Your browser doesn't support javascript.
loading
A novel homogeneous time-resolved fluoroimmunoassay for carcinoembryonic antigen based on water-soluble quantum dots.
Chen, Zhen-Hua; Wu, Ying-Song; Chen, Mei-Jun; Hou, Jing-Yuan; Ren, Zhi-Qi; Sun, Da; Liu, Tian-Cai.
  • Chen ZH; School of Biotechnology, Southern Medical University, Guangzhou, 510515, Guangdong, People's Republic of China.
J Fluoresc ; 23(4): 649-57, 2013 Jul.
Article en En | MEDLINE | ID: mdl-23471623
ABSTRACT
Quantum dots are not widely used in clinical diagnosis. However, the homogeneous time-resolved fluorescence assay possesses many advantages over current methods for the detection of carcinoembryonic antigen (CEA), a primary marker for many cancers and diseases. Therefore, a novel luminescent terbium chelates- (LTCs) and quantum dots-based homogeneous time-resolved fluorescence assay was developed to detect CEA. Glutathione-capped quantum dots (QDs) were prepared from oil-soluble QDs with a 565 nm emission peak. Conjugates (QDs-6 F11) were prepared with QDs and anti-CEA monoclonal antibody. LTCs were prepared and conjugates (LTCs-S001) were prepared with another anti-CEA monoclonal antibody. The fluorescence lifetime of QDs was optimized for sequential analysis. The Förster distance (R0) was calculated as 61.9 Å based on the overlap of the spectra of QDs-6 F11 and LTCs-S001. Using a double-antibody sandwich approach, the above antibody conjugates were used as energy acceptor and donor, respectively. The signals from QDs were collected in time-resolved mode and analyzed for the detection of CEA. The results show that the QDs were suitable for time-resolved fluoroassays. The spatial distance of the donor-acceptor pair was calculated to be 61.9 Å. The signals from QDs were proportional to CEA concentration. The standard curve was LogY = 2.75566 + 0.94457 LogX (R = 0.998) using the fluorescence counts (Y) of QDs and the concentrations of CEA (X). The calculated sensitivity was 0.4 ng/mL. The results indicate that water-soluble QDs are suitable for the homogenous immunoassay. This work has expanded future applications of QDs in homogeneous clinical bioassays. Furthermore, a QDs-based homogeneous multiplex immunoassay will be investigated as a biomarker for infectious diseases in future research.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Agua / Fluoroinmunoensayo / Antígeno Carcinoembrionario / Puntos Cuánticos Límite: Animals Idioma: En Año: 2013 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Agua / Fluoroinmunoensayo / Antígeno Carcinoembrionario / Puntos Cuánticos Límite: Animals Idioma: En Año: 2013 Tipo del documento: Article