Certification of Total Arsenic in Blood and Urine Standard Reference Materials by Radiochemical Neutron Activation Analysis and Inductively Coupled Plasma - Mass Spectrometry.
Paul, Rick L; Davis, W Clay; Yu, Lee; Murphy, Karen E; Guthrie, William F; Leber, Dennis D; Bryan, Colleen E; Vetter, Thomas W; Shakirova, Gulchekhra; Mitchell, Graylin; Kyle, David J; Jarrett, Jeffery M; Caldwell, Kathleen L; Jones, Robert L; Eckdahl, Steven; Wermers, Michelle; Maras, Melissa; Palmer, C D; Verostek, M F; Geraghty, C M; Steuerwald, Amy J; Parsons, Patrick J.
  • Paul RL; Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Davis WC; Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Yu L; Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Murphy KE; Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Guthrie WF; Statistical Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Leber DD; Statistical Engineering Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Bryan CE; Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Vetter TW; Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899.
  • Shakirova G; Inorganic and Radiation Analytical Toxicology Branch, Centers for Disease Control and Prevention, Atlanta, GA 30341.
  • Mitchell G; Inorganic and Radiation Analytical Toxicology Branch, Centers for Disease Control and Prevention, Atlanta, GA 30341.
  • Kyle DJ; Inorganic and Radiation Analytical Toxicology Branch, Centers for Disease Control and Prevention, Atlanta, GA 30341.
  • Jarrett JM; Inorganic and Radiation Analytical Toxicology Branch, Centers for Disease Control and Prevention, Atlanta, GA 30341.
  • Caldwell KL; Inorganic and Radiation Analytical Toxicology Branch, Centers for Disease Control and Prevention, Atlanta, GA 30341.
  • Jones RL; Inorganic and Radiation Analytical Toxicology Branch, Centers for Disease Control and Prevention, Atlanta, GA 30341.
  • Eckdahl S; Mayo Clinic, Rochester, MN 55905.
  • Wermers M; Mayo Clinic, Rochester, MN 55905.
  • Maras M; Mayo Clinic, Rochester, MN 55905.
  • Palmer CD; Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health (NYSDOH), Albany, NY 12201-0509.
  • Verostek MF; Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health (NYSDOH), Albany, NY 12201-0509.
  • Geraghty CM; Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health (NYSDOH), Albany, NY 12201-0509.
  • Steuerwald AJ; Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health (NYSDOH), Albany, NY 12201-0509.
  • Parsons PJ; Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health (NYSDOH), Albany, NY 12201-0509 ; Dept of Environmental Health Sciences, School of Public Health, University at Albany, 12201-0509.
J Radioanal Nucl Chem ; 299(3): 1555-1563, 2014 Mar.
Article en En | MEDLINE | ID: mdl-26300575
ABSTRACT
A newly developed procedure for determination of arsenic by radiochemical neutron activation analysis (RNAA) was used to measure arsenic at four levels in SRM 955c Toxic Elements in Caprine Blood and at two levels in SRM 2668 Toxic Elements in Frozen Human Urine for the purpose of providing mass concentration values for certification. Samples were freeze-dried prior to analysis followed by neutron irradiation for 3 h at a fluence rate of 1×1014cm-2s-1. After sample dissolution in perchloric and nitric acids, arsenic was separated from the matrix by extraction into zinc diethyldithiocarbamate in chloroform, and 76As quantified by gamma-ray spectroscopy. Differences in chemical yield and counting geometry between samples and standards were monitored by measuring the count rate of a 77As tracer added before sample dissolution. RNAA results were combined with inductively coupled plasma - mass spectrometry (ICP-MS) values from NIST and collaborating laboratories to provide certified values of (10.81 ± 0.54) µg/kg and (213.1 ± 0.73) µg/kg for SRM 2668 Levels I and II, and certified values of (21.66 ± 0.73) µg/kg, (52.7 ± 1.1) µg/kg, and (78.8 ± 4.9) µg/kg for SRM 955c Levels 2, 3, and 4 respectively. Because of discrepancies between values obtained by different methods for SRM 955c Level 1, an information value of < 5 µg/kg was assigned for this material.