Your browser doesn't support javascript.
loading
The Marburg-Münster Affective Disorders Cohort Study (MACS): A quality assurance protocol for MR neuroimaging data.
Vogelbacher, Christoph; Möbius, Thomas W D; Sommer, Jens; Schuster, Verena; Dannlowski, Udo; Kircher, Tilo; Dempfle, Astrid; Jansen, Andreas; Bopp, Miriam H A.
  • Vogelbacher C; Department of Psychiatry and Psychotherapy, University Marburg, Marburg, Germany; Marburg Center for Mind, Brain and Behavior (MCMBB), Marburg, Germany.
  • Möbius TWD; Institute of Medical Informatics and Statistics, Kiel University, Kiel, Germany.
  • Sommer J; Core-Unit Brainimaging, Faculty of Medicine, University Marburg, Marburg, Germany; Marburg Center for Mind, Brain and Behavior (MCMBB), Marburg, Germany.
  • Schuster V; Department of Psychiatry and Psychotherapy, University Marburg, Marburg, Germany; Marburg Center for Mind, Brain and Behavior (MCMBB), Marburg, Germany.
  • Dannlowski U; Department of Psychiatry and Psychotherapy, University Münster, Münster, Germany.
  • Kircher T; Department of Psychiatry and Psychotherapy, University Marburg, Marburg, Germany; Marburg Center for Mind, Brain and Behavior (MCMBB), Marburg, Germany.
  • Dempfle A; Institute of Medical Informatics and Statistics, Kiel University, Kiel, Germany.
  • Jansen A; Department of Psychiatry and Psychotherapy, University Marburg, Marburg, Germany; Core-Unit Brainimaging, Faculty of Medicine, University Marburg, Marburg, Germany; Marburg Center for Mind, Brain and Behavior (MCMBB), Marburg, Germany. Electronic address: jansena2@staff.uni-marburg.de.
  • Bopp MHA; Department of Psychiatry and Psychotherapy, University Marburg, Marburg, Germany; Department of Neurosurgery, University Marburg, Marburg, Germany; Marburg Center for Mind, Brain and Behavior (MCMBB), Marburg, Germany.
Neuroimage ; 172: 450-460, 2018 05 15.
Article en En | MEDLINE | ID: mdl-29410079
ABSTRACT
Large, longitudinal, multi-center MR neuroimaging studies require comprehensive quality assurance (QA) protocols for assessing the general quality of the compiled data, indicating potential malfunctions in the scanning equipment, and evaluating inter-site differences that need to be accounted for in subsequent analyses. We describe the implementation of a QA protocol for functional magnet resonance imaging (fMRI) data based on the regular measurement of an MRI phantom and an extensive variety of currently published QA statistics. The protocol is implemented in the MACS (Marburg-Münster Affective Disorders Cohort Study, http//for2107.de/), a two-center research consortium studying the neurobiological foundations of affective disorders. Between February 2015 and October 2016, 1214 phantom measurements have been acquired using a standard fMRI protocol. Using 444 healthy control subjects which have been measured between 2014 and 2016 in the cohort, we investigate the extent of between-site differences in contrast to the dependence on subject-specific covariates (age and sex) for structural MRI, fMRI, and diffusion tensor imaging (DTI) data. We show that most of the presented QA statistics differ severely not only between the two scanners used for the cohort but also between experimental settings (e.g. hardware and software changes), demonstrate that some of these statistics depend on external variables (e.g. time of day, temperature), highlight their strong dependence on proper handling of the MRI phantom, and show how the use of a phantom holder may balance this dependence. Site effects, however, do not only exist for the phantom data, but also for human MRI data. Using T1-weighted structural images, we show that total intracranial (TIV), grey matter (GMV), and white matter (WMV) volumes significantly differ between the MR scanners, showing large effect sizes. Voxel-based morphometry (VBM) analyses show that these structural differences observed between scanners are most pronounced in the bilateral basal ganglia, thalamus, and posterior regions. Using DTI data, we also show that fractional anisotropy (FA) differs between sites in almost all regions assessed. When pooling data from multiple centers, our data show that it is a necessity to account not only for inter-site differences but also for hardware and software changes of the scanning equipment. Also, the strong dependence of the QA statistics on the reliable placement of the MRI phantom shows that the use of a phantom holder is recommended to reduce the variance of the QA statistics and thus to increase the probability of detecting potential scanner malfunctions.
Asunto(s)
Palabras clave

Texto completo: 1 Ejes tematicos: Pesquisa_clinica Banco de datos: MEDLINE Asunto principal: Garantía de la Calidad de Atención de Salud / Imagen por Resonancia Magnética / Estudios Multicéntricos como Asunto / Neuroimagen Tipo de estudio: Clinical_trials / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Ejes tematicos: Pesquisa_clinica Banco de datos: MEDLINE Asunto principal: Garantía de la Calidad de Atención de Salud / Imagen por Resonancia Magnética / Estudios Multicéntricos como Asunto / Neuroimagen Tipo de estudio: Clinical_trials / Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Límite: Adult / Female / Humans / Male Idioma: En Año: 2018 Tipo del documento: Article