Your browser doesn't support javascript.
loading
The impact of early pelvic and lower limb reperfusion and attentive peri-operative management on the incidence of spinal cord ischemia during thoracoabdominal aortic aneurysm endovascular repair.
Maurel, B; Delclaux, N; Sobocinski, J; Hertault, A; Martin-Gonzalez, T; Moussa, M; Spear, R; Le Roux, M; Azzaoui, R; Tyrrell, M; Haulon, S.
  • Maurel B; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Delclaux N; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Sobocinski J; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Hertault A; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Martin-Gonzalez T; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Moussa M; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Spear R; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Le Roux M; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Azzaoui R; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France.
  • Tyrrell M; King's Health Partners, London, UK.
  • Haulon S; Aortic Centre, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France. Electronic address: stephan.haulon@chru-lille.fr.
Eur J Vasc Endovasc Surg ; 49(3): 248-54, 2015 Mar.
Article en En | MEDLINE | ID: mdl-25575833
ABSTRACT
OBJECTIVE/

BACKGROUND:

Spinal cord ischemia (SCI) is a devastating complication following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. In an attempt to reduce its incidence two peri-procedural changes were implemented by the authors in January 2010 (i) all large sheaths are withdrawn from the iliac arteries immediately after deploying the central device and before cannulation and branch extension to the visceral vessels; (ii) the peri-operative protocol has been modified in an attempt to optimize oxygen delivery to the sensitive cells of the cord (aggressive blood and platelet transfusion, median arterial pressure monitoring >85 mmHg, and systematic cerebrospinal fluid drainage).

METHODS:

Between October 2004 and December 2013, 204 endovascular TAAA repairs were performed using custom made devices manufactured with branches and fenestrations to maintain visceral vessel perfusion. Data from all of these procedures were prospectively collected in an electronic database. Early post-operative results in patients treated before (group 1, n = 43) and after (group 2, n = 161 patients) implementation of the modified implantation and peri-operative protocols were compared.

RESULTS:

Patients in groups 1 and 2 had similar comorbidities (median age at repair 70.9 years [range 65.2-77.0 years]), aneurysm characteristics (median diameter 58.5 mm [range 53-65 mm]), and length of procedure (median 190 minutes [range 150-240 minutes]). The 30 day mortality rate was 11.6% in group 1 versus 5.6% in group 2 (p = .09). The SCI rate was 14.0% versus 1.2% (p < .01). If type IV TAAAs were excluded from this analysis, the SCI rate was 25.0% (6/24 patients) in group 1 versus 2.1% (2/95 patients) in group 2 (p < .01).

CONCLUSION:

The early restoration of arterial flow to the pelvis and lower limbs, and aggressive peri-operative management significantly reduces SCI following type I-III TAAA endovascular repair. With the use of these modified protocols, extensive TAAA endovascular repairs are associated with low rates of SCI.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Pelvis / Aneurisma de la Aorta Torácica / Implantación de Prótesis Vascular / Isquemia de la Médula Espinal / Extremidad Inferior / Procedimientos Endovasculares Tipo de estudio: Clinical_trials / Diagnostic_studies / Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged País como asunto: Europa Idioma: En Año: 2015 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Pelvis / Aneurisma de la Aorta Torácica / Implantación de Prótesis Vascular / Isquemia de la Médula Espinal / Extremidad Inferior / Procedimientos Endovasculares Tipo de estudio: Clinical_trials / Diagnostic_studies / Etiology_studies / Incidence_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged País como asunto: Europa Idioma: En Año: 2015 Tipo del documento: Article