[Diagnosis of Down's syndrome using short tandem repeat loci D21S11, D21S1440 and Penta D].
Zhonghua Yi Xue Yi Chuan Xue Za Zhi
; 29(4): 443-6, 2012 Aug.
Article
en Zh
| MEDLINE
| ID: mdl-22875503
OBJECTIVE: To investigate the feasibility of genetic diagnosis of Down's syndrome (DS) using short tandem repeat (STR), and to develop a rapid and accurate method for diagnosing DS. METHODS: Quantitative fluorescence polymerase chain reaction (QF-PCR) was used to amplify STR loci D21S11, D21S1440 and Penta D of 719 samples. Three hundred and eighty-nine samples were peripheral blood, 282 were amniotic fluid, 48 were chorionic villous samples. The products were analyzed using eleterophoresis to detect DS. RESULTS: Among 652 samples with a normal karyotype, 635 showed 2 bands with a 1:1 ratio or a single band. The remaining 17 samples showed 3 bands, and were regarded as false positive results. For 67 DS samples, 53 showed 3 bands/peaks with a 1:1:1 ratio and 14 showed 2 bands/peaks with a 2:1 ratio. The sensitivity and specificity of STR loci D21S11, D21S1440 and Penta D were 76.12% and 98.62%, 71.64% and 98.93%, 89.55% and 99.85%, respectively. The overall sensitivity and specificity of 3 STR loci were 100% (67/67) and 97.39% (635/652), respectively. CONCLUSION: Compared with conventional method, author's method is simpler, more stable and rapid, and can be used for large-scale prenatal screening of DS.
Texto completo:
1
Banco de datos:
MEDLINE
Asunto principal:
Diagnóstico Prenatal
/
Síndrome de Down
/
Repeticiones de Microsatélite
Tipo de estudio:
Diagnostic_studies
Límite:
Female
/
Humans
/
Pregnancy
Idioma:
Zh
Año:
2012
Tipo del documento:
Article