Your browser doesn't support javascript.
loading
New insight into monitoring degradation products during the TiO2-photocatalysis process by multivariate molecular spectroscopy.
Stets, Sandra; do Amaral, Bianca; Bach, Larissa; Nagata, Noemi; Peralta-Zamora, Patricio G.
  • Stets S; Chemistry Department, Universidade Federal do Paraná, Av. Francisco H. dos Santos, s/n, Jardim das Américas, CP 19032, Curitiba, Paraná, 81531-980, Brazil. sandrastets@gmail.com.
  • do Amaral B; Chemistry Department, Universidade Federal do Paraná, Av. Francisco H. dos Santos, s/n, Jardim das Américas, CP 19032, Curitiba, Paraná, 81531-980, Brazil.
  • Bach L; Chemistry Department, Universidade Federal do Paraná, Av. Francisco H. dos Santos, s/n, Jardim das Américas, CP 19032, Curitiba, Paraná, 81531-980, Brazil.
  • Nagata N; Chemistry Department, Universidade Federal do Paraná, Av. Francisco H. dos Santos, s/n, Jardim das Américas, CP 19032, Curitiba, Paraná, 81531-980, Brazil.
  • Peralta-Zamora PG; Chemistry Department, Universidade Federal do Paraná, Av. Francisco H. dos Santos, s/n, Jardim das Américas, CP 19032, Curitiba, Paraná, 81531-980, Brazil.
Environ Sci Pollut Res Int ; 24(7): 6040-6046, 2017 Mar.
Article en En | MEDLINE | ID: mdl-27448812
This study focuses on the feasibility of a spectroscopic multivariate method for monitoring the concentration of phenol and its main degradation products during heterogeneous photocatalysis. Phenolic compounds were chosen as model to evaluate the degradation process due to their toxicity and persistence in the environment and also their well-known degradation pathway. The predictive capability of the multivariate method developed by partial least squares regression (PLSR) over the spectral range of 200-350 nm was satisfactory, allowing mean predicted errors below 5.0 % in the simultaneous determination of the target compounds using six latent variables and smoothing spectra. Suitable results were reported for the simultaneous determination of hydroquinone, resorcinol, pyrocatechol, and p-benzoquinone in accordance to the chromatographic method. Characteristics such as simplicity, low cost, and fast data acquisition are remarkable in this procedure, which makes it appropriate for this type of analytical control.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fenoles / Titanio / Modelos Químicos Tipo de estudio: Prognostic_studies Idioma: En Año: 2017 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Fenoles / Titanio / Modelos Químicos Tipo de estudio: Prognostic_studies Idioma: En Año: 2017 Tipo del documento: Article