Novel pure component contribution, mean centering of ratio spectra and factor based algorithms for simultaneous resolution and quantification of overlapped spectral signals: An application to recently co-formulated tablets of chlorzoxazone, aceclofenac and paracetamol.
Toubar, Safaa S; Hegazy, Maha A; Elshahed, Mona S; Helmy, Marwa I.
  • Toubar SS; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Ain Helwan, Cairo, Egypt.
  • Hegazy MA; Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo, Egypt. Electronic address: mahahgazy@yahoo.com.
  • Elshahed MS; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Ain Helwan, Cairo, Egypt.
  • Helmy MI; Analytical Chemistry Department, Faculty of Pharmacy, Helwan University, Ain Helwan, Cairo, Egypt.
Article en En | MEDLINE | ID: mdl-27038581
In this work, resolution and quantitation of spectral signals are achieved by several univariate and multivariate techniques. The novel pure component contribution algorithm (PCCA) along with mean centering of ratio spectra (MCR) and the factor based partial least squares (PLS) algorithms were developed for simultaneous determination of chlorzoxazone (CXZ), aceclofenac (ACF) and paracetamol (PAR) in their pure form and recently co-formulated tablets. The PCCA method allows the determination of each drug at its λmax. While, the mean centered values at 230, 302 and 253nm, were used for quantification of CXZ, ACF and PAR, respectively, by MCR method. Partial least-squares (PLS) algorithm was applied as a multivariate calibration method. The three methods were successfully applied for determination of CXZ, ACF and PAR in pure form and tablets. Good linear relationships were obtained in the ranges of 2-50, 2-40 and 2-30µgmL(-1) for CXZ, ACF and PAR, in order, by both PCCA and MCR, while the PLS model was built for the three compounds each in the range of 2-10µgmL(-1). The results obtained from the proposed methods were statistically compared with a reported one. PCCA and MCR methods were validated according to ICH guidelines, while PLS method was validated by both cross validation and an independent data set. They are found suitable for the determination of the studied drugs in bulk powder and tablets.