Your browser doesn't support javascript.
loading
Late type III endoleak from fabric tears of a zenith stent graft: report of a case.
Banno, Hiroshi; Morimae, Hirofumi; Ihara, Tsutomu; Kobayashi, Masayoshi; Yamamoto, Kiyohito; Komori, Kimihiro.
  • Banno H; Division of Vascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya 466-8550, Japan. hbanno@med.nagoya-u.ac.jp
Surg Today ; 42(12): 1206-9, 2012 Dec.
Article en En | MEDLINE | ID: mdl-22975799
We report a case of late type III B endoleak from a fabric tear in the main body of a Zenith bifurcated stent-graft approximately 19 months after implantation. A follow-up computed tomography (CT) scan showed gradual growth in the size of the aneurysm, but no apparent endoleak was recognized. However, the CT scan had demonstrated a mosaic pattern in the aneurysm sac, which could indicate an endoleak from a fabric tear. The defect was repaired by implantation of body extensions, but the patient died 5 h after the procedure.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Falla de Prótesis / Prótesis Vascular / Aneurisma de la Aorta Abdominal / Endofuga Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged80 / Humans / Male Idioma: En Año: 2012 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Falla de Prótesis / Prótesis Vascular / Aneurisma de la Aorta Abdominal / Endofuga Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged80 / Humans / Male Idioma: En Año: 2012 Tipo del documento: Article