Your browser doesn't support javascript.
loading
Coracoid graft union: a quantitative assessment by computed tomography in primary and revision Latarjet procedure.
Samim, Mohammad; Small, Kirstin M; Higgins, Laurence D.
  • Samim M; Department of Radiology, NYU Langone Medical Center, New York, NY, USA.
  • Small KM; Department of Radiology, Brigham and Women's Hospital, Boston, MA, USA. Electronic address: ksmall1@bwh.harvard.edu.
  • Higgins LD; Boston Shoulder Institute, Boston, MA, USA.
J Shoulder Elbow Surg ; 27(8): 1475-1482, 2018 Aug.
Article en En | MEDLINE | ID: mdl-29477667
ABSTRACT

BACKGROUND:

The goal of the Latarjet procedure is restoration of shoulder stability enabled by accurate graft positioning and union. This study aimed to establish a reproducible method of quantitatively assessing coracoid graft osseous union percentage (OUP) using computed tomography (CT) scans and to determine the effect of other factors on the OUP. MATERIALS AND

METHODS:

Postoperative CT scans of 41 consecutive patients treated with the open Latarjet procedure (37% primary, 63% revision) for anterior glenohumeral instability were analyzed for the OUP, position of the graft, and screw type and angle. Two musculoskeletal radiologists independently examined the images 2 times, and intraobserver and interobserver reliability was calculated using intraclass correlation coefficient (ICC).

RESULTS:

Mean OUP was 66% (range, 0%-94%) using quantitate methods, with good intraobserver reliability (ICC = 0.795) and interobserver reliability (ICC = 0.797). Nonunion and significant graft resorption was found in 2 patients. No significant difference was found in the mean OUP in the primary (63%) vs. revision Latarjet procedure (67%). Grafts were flush in 39%, medial in 36%, and lateral in 8%. The medial and neutral graft position was associated with slightly higher OUP (72% and 69%) compared with lateral (65%). OUP was higher when the superior screw angle was less than 17° and the inferior screw angle was less than 24°. This difference did not reach statistical significance. Screw type was not associated with significant difference in OUP.

CONCLUSION:

Quantitative assessment of osseous union of the graft using a reproducible method that we introduced showed similar OUP in the primary and revision Latarjet procedure.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Osteogénesis / Articulación del Hombro / Transferencia Tendinosa / Apófisis Coracoides Límite: Adult / Female / Humans / Male Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Osteogénesis / Articulación del Hombro / Transferencia Tendinosa / Apófisis Coracoides Límite: Adult / Female / Humans / Male Idioma: En Año: 2018 Tipo del documento: Article