Your browser doesn't support javascript.
loading
Computed tomography characteristics of the aortic valve and the geometry of SAPIEN 3 transcatheter heart valve in patients with bicuspid aortic valve disease.
Kawamori, Hiroyuki; Yoon, Sung-Han; Chakravarty, Tarun; Maeno, Yoshio; Kashif, Mohammad; Israr, Sharjeel; Abramowitz, Yigal; Mangat, Geeteshwar; Miyasaka, Masaki; Rami, Tanya; Kazuno, Yoshio; Takahashi, Nobuyuki; Jilaihawi, Hasan; Nakamura, Mamoo; Cheng, Wen; Friedman, John; Berman, Daniel; Sharma, Rahul; Makkar, Raj R.
  • Kawamori H; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Yoon SH; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Chakravarty T; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Maeno Y; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Kashif M; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Israr S; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Abramowitz Y; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Mangat G; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Miyasaka M; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Rami T; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Kazuno Y; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Takahashi N; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Jilaihawi H; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Nakamura M; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Cheng W; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Friedman J; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Berman D; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Sharma R; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
  • Makkar RR; Cedars-Sinai Medical Center, Heart Institute, 127 S.San Vincente Boulevard, Los Angeles, CA, USA.
Eur Heart J Cardiovasc Imaging ; 19(12): 1408-1418, 2018 12 01.
Article en En | MEDLINE | ID: mdl-29315371
ABSTRACT

Aims:

We assessed the geometry of transcatheter heart valve (THV) and valve function associated with SAPIEN 3 implantation in patients with bicuspid aortic valve (BAV) stenosis. Methods and

results:

We included 280 consecutive patients who had a contrast computed tomography (CT) before and after transcatheter aortic valve implantation (TAVI) in our institution. Each THV was assessed by CT at five cross-sectional levels inflow, annulus, mid, sinus, and outflow. The geometry of THV was assessed for eccentricity (1 - minimum diameter/maximum diameter) and expansion (CT derived external valve area/nominal external valve area). CT measurements and transthoracic echocardiogram data were compared between BAV and tricuspid aortic valve (TAV). Among 280 patients, 41 patients were diagnosed as BAV. Compared to TAV, BAV was associated with lower expansion at mid-level, sinus-level, and outflow-level (mid 94.1 ± 6.8% vs. 98.1 ± 7.8%; P = 0.002, sinus 95.9 ± 7.2% vs. 101.6 ± 8.5%; P < 0.001, outflow 107.6 ± 6.2% vs. 109.9 ± 6.6%; P = 0.043), and higher eccentricity at all levels [inflow 3.5% (1.9-5.3) vs. 6.0% (3.2-7.5); P < 0.001, annulus 3.1% (1.6-5.2) vs. 5.4% (3.1-7.8); P = 0.002, mid 3.0% (1.4-4.9) vs. 6.0% (3.3-10.4); P < 0.001, sinus 3.0% (1.7-5.1) vs. 7.6% (4.0-11.4); P < 0.001, and outflow 2.5% (1.3-4.3) vs. 4.9% (2.2-7.5); P < 0.001]. There were no differences in frequency of paravalvular leak ≥ moderate and mean post-procedural gradient between BAV and TAV.

Conclusion:

BAV patients have greater THV eccentricity at all levels and lower THV expansion at mid, sinus, and outflow levels than the TAV patients. There were no differences in parameters of valve function between BAV and TAV patients. Despite the observed geometrical differences, TAVI with SAPIEN 3 in BAV patients allows for feasible valve function.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Complicaciones Posoperatorias / Tomografía Computarizada por Rayos X / Reemplazo de la Válvula Aórtica Transcatéter / Enfermedades de las Válvulas Cardíacas Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Válvula Aórtica / Estenosis de la Válvula Aórtica / Complicaciones Posoperatorias / Tomografía Computarizada por Rayos X / Reemplazo de la Válvula Aórtica Transcatéter / Enfermedades de las Válvulas Cardíacas Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Female / Humans / Male Idioma: En Año: 2018 Tipo del documento: Article