Your browser doesn't support javascript.
loading
Rapid and sensitive detection of multiple microRNAs in cell lysate by low-fouling surface plasmon resonance biosensor.
Vaisocherová, Hana; Sípová, Hana; Vísová, Ivana; Bocková, Markéta; Springer, Tomás; Ermini, Maria Laura; Song, Xue; Krejcík, Zdenek; Chrastinová, Leona; Pastva, Ondrej; Pimková, Kristýna; Dostálová Merkerová, Michaela; Dyr, Jan E; Homola, Jirí.
  • Vaisocherová H; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Sípová H; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Vísová I; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Bocková M; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Springer T; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Ermini ML; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Song X; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic.
  • Krejcík Z; Institute of Hematology and Blood Transfusion, U Nemocnice 1, 12820 Prague, Czech Republic.
  • Chrastinová L; Institute of Hematology and Blood Transfusion, U Nemocnice 1, 12820 Prague, Czech Republic.
  • Pastva O; Institute of Hematology and Blood Transfusion, U Nemocnice 1, 12820 Prague, Czech Republic.
  • Pimková K; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic; Institute of Hematology and Blood Transfusion, U Nemocnice 1, 12820 Prague, Czech Republic.
  • Dostálová Merkerová M; Institute of Hematology and Blood Transfusion, U Nemocnice 1, 12820 Prague, Czech Republic.
  • Dyr JE; Institute of Hematology and Blood Transfusion, U Nemocnice 1, 12820 Prague, Czech Republic.
  • Homola J; Institute of Photonics and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic. Electronic address: homola@ufe.cz.
Biosens Bioelectron ; 70: 226-31, 2015 Aug 15.
Article en En | MEDLINE | ID: mdl-25829219
ABSTRACT
We report an ultra-low fouling surface plasmon resonance imaging (SPRi) biosensor for the rapid simultaneous detection of multiple miRNAs in erythrocyte lysate (EL) at subpicomolar levels without need of RNA extraction. The SPRi chips were coated with ultra-low fouling functionalizable poly(carboxybetaine acrylamide) (pCBAA) brushes having optimized thicknesses and directly functionalized with amino-modified oligonucleotide probes. We have characterized the effect of the brush thickness on the probe loading capacity a loading capacity of ~9.8×10(12) probes/cm(2) was achieved for pCBAA having a thickness of ~40 nm. The probe-functionalized sensor also exhibited a high resistance to fouling from ~90% EL samples (<2 ng/cm(2)). A two-step detection assay was employed for multiplexed miRNA detection in EL. Specifically, the assay consisted of (i) a sandwich-type hybridization of the probe-functionalized pCBAA with target miRNA in EL (bound to biotinylated oligonucleotides) and (ii) the capture of streptavidin-functionalized gold nanoparticles to the aforementioned biotinylated probes. We have demonstrated that this approach enables the detection of miRNAs in EL at concentrations as low as 0.5 pM. Finally, we have confirmed the detection of four endogenous miRNAs representing a set of potential miRNA biomarkers of myelodysplastic syndrome (MDS) in clinical EL samples (miR-16, miR-181, miR-34a, and miR-125b). The results revealed significantly higher levels of miR-16 in all the clinical EL samples compared to the other measured miRNAs.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Polímeros / Acrilamidas / Técnicas Biosensibles / Resonancia por Plasmón de Superficie / MicroARNs Tipo de estudio: Diagnostic_studies Idioma: En Año: 2015 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Polímeros / Acrilamidas / Técnicas Biosensibles / Resonancia por Plasmón de Superficie / MicroARNs Tipo de estudio: Diagnostic_studies Idioma: En Año: 2015 Tipo del documento: Article