Comparison of immediate versus day to day variability of ventricular tachycardia induction by programmed stimulation.
Cooper, M J; Koo, C C; Skinner, M P; Mortensen, P T; Hunt, L J; Richards, D A; Uther, J B; Ross, D L.
  • Cooper MJ; Department of Medicine, Westmead Hospital, New South Wales, Australia.
J Am Coll Cardiol ; 13(7): 1599-607, 1989 Jun.
Article en En | MEDLINE | ID: mdl-2723272
Search on Google
Banco de datos: MEDLINE Asunto principal: Taquicardia / Estimulación Cardíaca Artificial / Sistema de Conducción Cardíaco Tipo de estudio: Guideline / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 1989 Tipo del documento: Article