Your browser doesn't support javascript.
loading
Electrochemiluminescence (ECL) immunosensor for detection of Francisella tularensis on screen-printed gold electrode array.
Spehar-Délèze, Anna-Maria; Julich, Sandra; Gransee, Rainer; Tomaso, Herbert; Dulay, Samuel B; O'Sullivan, Ciara K.
  • Spehar-Délèze AM; Departament d'Enginyeria Quimica, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007, Tarragona, Spain. annamaria.spehar@gmail.com.
  • Julich S; Institute of Bacterial Infections and Zoonoses, Friedrich-Loeffer-Institut, Naumburger Str. 96A, 07743, Jena, Germany.
  • Gransee R; Fraunhofer ICT-IMM, Carl-Zeiss-Strasse 18-20, 55129, Mainz, Germany.
  • Tomaso H; Institute of Bacterial Infections and Zoonoses, Friedrich-Loeffer-Institut, Naumburger Str. 96A, 07743, Jena, Germany.
  • Dulay SB; Departament d'Enginyeria Quimica, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007, Tarragona, Spain.
  • O'Sullivan CK; Departament d'Enginyeria Quimica, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007, Tarragona, Spain. ciara.osullivan@urv.cat.
Anal Bioanal Chem ; 408(25): 7147-53, 2016 Oct.
Article en En | MEDLINE | ID: mdl-27255102
ABSTRACT
An electrochemiluminescence (ECL) immunosensor for the rapid detection of the Francisella tularensis pathogen using whole antibodies or antibody fragments as capture biomolecule is described. A sandwich immunoassay was used with either lipopolysaccharide (LPS) or the whole inactivated bacterial cell (LVS) as a target, while Ru(bpy)3 (2+)-encapsulated silicate nanoparticles were linked to the secondary antibody and used as ECL labels. The assay was performed in a fluidic chip housed in a custom-built black box incorporating electronics, optics and fluidics. The obtained limit of detection for LPS was 0.4 ng/mL, while for the LVS it was 70 and 45 bacteria/mL when the capturing molecule was the whole antibody and the antibody F(ab) fragment, respectively.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Inmunoensayo / Anticuerpos Inmovilizados / Técnicas Electroquímicas / Francisella tularensis / Oro / Mediciones Luminiscentes / Anticuerpos Antibacterianos Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Inmunoensayo / Anticuerpos Inmovilizados / Técnicas Electroquímicas / Francisella tularensis / Oro / Mediciones Luminiscentes / Anticuerpos Antibacterianos Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Año: 2016 Tipo del documento: Article