Your browser doesn't support javascript.
loading
Potential effects of polychlorinated biphenyls (PCBs) and selected organochlorine pesticides (OCPs) on immune cells and blood biochemistry measures: a cross-sectional assessment of the NHANES 2003-2004 data.
Serdar, Berrin; LeBlanc, William G; Norris, Jill M; Dickinson, L Miriam.
  • Serdar B; Environmental and Occupational Health Department, Colorado School of Public Health, University of Colorado Denver, Colorado, Denver, USA. Berrin.Serdar@ucdenver.edu.
Environ Health ; 13: 114, 2014 Dec 16.
Article en En | MEDLINE | ID: mdl-25515064
ABSTRACT

BACKGROUND:

Polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) are widely distributed in the environment and may have adverse effects on the immune system.

METHODS:

Lipid adjusted serum levels of 19 Dioxin Like (DL), 17 Non Dioxin Like (NDL) PCBs, 5 OCPs, and measures of complete blood count and routine biochemistry profile were obtained from the NHANES 2003-2004 cycle. For each of the PCB/OCP variables, individuals were put into four exposure groups and blood markers were compared across these groups.

RESULTS:

Serum levels of PCBs and OCPs increased with age. Total white blood cell (WBC) count, red blood cells (RBC), hemoglobin, and hematocrit measures were lowest in the group with the highest serum PCBs. Results for the OCPs varied. For Mirex, WBC declined in the highest exposure; no significant differences were observed for p-p'-DDT or p-p'-DDE; and higher levels of WBC were observed at the highest exposure groups of serum trans-nonachlor and oxychlordane. Liver enzymes (AST, ALT, and GGT) were significantly higher in the highest exposure groups of PCBs/OCPs.

CONCLUSIONS:

We observed significant associations between PCB/OCP levels and blood markers in the general population. All of the levels were within normal ranges but the consistency of results is remarkable and may reflect subclinical effects. Largest differences were observed for NDL PCBs. Thus, routine application of toxic equivalency factors, which assume dioxin like mechanisms and aryl hydrocarbon receptor involvement, may not adequately reflect the effects of NDL PCBs in the mixture.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Plaguicidas / Hidrocarburos Clorados Tipo de estudio: Prevalence_studies / Risk_factors_studies Límite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Año: 2014 Tipo del documento: Article