Comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry methods with conventional phenotypic identification for routine identification of bacteria to the species level.
Cherkaoui, Abdessalam; Hibbs, Jonathan; Emonet, Stéphane; Tangomo, Manuela; Girard, Myriam; Francois, Patrice; Schrenzel, Jacques.
  • Cherkaoui A; Clinical Microbiology Laboratory, Service of Infectious Diseases, University of Geneva Hospitals, CH-1211 Geneva 14, Switzerland. abdessalam.cherkaoui@hcuge.ch
J Clin Microbiol ; 48(4): 1169-75, 2010 Apr.
Article en En | MEDLINE | ID: mdl-20164271
ABSTRACT
Bacterial identification relies primarily on culture-based methodologies requiring 24 h for isolation and an additional 24 to 48 h for species identification. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is an emerging technology newly applied to the problem of bacterial species identification. We evaluated two MALDI-TOF MS systems with 720 consecutively isolated bacterial colonies under routine clinical laboratory conditions. Isolates were analyzed in parallel on both devices, using the manufacturers' default recommendations. We compared MS with conventional biochemical test system identifications. Discordant results were resolved with "gold standard" 16S rRNA gene sequencing. The first MS system (Bruker) gave high-confidence identifications for 680 isolates, of which 674 (99.1%) were correct; the second MS system (Shimadzu) gave high-confidence identifications for 639 isolates, of which 635 (99.4%) were correct. Had MS been used for initial testing and biochemical identification used only in the absence of high-confidence MS identifications, the laboratory would have saved approximately US$5 per isolate in marginal costs and reduced average turnaround time by more than an 8-h shift, with no loss in accuracy. Our data suggest that implementation of MS as a first test strategy for one-step species identification would improve timeliness and reduce isolate identification costs in clinical bacteriology laboratories now.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bacterias / Infecciones Bacterianas / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Tipo de estudio: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Límite: Humans Idioma: En Año: 2010 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bacterias / Infecciones Bacterianas / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Tipo de estudio: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Límite: Humans Idioma: En Año: 2010 Tipo del documento: Article