Your browser doesn't support javascript.
loading
Automated removal of spurious intermediate cerebral blood flow volumes improves image quality among older patients: A clinical arterial spin labeling investigation.
Shirzadi, Zahra; Crane, David E; Robertson, Andrew D; Maralani, Pejman J; Aviv, Richard I; Chappell, Michael A; Goldstein, Benjamin I; Black, Sandra E; MacIntosh, Bradley J.
  • Shirzadi Z; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
  • Crane DE; HSF Canadian Partnership for Stroke Recovery, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Robertson AD; HSF Canadian Partnership for Stroke Recovery, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Maralani PJ; HSF Canadian Partnership for Stroke Recovery, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Aviv RI; Brain Sciences Research Program, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Chappell MA; Division of Neuroradiology, Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada.
  • Goldstein BI; Brain Sciences Research Program, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Black SE; Division of Neuroradiology, Department of Medical Imaging, University of Toronto, Toronto, Ontario, Canada.
  • MacIntosh BJ; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK.
J Magn Reson Imaging ; 42(5): 1377-85, 2015 Nov.
Article en En | MEDLINE | ID: mdl-25873287
PURPOSE: To evaluate the impact of rejecting intermediate cerebral blood flow (CBF) images that are adversely affected by head motion during an arterial spin labeling (ASL) acquisition. MATERIALS AND METHODS: Eighty participants were recruited, representing a wide age range (14-90 years) and heterogeneous cerebrovascular health conditions including bipolar disorder, chronic stroke, and moderate to severe white matter hyperintensities of presumed vascular origin. Pseudocontinuous ASL and T1 -weigthed anatomical images were acquired on a 3T scanner. ASL intermediate CBF images were included based on their contribution to the mean estimate, with the goal to maximize CBF detectability in gray matter (GM). Simulations were conducted to evaluate the performance of the proposed optimization procedure relative to other ASL postprocessing approaches. Clinical CBF images were also assessed visually by two experienced neuroradiologists. RESULTS: Optimized CBF images (CBFopt ) had significantly greater agreement with a synthetic ground truth CBF image and greater CBF detectability relative to the other ASL analysis methods (P < 0.05). Moreover, empirical CBFopt images showed a significantly improved signal-to-noise ratio relative to CBF images obtained from other postprocessing approaches (mean: 12.6%; range 1% to 56%; P < 0.001), and this improvement was age-dependent (P = 0.03). Differences between CBF images from different analysis procedures were not perceptible by visual inspection, while there was a moderate agreement between the ratings (κ = 0.44, P < 0.001). CONCLUSION: This study developed an automated head motion threshold-free procedure to improve the detection of CBF in GM. The improvement in CBF image quality was larger when considering older participants.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Trastorno Bipolar / Procesamiento de Imagen Asistido por Computador / Encéfalo / Imagen por Resonancia Magnética / Circulación Cerebrovascular / Trastornos Cerebrovasculares Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Año: 2015 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Trastorno Bipolar / Procesamiento de Imagen Asistido por Computador / Encéfalo / Imagen por Resonancia Magnética / Circulación Cerebrovascular / Trastornos Cerebrovasculares Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Año: 2015 Tipo del documento: Article