Your browser doesn't support javascript.
loading
A sensitivity analysis of a personalized pulse wave propagation model for arteriovenous fistula surgery. Part B: Identification of possible generic model parameters.
Huberts, W; de Jonge, C; van der Linden, W P M; Inda, M A; Passera, K; Tordoir, J H M; van de Vosse, F N; Bosboom, E M H.
  • Huberts W; Eindhoven University of Technology, Department of Biomedical Engineering, The Netherlands. w.huberts@tue.nl
Med Eng Phys ; 35(6): 827-37, 2013 Jun.
Article en En | MEDLINE | ID: mdl-22964064
ABSTRACT
Decision-making in vascular access surgery for hemodialysis can be supported by a pulse wave propagation model that is able to simulate pressure and flow changes induced by the creation of a vascular access. To personalize such a model, patient-specific input parameters should be chosen. However, the number of input parameters that can be measured in clinical routine is limited. Besides, patient data are compromised with uncertainty. Incomplete and uncertain input data will result in uncertainties in model predictions. In part A, we analyzed how the measurement uncertainty in the input propagates to the model output by means of a sensitivity analysis. Of all 73 input parameters, 16 parameters were identified to be worthwhile to measure more accurately and 51 could be fixed within their measurement uncertainty range, but these latter parameters still needed to be measured. Here, we present a methodology for assessing the model input parameters that can be taken constant and therefore do not need to be measured. In addition, a method to determine the value of this parameter is presented. For the pulse wave propagation model applied to vascular access surgery, six patient-specific datasets were analyzed and it was found that 47 out of 73 parameters can be fixed on a generic value. These model parameters are not important for personalization of the wave propagation model. Furthermore, we were able to determine a generic value for 37 of the 47 fixable model parameters.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Derivación Arteriovenosa Quirúrgica / Medicina de Precisión / Análisis de la Onda del Pulso / Modelos Biológicos Tipo de estudio: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies Límite: Humans Idioma: En Año: 2013 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Derivación Arteriovenosa Quirúrgica / Medicina de Precisión / Análisis de la Onda del Pulso / Modelos Biológicos Tipo de estudio: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies Límite: Humans Idioma: En Año: 2013 Tipo del documento: Article