Your browser doesn't support javascript.
loading
Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion.
Chang, Jun-Dong; Kim, In-Sung; Prabhakar, Sharad; Mansukhani, Sameer A; Lee, Sang-Soo; Yoo, Je-Hyun.
  • Chang JD; Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea.
  • Kim IS; Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea.
  • Prabhakar S; Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea.
  • Mansukhani SA; Department of Orthopaedic Surgery, Hallym University Dongtan Sacred Heart Hospital, Hwaseong-si, Gyeonggi-do, Republic of Korea.
  • Lee SS; Department of Orthopaedic Surgery, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon, Republic of Korea.
  • Yoo JH; Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang, Republic of Korea.
J Arthroplasty ; 32(5): 1576-1580, 2017 05.
Article en En | MEDLINE | ID: mdl-28139342
ABSTRACT

BACKGROUND:

The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.

METHODS:

A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the "safe zone."

RESULTS:

The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.

CONCLUSION:

Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Desviación Ósea / Artroplastia de Reemplazo de Cadera / Cirugía Asistida por Computador / Prótesis de Cadera Tipo de estudio: Etiology_studies / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2017 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Desviación Ósea / Artroplastia de Reemplazo de Cadera / Cirugía Asistida por Computador / Prótesis de Cadera Tipo de estudio: Etiology_studies / Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2017 Tipo del documento: Article