Your browser doesn't support javascript.
loading
The accuracy of different biopsy strategies for the detection of clinically important prostate cancer: a computer simulation.
Lecornet, Emilie; Ahmed, Hashim Uddin; Hu, Yipeng; Moore, Caroline M; Nevoux, Pierre; Barratt, Dean; Hawkes, David; Villers, Arnaud; Emberton, Mark.
  • Lecornet E; Service d'Urologie, Université Lille Nord de France, Institut national de la santé et de la recherche médicale, Loos, France.
J Urol ; 188(3): 974-80, 2012 Sep.
Article en En | MEDLINE | ID: mdl-22819118
ABSTRACT

PURPOSE:

The true accuracy of different biopsy strategies for detecting clinically significant prostate cancer is unknown, given the positive evaluation bias required for verification by radical prostatectomy. To evaluate how well different biopsy strategies perform at detecting clinically significant prostate cancer we used computer simulation in cystoprostatectomy cases with cancer. MATERIALS AND

METHODS:

A computer simulation study was performed on prostates acquired at radical cystoprostatectomy. A total of 346 prostates were processed and examined for prostate cancer using 3 mm whole mount slices. The 96 prostates that contained cancer were digitally reconstructed. Biopsy simulations incorporating various degrees of random localization error were performed using the reconstructed 3-dimensional prostate computer model. Each biopsy strategy was simulated 500 times. Two definitions of clinically significant prostate cancer were used to define the reference standard, including definition 1--Gleason score 7 or greater, and/or lesion volume 0.5 ml or greater and definition 2--Gleason score 7 or greater, and/or lesion volume 0.2 ml or greater.

RESULTS:

A total of 215 prostate cancer foci were present. The ROC AUC to detect and rule out definition 1 prostate cancer was 0.69, 0.75, 0.82 and 0.91 for 12-core transrectal ultrasound biopsy with a random localization error of 15 and 10 mm, 14-core transrectal ultrasound biopsy and template prostate mapping using a 5 mm sampling frame, respectively.

CONCLUSIONS:

To our knowledge our biopsy simulation study is the first to evaluate the performance of different sampling strategies to detect clinically important prostate cancer in a population that better reflects the demographics of a screened cohort. Compared to other strategies standard transrectal ultrasound biopsy performs poorly for detecting clinically important cancer. Marginal improvement can be achieved using additional cores placed anterior but the performance attained by template prostate mapping is optimal.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Biopsia con Aguja / Simulación por Computador Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans / Male Idioma: En Año: 2012 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Biopsia con Aguja / Simulación por Computador Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans / Male Idioma: En Año: 2012 Tipo del documento: Article