Terminal decontamination of the Royal Free London's high-level isolation unit after a case of Ebola virus disease using hydrogen peroxide vapor.
Otter, Jonathan A; Mepham, Stephen; Athan, Breda; Mack, Damien; Smith, Robin; Jacobs, Michael; Hopkins, Susan.
  • Otter JA; Centre for Clinical Infection and Diagnostics Research, Department of Infectious Diseases, King's College London & Guy's and St. Thomas' NHS Foundation Trust, London, UK; Bioquell UK, Andover, UK.
  • Mepham S; Division of Infectious Diseases and Microbiology, Royal Free London NHS Foundation Trust, London, UK.
  • Athan B; Division of Infectious Diseases and Microbiology, Royal Free London NHS Foundation Trust, London, UK.
  • Mack D; Division of Infectious Diseases and Microbiology, Royal Free London NHS Foundation Trust, London, UK.
  • Smith R; Division of Infectious Diseases and Microbiology, Royal Free London NHS Foundation Trust, London, UK.
  • Jacobs M; Division of Infectious Diseases and Microbiology, Royal Free London NHS Foundation Trust, London, UK.
  • Hopkins S; Division of Infectious Diseases and Microbiology, Royal Free London NHS Foundation Trust, London, UK. Electronic address: susanhopkins@nhs.net.
Am J Infect Control ; 44(2): 233-5, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26521699
ABSTRACT
We report the decontamination of the high-level isolation unit at the Royal Free London after the discharge of a patient with Ebola virus disease, who was repatriated from West Africa. Hydrogen peroxide vapor (HPV) was used to decontaminate the patient care isolators and the rooms housing them. HPV decontamination was completed without incident and allowed the unit to be returned to service more quickly than the previous protocol of using formaldehyde.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aisladores de Pacientes / Infección Hospitalaria / Control de Infecciones / Fiebre Hemorrágica Ebola / Ebolavirus / Peróxido de Hidrógeno Límite: Humans País como asunto: Europa Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Aisladores de Pacientes / Infección Hospitalaria / Control de Infecciones / Fiebre Hemorrágica Ebola / Ebolavirus / Peróxido de Hidrógeno Límite: Humans País como asunto: Europa Idioma: En Año: 2016 Tipo del documento: Article