Your browser doesn't support javascript.
loading
Using the Human Activity Profile to Assess Functional Performance in Heart Failure.
Ribeiro-Samora, Giane Amorim; Pereira, Danielle Aparecida Gomes; Vieira, Otávia Alves; de Alencar, Maria Clara Noman; Rodrigues, Roseane Santo; Carvalho, Maria Luiza Vieira; Montemezzo, Dayane; Britto, Raquel Rodrigues.
  • Ribeiro-Samora GA; Rehabilitation Sciences Graduate Program (Drs Ribeiro-Samora, Pereira, and Britto and Mss Vieira, Rodrigues, Carvalho, and Montemezzo), Department of Physical Therapy (Drs Pereira and Britto), and Division of Cardiology and Cardiovascular Surgery, University Hospital (Ms de Alencar), Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
J Cardiopulm Rehabil Prev ; 36(3): 180-5, 2016.
Article en En | MEDLINE | ID: mdl-26784733
PURPOSE: To investigate (1) the validity of using the Human Activity Profile (HAP) in patients with heart failure (HF) to estimate functional capacity; (2) the association between the HAP and 6-Minute Walk Test (6MWT) distance; and (3) the ability of the HAP to differentiate between New York Heart Association (NYHA) functional classes. METHODS: In a cross-sectional study, we evaluated 62 clinically stable patients with HF (mean age, 47.98 years; NYHA class I-III). Variables included maximal functional capacity as measured by peak oxygen uptake ((Equation is included in full-text article.)O2) using a cardiopulmonary exercise test (CPET), peak (Equation is included in full-text article.)O2 as estimated by the HAP, and exercise capacity as measured by the 6MWT. RESULTS: The difference between the measured (CPET) and estimated (HAP) peak (Equation is included in full-text article.)O2 against the average values showed a bias of 2.18 mL/kg/min (P = .007). No agreement was seen between these measures when applying the Bland-Altman method. Peak (Equation is included in full-text article.)O2 in the HAP showed a moderate association with the 6MWT distance (r = 0.62; P < .0001). Peak (Equation is included in full-text article.)O2 in the HAP was able to statistically differentiate NYHA functional classes I, II, and III (P < .05). CONCLUSIONS: The estimated peak (Equation is included in full-text article.)O2 using the HAP was not concordant with the gold standard CPET measure. On the contrary, the HAP was able to differentiate NYHA functional class associated with the 6MWT distance; therefore, the HAP is a useful tool for assessing functional performance in patients with HF.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Estado de Salud / Encuestas y Cuestionarios / Insuficiencia Cardíaca / Actividades Humanas Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Estado de Salud / Encuestas y Cuestionarios / Insuficiencia Cardíaca / Actividades Humanas Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male / Middle aged Idioma: En Año: 2016 Tipo del documento: Article