Your browser doesn't support javascript.
loading
Assessment of the feasibility of using transrectal ultrasound for postimplant dosimetry in low-dose-rate prostate brachytherapy.
Davies, Rhian Siân; Perrett, Teresa; Powell, Jane; Barber, Jim; Tanguay, Jacob; Button, Michael; Cochlin, Dennis; Smith, Christian; Lester, Jason Francis.
  • Davies RS; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK. Electronic address: rhian.s.davies@wales.nhs.uk.
  • Perrett T; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Powell J; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Barber J; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Tanguay J; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Button M; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Cochlin D; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Smith C; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Lester JF; Department of Clinical Oncology, Velindre Cancer Centre, Cardiff, Wales, UK.
Med Dosim ; 41(4): 290-295, 2016.
Article en En | MEDLINE | ID: mdl-27623391
A study was performed to establish whether transrectal ultrasound (TRUS)-based postimplant dosimetry (PID) is both practically feasible and comparable to computed tomography (CT)-based PID, recommended in current published guidelines. In total, 22 patients treated consecutively at a single cancer center with low-dose-rate (LDR) brachytherapy for early-stage prostate cancer had a transrectal ultrasound performed immediately after implant (d0-TRUS) and computed tomography scan 30 days after implant (d30-CT). Postimplant dosimetry planning was performed on both image sets and the results were compared. The interobserver reproducibility of the transrectal ultrasound postimplant dosimetry planning technique was also assessed. It was noticed that there was no significant difference in mean prostate D90 (136.5Gy and 144.4Gy, p = 0.2197), V100 (86.4% and 89.1%, p = 0.1480) and V150 (52.0% and 47.8%, p = 0.1657) for d30-CT and d0-TRUS, respectively. Rectal doses were significantly higher for d0-TRUS than d30-CT. Urethral doses were available with d0-TRUS only. We have shown that d0-TRUS PID is a useful tool for assessing the quality of an implant after low-dose-rate prostate brachytherapy and is comparable to d30-CT PID. There are clear advantages to its use in terms of resource and time efficiency both for the clinical team and the patient.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Recto / Braquiterapia Tipo de estudio: Diagnostic_studies / Etiology_studies / Guideline Límite: Humans / Male Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Recto / Braquiterapia Tipo de estudio: Diagnostic_studies / Etiology_studies / Guideline Límite: Humans / Male Idioma: En Año: 2016 Tipo del documento: Article