ABSTRACT

OBJECTIVE:

To establish standardized methods and parameters of the isolated heart coronary angiography through the experiment of in vitro porcine heart by MSCT.

METHODS:

Based on different perfusion volume (50, 60 and 70 mL) and different perfusion-imaging time (5, 10 and 20 min), the in vitro porcine coronary artery was injected liposoluble and water-soluble contrast agents using remodel angiography equipment and scanned by MSCT. And the 3D image results were compared. The images were recorded and evaluated by 2 radiologists and analyzed by statistical software.

RESULTS:

Liposoluble contrast agent affected the images by damaging and infiltrating the fats around the coronary artery, while the water-soluble contrast agent didn't affect the images. The groups with 60 mL or 70 mL perfusion and 5 min perfusion-imaging time had the best images.

CONCLUSION:

The suitable parameters of the angiography lay the foundation of postmortem coronary angiography.