Your browser doesn't support javascript.
loading
The added value of apparent diffusion coefficient to cerebral blood volume in the preoperative grading of diffuse gliomas.
Hilario, A; Ramos, A; Perez-Nuñez, A; Salvador, E; Millan, J M; Lagares, A; Sepulveda, J M; Gonzalez-Leon, P; Hernandez-Lain, A; Ricoy, J R.
  • Hilario A; Department of Radiology, Hospital 12 de Octubre, Madrid, Spain. amayahilario@yahoo.es
AJNR Am J Neuroradiol ; 33(4): 701-7, 2012 Apr.
Article en En | MEDLINE | ID: mdl-22207304
ABSTRACT
BACKGROUND AND

PURPOSE:

In cerebral gliomas, rCBV correlates with tumor grade and histologic findings of vascular proliferation. Moreover, ADC assesses water diffusivity and is inversely correlated with tumor grade. In the present work, we have studied whether combined rCBV and ADC values improve the diagnostic accuracy of MR imaging in the preoperative grading of gliomas. MATERIALS AND

METHODS:

One hundred sixty-two patients with histopathologically confirmed diffuse gliomas underwent DWI and DSC. Mean rCBV and ADC values were compared among the tumor groups with the Student t test or ANOVA. ROC analysis was used to determine rCBV and ADC threshold values for glioma grading.

RESULTS:

rCBV had significantly different values between grade II and IV gliomas and between grade III and IV tumors, but there were no significant differences between grade II and III gliomas (P > .05). Grade II and III tumors also did not differ when astrocytomas, oligodendrogliomas, and oligoastrocytomas were considered separately. ADC values were significantly different for all 3 grades. The ADC threshold value of 1.185 × 10(-3) mm(2)/s and the rCBV cutoff value of 1.74 could be used with high sensitivity in the characterization of high-grade gliomas. The area under the ROC curve for the maximum rCBV and minimum ADC was 0.72 and 0.75, respectively. The combination of rCBV and ADC values increased the area under the ROC curve to 0.83.

CONCLUSIONS:

ADC measurements are better than rCBV values for distinguishing the grades of gliomas. The combination of minimum ADC and maximum rCBV improves the diagnostic accuracy of glioma grading.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Determinación del Volumen Sanguíneo / Neoplasias Encefálicas / Aumento de la Imagen / Angiografía por Resonancia Magnética / Imagen de Difusión por Resonancia Magnética / Glioma / Neovascularización Patológica Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2012 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Determinación del Volumen Sanguíneo / Neoplasias Encefálicas / Aumento de la Imagen / Angiografía por Resonancia Magnética / Imagen de Difusión por Resonancia Magnética / Glioma / Neovascularización Patológica Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2012 Tipo del documento: Article