Your browser doesn't support javascript.
loading
Transverse Coherence Limited Coherent Diffraction Imaging using a Molybdenum Soft X-ray Laser Pumped at Moderate Pump Energies.
Zürch, M; Jung, R; Späth, C; Tümmler, J; Guggenmos, A; Attwood, D; Kleineberg, U; Stiel, H; Spielmann, C.
  • Zürch M; Institute of Optics and Quantum Electronics, Abbe Center of Photonics, Friedrich Schiller University Jena, Max-Wien-Platz 1, 07743, Jena, Germany. mwz@berkeley.edu.
  • Jung R; University of California Berkeley, Chemistry Department, Berkeley, CA, 94720, USA. mwz@berkeley.edu.
  • Späth C; Helmholtz Institute Jena, Fröbelstieg 3, 07743, Jena, Germany. mwz@berkeley.edu.
  • Tümmler J; Max-Born Institute, Max-Born Str. 2A, D-12489, Berlin, Germany.
  • Guggenmos A; Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748, Garching, Germany.
  • Attwood D; Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Str. 1, D-85748, Garching, Germany.
  • Kleineberg U; Max-Born Institute, Max-Born Str. 2A, D-12489, Berlin, Germany.
  • Stiel H; Ludwig-Maximilians-Universität München, Am Coulombwall 1, D-85748, Garching, Germany.
  • Spielmann C; Max-Planck-Institut für Quantenoptik, Hans-Kopfermann-Str. 1, D-85748, Garching, Germany.
Sci Rep ; 7(1): 5314, 2017 07 13.
Article en En | MEDLINE | ID: mdl-28706258
Coherent diffraction imaging (CDI) in the extreme ultraviolet has become an important tool for nanoscale investigations. Laser-driven high harmonic generation (HHG) sources allow for lab scale applications such as cancer cell classification and phase-resolved surface studies. HHG sources exhibit excellent coherence but limited photon flux due poor conversion efficiency. In contrast, table-top soft X-ray lasers (SXRL) feature excellent temporal coherence and extraordinary high flux at limited transverse coherence. Here, the performance of a SXRL pumped at moderate pump energies is evaluated for CDI and compared to a HHG source. For CDI, a lower bound for the required mutual coherence factor of |µ 12| ≥ 0.75 is found by comparing a reconstruction with fixed support to a conventional characterization using double slits. A comparison of the captured diffraction signals suggests that SXRLs have the potential for imaging micron scale objects with sub-20 nm resolution in orders of magnitude shorter integration time compared to a conventional HHG source. Here, the low transverse coherence diameter limits the resolution to approximately 180 nm. The extraordinary high photon flux per laser shot, scalability towards higher repetition rate and capability of seeding with a high harmonic source opens a route for higher performance nanoscale imaging systems based on SXRLs.