Kim, Duk-Kyung; Yoon, Tae-Gyoon; Lim, Jeong-Ae; Woo, Nam-Sik; Kim, Tae-Yop.
  • Kim SH; Department of Anaesthesiology and Pain Medicine, School of Medicine, Konkuk University, Seoul, Korea.
Eur J Anaesthesiol ; 26(11): 969-73, 2009 Nov.
Article en En | MEDLINE | ID: mdl-19842243
ABSTRACT

OBJECTIVE:

Endoscopic vein harvest (EVH) for coronary artery bypass grafting surgery is performed with carbon dioxide (CO2) insufflation for visualization and dissection. The insufflated CO2 is rapidly absorbed into the body and may influence haemodynamics. However, the haemodynamic changes during EVH have not been clearly defined. This study evaluated the haemodynamic effects during EVH of the saphenous vein for off-pump coronary artery bypass grafting surgery (OPCAB).

METHODS:

After fixing the position for harvesting of the left internal mammary artery, EVH of the saphenous vein was performed at a maximum CO2 pressure of 12 mmHg and a flow of 3 l/min. The haemodynamic parameters were measured before and just after the end of endoscopic vein harvest.

RESULTS:

One hundred patients were studied. The end-tidal CO2 pressure (P(ET)CO2, 35.0 +/- 2.7 vs. 52.0 +/- 6.2 mmHg), partial pressure of arterial CO2 (PaCO2, 35.1 +/- 3.1 vs. 52.5 +/- 4.3 mmHg), mixed venous oxygen saturation (SvO2, 75.6 +/- 4.1 vs. 82.0 +/- 1.6%), cardiac index (2.7 +/- 0.6 vs. 3.3 +/- 0.6 l/min/m2), and cerebral oxygen saturation (ScO2, left 63.5 +/- 7.9 vs. 73.3 +/- 8.4; right 62.2 +/- 8.0 vs. 72.3 +/- 6.3%) differed significantly between before and after CO2 insufflation, whereas mean systemic blood pressure, mean pulmonary artery blood pressure, central venous pressure, heart rate, partial pressure of arterial oxygen, and peak inspiratory pressure did not differ significantly between before and after CO2 insufflation.

CONCLUSIONS:

EVH, at a maximum CO2 pressure of 12 mmHg and a flow of 3 l/min, of the saphenous vein for OPCAB was associated with hypercarbia and a tolerable range of hypercarbia (PaCO2 < 60 mmHg) increased the cardiac index and ScO2 without any complications.
Asunto(s)
Search on Google
Banco de datos: MEDLINE Asunto principal: Vena Safena / Dióxido de Carbono / Puente de Arteria Coronaria / Hemodinámica Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2009 Tipo del documento: Article
Search on Google
Banco de datos: MEDLINE Asunto principal: Vena Safena / Dióxido de Carbono / Puente de Arteria Coronaria / Hemodinámica Tipo de estudio: Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2009 Tipo del documento: Article