Your browser doesn't support javascript.
loading
A computational model of hemodynamic parameters in cortical capillary networks.
Safaeian, Navid; Sellier, Mathieu; David, Tim.
  • Safaeian N; Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Ilam St, Christchurch, New Zealand.
  • Sellier M; Department of Mechanical Engineering, University of Canterbury, Ilam St, Christchurch, New Zealand.
  • David T; Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Ilam St, Christchurch, New Zealand.
J Theor Biol ; 271(1): 145-56, 2011 Feb 21.
Article en En | MEDLINE | ID: mdl-21130099
The analysis of hemodynamic parameters and functional reactivity of cerebral capillaries is still controversial. To assess the hemodynamic parameters in the cortical capillary network, a generic model was created using 2D voronoi tessellation in which each edge represents a capillary segment. This method is capable of creating an appropriate generic model of cerebral capillary network relating to each part of the brain cortex because the geometric model is able to vary the capillary density. The modeling presented here is based on morphometric parameters extracted from physiological data of the human cortex. The pertinent hemodynamic parameters were obtained by numerical simulation based on effective blood viscosity as a function of hematocrit and microvessel diameter, phase separation and plasma skimming effects. The hemodynamic parameters of capillary networks with two different densities (consistent with the variation of the morphometric data in the human cortical capillary network) were analyzed. The results show pertinent hemodynamic parameters for each model. The heterogeneity (coefficient variation) and the mean value of hematocrits, flow rates and velocities of the both network models were specified. The distributions of blood flow throughout the both models seem to confirm the hypothesis in which all capillaries in a cortical network are recruited at rest (normal condition). The results also demonstrate a discrepancy of the network resistance between two models, which are derived from the difference in the number density of capillary segments between the models.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Capilares / Corteza Cerebral / Modelos Cardiovasculares Límite: Humans Idioma: En Año: 2011 Tipo del documento: Article