Your browser doesn't support javascript.
loading
Volume-time curve: an alternative for endotracheal tube cuff management.
Bolzan, Douglas Willian; Gomes, Walter Jose; Faresin, Sônia Maria; de Camargo Carvalho, Antônio Carlos; De Paola, Angelo Amato Vincenzo; Guizilini, Solange.
  • Bolzan DW; Escola Paulista de Medicina, Federal University of São Paulo, São Paulo, Brazil.
Respir Care ; 57(12): 2039-44, 2012 Dec.
Article en En | MEDLINE | ID: mdl-22710636
ABSTRACT

BACKGROUND:

Despite numerous studies on endotracheal tube cuff pressure (CP) management, the literature has yet to establish a technique capable of adequately filling the cuff with an appropriate volume of air while generating low CP in a less subjective way. The purpose of this prospective study was to evaluate and compare the CP levels and air volume required to fill the endotracheal tubes cuff using 2 different techniques (volume-time curve versus minimal occlusive volume) in the immediate postoperative period after coronary artery bypass grafting.

METHODS:

A total of 267 subjects were analyzed. After the surgery, the lungs were ventilated using pressure controlled continuous mandatory ventilation, and the same ventilatory parameters were adjusted. Upon arrival in the ICU, the cuff was completely deflated and re-inflated, and at this point the volume of air to fill the cuff was adjusted using one of 2 randomly selected techniques volume-time curve and minimal occlusive volume. We measured the volume of air injected into the cuff, the CP, and the expired tidal volume of the mechanical ventilation after the application of each technique.

RESULTS:

The volume-time curve technique demonstrated a significantly lower CP and a lower volume of air injected into the cuff, compared to the minimal occlusive volume technique (P < .001). No significant difference was observed in the expired tidal volume between the 2 techniques (P = .052). However, when the subjects were submitted to the minimal occlusive volume technique, 17% (n = 47) experienced air leakage as observed by the volume-time graph.

CONCLUSIONS:

The volume-time curve technique was associated with a lower CP and a lower volume of air injected into the cuff, when compared to the minimal occlusive volume technique in the immediate postoperative period after coronary artery bypass grafting. Therefore, the volume-time curve may be a more reliable alternative for endotracheal tube cuff management.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Volumen de Ventilación Pulmonar / Intubación Intratraqueal Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2012 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Volumen de Ventilación Pulmonar / Intubación Intratraqueal Tipo de estudio: Clinical_trials / Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2012 Tipo del documento: Article