Your browser doesn't support javascript.
loading
The generation of amplified spontaneous emission in high-power CPA laser systems.
Keppler, Sebastian; Sävert, Alexander; Körner, Jörg; Hornung, Marco; Liebetrau, Hartmut; Hein, Joachim; Kaluza, Malte Christoph.
  • Keppler S; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany.
  • Sävert A; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany.
  • Körner J; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany.
  • Hornung M; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany; Helmholtz-Institute Jena Germany.
  • Liebetrau H; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany.
  • Hein J; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany; Helmholtz-Institute Jena Germany.
  • Kaluza MC; Institute of Optics and Quantum Electronics Friedrich-Schiller-University of Jena Germany; Helmholtz-Institute Jena Germany.
Laser Photon Rev ; 10(2): 264-277, 2016 03.
Article en En | MEDLINE | ID: mdl-27134684
An analytical model is presented describing the temporal intensity contrast determined by amplified spontaneous emission in high-intensity laser systems which are based on the principle of chirped pulse amplification. The model describes both the generation and the amplification of the amplified spontaneous emission for each type of laser amplifier. This model is applied to different solid state laser materials which can support the amplification of pulse durations ≤350 fs . The results are compared to intensity and fluence thresholds, e.g. determined by damage thresholds of a certain target material to be used in high-intensity applications. This allows determining if additional means for contrast improvement, e.g. plasma mirrors, are required for a certain type of laser system and application. Using this model, the requirements for an optimized high-contrast front-end design are derived regarding the necessary contrast improvement and the amplified "clean" output energy for a desired focussed peak intensity. Finally, the model is compared to measurements at three different high-intensity laser systems based on Ti:Sapphire and Yb:glass. These measurements show an excellent agreement with the model.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2016 Tipo del documento: Article