Your browser doesn't support javascript.
loading
A standardized measurement technique may improve the reliability of measurements of endometrial thickness and volume.
Martins, W P; Raine-Fenning, N J; Leite, S P; Ferriani, R A; Nastri, C O.
  • Martins WP; Departamento de Ginecologia e Obstetrícia da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo (FMRP-USP), Ribeirão Preto, Brazil. wpmartins@gmail.com
Ultrasound Obstet Gynecol ; 38(1): 107-15, 2011 Jul.
Article en En | MEDLINE | ID: mdl-21465609
ABSTRACT

OBJECTIVE:

To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra- and interobserver reliability and agreement with regard to endometrial measurement.

METHODS:

Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL(™)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A- and C-planes using subjective assessment.

RESULTS:

Endometrial volume measurements using the SMV and A-plane were more reliable (intra- and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra- and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra- and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or 'comparable' (50 and 53.3%, respectively), but never more difficult than using the C-plane.

CONCLUSIONS:

Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imagenología Tridimensional / Endometrio Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans Idioma: En Año: 2011 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imagenología Tridimensional / Endometrio Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans Idioma: En Año: 2011 Tipo del documento: Article