Your browser doesn't support javascript.
loading
The effect of using components from different manufacturers on the rate of wear and corrosion of the head-stem taper junction of metal-on-metal hip arthroplasties.
Whittaker, R K; Hothi, H S; Meswania, J M; Berber, R; Blunn, G W; Skinner, J A; Hart, A J.
  • Whittaker RK; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
  • Hothi HS; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
  • Meswania JM; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
  • Berber R; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
  • Blunn GW; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
  • Skinner JA; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
  • Hart AJ; Institute of Orthopaedics and Musculoskeletal Science, University College London and London Implant Retrieval Centre (LIRC), Biomedical Engineering, Royal National Orthopaedic Hospital, Stanmore, HA7 4LP, UK.
Bone Joint J ; 98-B(7): 917-24, 2016 Jul.
Article en En | MEDLINE | ID: mdl-27365469
ABSTRACT

AIMS:

Surgeons have commonly used modular femoral heads and stems from different manufacturers, although this is not recommended by orthopaedic companies due to the different manufacturing processes. We compared the rate of corrosion and rate of wear at the trunnion/head taper junction in two groups of retrieved hips; those with mixed manufacturers (MM) and those from the same manufacturer (SM). MATERIALS AND

METHODS:

We identified 151 retrieved hips with large-diameter cobalt-chromium heads; 51 of two designs that had been paired with stems from different manufacturers (MM) and 100 of seven designs paired with stems from the same manufacturer (SM). We determined the severity of corrosion with the Goldberg corrosion score and the volume of material loss at the head/stem junction. We used multivariable statistical analysis to determine if there was a significant difference between the two groups.

RESULTS:

We found no significant difference in the corrosion scores of the two groups. The median rate of material loss at the head/stem junction for the MM and SM groups were 0.39 mm(3)/year (0.00 to 4.73) and 0.46 mm(3)/year (0.00 to 6.71) respectively; this difference was not significant after controlling for confounding factors (p = 0.06).

CONCLUSION:

The use of stems with heads of another manufacturer does not appear to affect the amount of metal lost from the surfaces between these two components at total hip arthroplasty. Other surgical, implant and patient factors should be considered when determining the mechanisms of failure of large diameter metal-on-metal hip arthroplasties. Cite this article Bone Joint J 2016;98-B917-24.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Diseño de Prótesis / Falla de Prótesis / Artroplastia de Reemplazo de Cadera / Corrosión / Prótesis Articulares de Metal sobre Metal / Prótesis de Cadera Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Diseño de Prótesis / Falla de Prótesis / Artroplastia de Reemplazo de Cadera / Corrosión / Prótesis Articulares de Metal sobre Metal / Prótesis de Cadera Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2016 Tipo del documento: Article