Your browser doesn't support javascript.
loading
An analysis of the bacterial community in a membrane bioreactor fed with photo-Fenton pre-treated toxic water.
Ballesteros Martín, M M; Garrido, L; Casas López, J L; Sánchez, O; Mas, J; Maldonado, M I; Sánchez Pérez, J A.
  • Ballesteros Martín MM; Department of Chemical Engineering, University of Almería, 04120 Almería, Spain.
J Ind Microbiol Biotechnol ; 38(9): 1171-8, 2011 Sep.
Article en En | MEDLINE | ID: mdl-21061043
ABSTRACT
A photo-Fenton-membrane bioreactor (MBR) coupled system is an innovative tool for the treatment of wastewater containing high quantities of contaminants. In this paper, wastewater with 200 mg l(-1) of dissolved organic carbon (DOC) of a selected mixture of five commercial pesticides Vydate®, Metomur®, Couraze®, Ditimur-40®, and Scala® was treated by combining photo-Fenton and MBR. The effect of photo-treated pollutants on MBR operation was investigated by studying the population changes that occurred with time in the activated sludge of the biological system. Pre-treatment with photo-Fenton was carried out (only up to 34% of mineralization of DOC) and, after MBR treatment, 98% of biodegradation efficiency was obtained. During the biological treatment, little changes in the activated sludge population were detected by DGGE analysis, maintaining acceptable biodegradation efficiency, which points out the robustness of the MBR treatment versus changes in feed composition.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bacterias / Contaminantes Químicos del Agua / Purificación del Agua / Reactores Biológicos Idioma: En Año: 2011 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Bacterias / Contaminantes Químicos del Agua / Purificación del Agua / Reactores Biológicos Idioma: En Año: 2011 Tipo del documento: Article