Your browser doesn't support javascript.
loading
Circumferential guided wave measurements of a cylindrical fluid-filled bone-mimicking phantom.
Nauleau, Pierre; Grimal, Quentin; Minonzio, Jean-Gabriel; Laugier, Pascal; Prada, Claire.
  • Nauleau P; Sorbonne Universités, UPMC Univ Paris 06, UMR 7623, Laboratoire d'Imagerie Paramétrique, F-75005, Paris, France.
  • Grimal Q; Sorbonne Universités, UPMC Univ Paris 06, UMR 7623, Laboratoire d'Imagerie Paramétrique, F-75005, Paris, France.
  • Minonzio JG; Sorbonne Universités, UPMC Univ Paris 06, UMR 7623, Laboratoire d'Imagerie Paramétrique, F-75005, Paris, France.
  • Laugier P; Sorbonne Universités, UPMC Univ Paris 06, UMR 7623, Laboratoire d'Imagerie Paramétrique, F-75005, Paris, France.
  • Prada C; Institut Langevin, Ecole Superieure de Physique et de Chimie Industrielles Paris Tech, Universite Denis Diderot Paris 7, CNRS 7587, 1 rue Jussieu, F-75005 Paris, France.
J Acoust Soc Am ; 135(2): 994-1001, 2014 Feb.
Article en En | MEDLINE | ID: mdl-25234906
ABSTRACT
In the context of hip fracture risk prediction, measurement of guided waves could improve the assessment of cortical femoral neck properties. The decomposition of the time reversal operator (DORT) method was previously shown to be efficient to measure circumferential guided modes in an empty cortical bone-mimicking tube of circular cross section. In this study, an adaptation of the DORT method is proposed to probe the same bone-mimicking tube but filled with a marrow-mimicking fluid. The contributions to the backscattered field of waves multiply reflected in the cavity of the tube interfere with those of circumferential guided waves. The former contributions are eliminated in the backpropagation image using ad hoc criterion determined with simulation. Eight portions of different guided modes were observed from experimental and simulated data. They were identified by comparison with theoretical predictions. This work confirms the feasibility of measuring guided waves in a fluid-filled tube of bone-mimicking material with the DORT method.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ultrasonido / Fantasmas de Imagen / Cuello Femoral Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Año: 2014 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ultrasonido / Fantasmas de Imagen / Cuello Femoral Tipo de estudio: Diagnostic_studies / Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Año: 2014 Tipo del documento: Article